Eaton transformer relay is a transformer protection relay designed for monitoring and controlling power systems in industrial plants. For engineers and maintenance teams, unreliable transformer protection or slow fault isolation can lead to costly outages. Certification notes: Compliance information is provided by the manufacturer; typical approvals for Eaton relays include CE marking and SIL-rated protection, with conformal coating on circuit boards to withstand harsh environments. The product supports Profibus-DP over fiber and a wide input range, enabling flexible integration with modern control architectures. In practice, this device delivers reliable protection while enabling efficient asset management, with strong compatibility for substation upgrades and OEM equipment in industrial automation.
Product Information
Extended Description
ETR-5000-2A0DB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A0DB0
UPC
786679155608
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B URTD Interface
Phase current
5A, 1A
PROFIBUS-DP
over fiber optic ST
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A0DB0
Selling Policy 25-000 - Distribution and Control Products and Services
Eight digital inputs, two current-sensing inputs, and nine outputs provide a versatile I/O backbone for the unit. This dense I/O reduces external wiring, shortens installation time, and accelerates fault detection, improving protection reliability for transformers in substations or OEM equipment. Wide power supply range of 19-300 Vdc and 40-250 Vac at 50/60 Hz supports mixed voltage environments, reducing inventory and wiring complexity while enabling seamless integration with existing plant power. Removable terminals and semi-flush mounting simplify field servicing and retrofits, cutting downtime during maintenance or upgrades. Profibus-DP over fiber optic ST delivers robust, noise-immune communication for PLCs and SCADA systems in harsh environments, enabling reliable control and monitoring across the network. IO options such as Trip Coil Monitor, IRIG‑B, and URTD Interface extend diagnostics and time synchronization, supporting precise protection coordination in complex plants. Sensing inputs include Voltage Protection and Metering, Differential Protection, Current Protection and Metering, and Power Protection and Metering, delivering broad protection coverage with accurate metering for asset management. Zone Selective Interlocking supports two zones to improve selectivity and minimize outage impact in feeder protection schemes. Conformal coating on circuit boards enhances reliability in harsh environments, making the unit suitable for outdoor enclosures and rugged installations. The combination of these features reduces risk, improves reliability, and supports compliant protection strategies in modern transformer protection architectures.
Get a Quick Quote for a Eaton ETR-5000-2A0DB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A0DB0?
Enquire Now
FAQs
Begin by mounting the unit in a semi-flush position with the removable terminals accessible. Connect the 8 digital inputs, 2 current-sensing inputs, and 9 outputs according to your protection scheme, then power the device from 19-300 Vdc or 40-250 Vac. Verify Profibus-DP over fiber optic ST link to your PLC, and calibrate protection thresholds using the manufacturer's spec sheet.
The fiber optic channel provides noise-immune, secure communication for high‑speed data exchange with PLCs and SCADA systems, reducing communication errors in industrial environments. This enables reliable monitoring, remote trip commands, and coordinative protection strategies across transformer assets.
Yes. The relay supports a wide power supply range of 19-300 Vdc and 40-250 Vac at 50/60 Hz, allowing it to operate within mixed electrical environments without requiring multiple power supplies or extra adapters. This simplifies installation and reduces spare parts requirements.
The unit offers Voltage Protection and Metering, Differential Protection, Current Protection and Metering, and Power Protection and Metering. Combined with zone selective interlocking and time-synchronization options, it delivers comprehensive transformer protection and precise fault localization across complex power networks.
Consider the removable terminals for easier field servicing, conformal coating for rugged environments, and the extensive I/O and networking options that reduce external hardware. These features lower maintenance time and improve uptime, contributing to a favorable total cost of ownership through reduced diagnostics, faster fault isolation, and longer asset life.