Eaton Crouse-Hinds EDS215 OP CL Pushbutton Control Station - Hazardous/Classified Locations

Part Number: EDS215 OP CL
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDS215 OP CL

Quick Summary

EDS pushbutton control station provides rugged, reliable control for hazardous-area equipment. Facility teams often grapple with downtime and unsafe interlocks in Class I/II locations, making durability and clear signaling critical. This unit carries NEC/CEC compliance and UL explosionproof certifications, along with hazardous-location area classifications, delivering proven safety and reliability. With a 600 Vac rating and feraloy iron alloy construction, it supports long-term operation in demanding environments while simplifying installation and maintenance. By pairing two pushbuttons and a compact single-gang enclosure with a 3/4" trade size, it aligns with modern industrial control architectures and minimizes panel space without compromising safety or performance.

Product Information

Extended Description

EDS215 OP CL Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Open, Close, Feraloy iron alloy, Two circuit, 2, Single-gang, 2, Dead end, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS215 OP CL
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
3.65 lb
UPC
662276211087
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class II, Division 2 Class III Class I, Division 2
NEMA Rating
9 3 7
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit
Indicating plate markings
Open, Close
Style
Dead end
Trade size
3/4"
Material
Feraloy iron alloy
Feature: 600 Vac voltage rating ensures compatibility with high-power equipment in hazardous locations. Impact: Enables direct integration with motor controllers and other heavy-load devices, reducing the need for step-down transformers and associated losses. Application: Oil & gas, chemicals, and mining facilities where high voltage control is standard. Feature: Two pushbuttons with two devices in a single-gang enclosure. Impact: Simplifies control logic, enables clear start/stop or open/close actions, and reduces wiring complexity. Application: Emergency stop and process-start sequences in explosion-protected stations. Feature: Feraloy iron alloy enclosure and explosionproof design. Impact: Enhances mechanical robustness and resistance to arc tracking and impact, lowering replacement costs and downtime. Application: Deployment in harsh plants and outdoor hazardous areas. Feature: Open/Close indicating plates. Impact: Improves operator visibility and interlock accuracy, minimizing misoperation and startup errors. Application: Hazardous-location panels requiring explicit status signaling. Feature: NEC/CEC compliance and NEMA 9 3 7 ratings with UL certifications. Impact: Ensures regulatory adherence, simplifies audits, and reduces risk of non-compliance penalties. Application: Facilities needing certified equipment for Class I, II, and III locations. Feature: Compact dimensions (3/4" trade size, 5.91" height, 5.81" width, 3.5" depth). Impact: Facilitates easy retrofit and panel-mace integration without excessive footprint. Application: Upgrades to existing hazardous-location control cabinets with limited space. Feature: Material and construction are designed for long service life in demanding environments. Impact: Lower total cost of ownership through less frequent maintenance and fewer part replacements. Application: Continuous-process plants and remote facilities where reliability is essential.

Get a Quick Quote for a Eaton Crouse-Hinds EDS215 OP CL

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDS215 OP CL? Enquire Now

FAQs

The EDS215 OP CL is designed for Class I/II/III hazardous locations and features a single-gang enclosure, 3/4 inch trade size, and Open/Close indicating plates. Installers should follow NEC/CEC guidelines, secure proper grounding, and ensure connections meet 600 Vac ratings. The compact footprint simplifies mounting in retrofit panels and minimizes field wiring.
Key specs include a 600 Vac voltage rating, two pushbuttons, two devices, and a single-gang enclosure. The unit uses a 3/4" trade size with a feraloy iron alloy body, providing robust protection. It is suitable for direct 600 Vac control circuits in hazardous locations and supports open/close signaling for clear operator feedback.
Yes. The EDS215 OP CL is rated for Hazardous/Classified Locations under NEC/CEC standards and carries UL explosionproof certification. Its construction and approvals cover Class I Division 1 and 2, Class II Division 1 and 2, and Class III environments, making it appropriate for a wide range of hazardous industrial applications.
The unit carries NEC/CEC standards compliance, UL certification for explosionproof operation in hazardous locations, and a NEMA rating listed as 9, 3, 7. It is designed for Hazardous/Classified Locations, ensuring regulatory alignment and audit readiness in critical plants.
The combination of explosionproof construction, durable feraloy alloy, and compact single-gang design reduces maintenance cycles and downtime in hazardous environments. Clear Open/Close signaling minimizes misoperation, while NEC/CEC compliance lowers regulatory risk, delivering lower lifecycle costs and improved plant safety over time.