Eaton EDR-3000-2C0LA0 Distribution Relay - 50/60 Hz

Part Number: EDR-3000-2C0LA0
Manufacturer
Eaton
Part number
EDR-3000-2C0LA0

Quick Summary

Eaton distribution relay EDR-3000-2C0LA0 provides reliable feeder protection for industrial electrical networks. Engineers often need to integrate multi-technology protection in compact spaces while maintaining robust communications with fieldbus protocols. Compliance details are listed as 'Contact Manufacturer' in this dataset, so verify CE, SIL, and IP ratings directly with Eaton to ensure regulatory alignment. The unit supports a wide power range from 19–300 Vdc or 40–250 Vac at 50/60 Hz and offers four inputs with four removable outputs, plus optional IRIG-B time sync and fiber-based communications for SCADA integration. This combination translates to greater system reliability and shorter commissioning cycles for feeders.

Product Information

Extended Description

EDR-3000-2C0LA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, 19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C0LA0
UPC
786679140765
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
1
I/O options
IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Powering flexibility, the EDR-3000-2C0LA0 accepts 19-300 Vdc or 40-250 Vac with 50/60 Hz, enabling deployment across plants with diverse power architectures. This broad voltage range reduces the need for multiple converters, lowers BOM costs, and simplifies spare-part inventories in mixed-voltage facilities such as chemical plants or metal fabrication shops. The four inputs and four removable outputs simplify wiring, enable rapid on-site testing, and reduce downtime while the semi-flush mounting helps fit into tight panels; removable terminals speed replacement and testing, and zone-selective interlocking (1) improves coordination in multi-feeder runs for selective tripping and reduced outages. Communication options include Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Enet, with Modbus/DNP3 TCP compatibility for SCADA integration and optional IRIG-B time synchronization for precise metering and event logging. Sensing inputs enable current protection and metering with phase currents selectable at 5A or 1A, supporting accurate protection coordination and fast fault isolation. The combination of capability and form factor supports easier installations, faster project delivery, and lower maintenance costs in busy industrial environments. The unit weighs 5.3 lb and measures 7.49 in L × 8.62 in H × 6.82 in W, designed to fit standard feeder enclosures with removable terminals for straightforward retrofits and serviceability. Warranty terms extend for one year from installation or 18 months from shipment, aligning with Eaton’s service policy and providing reassurance during critical commissioning phases.

Get a Quick Quote for a Eaton EDR-3000-2C0LA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2C0LA0? Enquire Now

FAQs

Install the EDR-3000-2C0LA0 by mounting it with the semi-flush method in a suitable enclosure. Use the removable terminals to ease wiring and testing, then connect the four inputs and four outputs per your feeder protection scheme. Power the unit from the range 19-300Vdc or 40-250Vac and configure 50/60 Hz. Plan the fiber optic link for Mbus TCP or DNP3 TCP/UDP communications and enable IRIG-B if time synchronization is required.
EDR-3000-2C0LA0 supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet, plus Modbus/DNP3 TCP bridging for integration with SCADA and EMS. The optional IRIG-B time synchronization enhances precise timestamping for metering and event logging, enabling accurate coordination across protection schemes.
Yes. The relay provides a current sensing input and dedicated protection/metering functions ideal for zone selective interlocking in large feeders. It supports phase currents of 5A and 1A and includes Zone Selective Interlocking (ZSI) capability to enable coordinated trips, improving reliability and reducing fault propagation in multi-feeder configurations.
Dimensions are 7.49 inches in length, 8.62 inches in height, and 6.82 inches in width, with a weight of 5.3 pounds. It uses a semi-flush mounting method and has removable terminals for rapid wiring changes and testing. Designed for feeder cabinets with space constraints, it offers wiring flexibility and straightforward retrofit opportunities.
Warranty is one year from installation or eighteen months from shipment, whichever occurs first. Compliance details are listed as 'Contact Manufacturer'; verify CE, SIL, IP ratings, and any regional certifications with Eaton to ensure regulatory alignment, proper documentation for audits, and maintenance planning.