Eaton EDR-3000-2C0HA0 Distribution Relay - 61850/DNP3
Part Number: EDR-3000-2C0HA0
Quick Summary
The Eaton distribution relay EDR-3000-2C0HA0 provides reliable feeder protection and metering for industrial power systems. Users often struggle with integrating multiple communication protocols and scalable protection in demanding environments. Compliances are listed as 'Contact Manufacturer' in the data sheet, so verify certifications such as CE, UL and SIL with Eaton for regulatory alignment. This solution supports open standards including 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet, while offering a flexible power input range of 19–300 VDC and 40–250 VAC. For feeders in manufacturing plants, data centers, or substations, it combines robust protection with straightforward integration, helping reduce downtime and simplify commissioning at remote sites.
Product Information
Extended Description
EDR-3000-2C0HA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4,Feeder, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz ,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C0HA0
UPC
786679142196
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Eaton Specification Sheet - EDR-3000-2C0HA0
Feature: Open communication options including 61850, Mbus TCP, and DNP3 TCP/UDP over Enet RJ45. Business Impact: Simplifies integration with SCADA, analytics, and control systems, reducing engineering time and commissioning costs. Application: Feeder protection networks and substation automation where interoperability is essential. Feature: Wide power supply range of 19-300 VDC and 40-250 VAC. Business Impact: Flexible deployment across diverse plant environments without additional power conditioning. Application: Industrial feeders in manufacturing, water treatment, and utilities where voltage variety is common. Feature: Four inputs and four outputs with removable terminals. Business Impact: Streamlined field wiring and fast installation with reliable fault isolation. Application: Feeder interlocking, control logic, and metering in compact panels. Feature: Current sensing inputs and Zone Selective Interlocking (1). Business Impact: Enhanced protective coordination and faster fault clearing, minimizing impact on healthy feeders. Application: Large-scale motor and line protection schemes in plants. Feature: IRIG-B timing option and IRIG-B compatible I/O. Business Impact: Precise time synchronization for coordinated protection and event logging. Application: Data centers and critical facilities where timing accuracy matters. Feature: Semi-flush mounting and removable terminals. Business Impact: Easier installation, maintenance, and panel integration with reduced downtime. Application: Retrofit projects and new builds requiring flexible hardware attachment. Feature: 50/60 Hz compatibility and 5A/1A phase current rating. Business Impact: Accurate metering and protection across common utility frequencies, improving reliability and compliance. Application: feeders powering diverse loads in industrial environments. Feature: 1-year warranty (or 18 months from shipment as per policy). Business Impact: Predictable support window and risk mitigation for procurement planning. Application: Long-term asset management and maintenance budgeting.
Get a Quick Quote for a Eaton EDR-3000-2C0HA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2C0HA0?
Enquire Now
FAQs
Begin by mounting the unit using the semi-flush method and securing removable terminals for wiring. Connect power within the 19–300 VDC or 40–250 VAC range, then assign the four input and four output channels to your feeder protection scheme. For communication, terminate Ethernet RJ45 to support 61850, Mbus TCP, or DNP3 TCP/UDP. Use IRIG-B where timing precision is required and verify the zone interlocking setting to optimize fault clearance.
Key specs include the 50/60 Hz frequency rating and the broad power range (19–300 VDC, 40–250 VAC) to ensure compatibility in varied facilities. The device provides four inputs and four outputs with one current-sensing input, enabling current protection and metering. Ethernet-based protocols (61850, Mbus TCP, DNP3 TCP/UDP) simplify SCADA integration and remote diagnostics.
Yes. It is designed for feeder protection and metering with four inputs and four outputs, zone selective interlocking, and a current sensing input for protection accuracy. The power range supports diverse plant voltage levels, and Ethernet-based protocols enable modern substation integration. Compatibility with IRIG-B timing and removable terminals helps with reliable field deployment and maintenance.
The datasheet lists compliances as 'Contact Manufacturer', so verify with Eaton for CE, UL, SIL, and IP ratings relevant to your installation. Confirm timing, protection class, and environmental ratings, and ensure the unit meets your plant’s regulatory and safety standards before deployment.
The EDR-3000-2C0HA0 reduces downtime through robust protection, modular wiring, and open-standards communication. The semi-flush mounting and removable terminals simplify service, while a one-year warranty (or 18 months from shipment) provides a clear support window. Long-term ROI comes from fewer field faults, easier integration, and reduced commissioning time.