Eaton JGX3225FAGC Complete MCCB - UL Listed, 600 Vac
Part Number: JGX3225FAGC
Quick Summary
Eaton JGX3225FAGC complete molded case circuit breaker protects industrial power circuits and motor loads. Maintenance teams often face nuisance trips and uneven protection across panels. This device carries CSA Certified, IEC Rated, and UL Listed certifications, with CE marking for global compliance. Built on the Series G platform, it provides 225 A at 600 Vac with 50/60 Hz operation and metric mounting for straightforward panel integration, delivering reliable protection for control cabinets and machinery.
Product Information
Extended Description
JGX3225FAGC Eaton: Eaton Series G molded case circuit breaker, JG-frame, JG, Fixed thermal, adjustable magnetic trip, Three-pole, 225A, 600 Vac, 200 kAIC at 240 Vac, 200 kAIC at 480 Vac, 50 kAIC at 600 Vac, Line and load, Metric, 50/60 Hz, 100% rated
Product Name
Eaton Series G complete molded case circuit breaker
Catalog Number
JGX3225FAGC
UPC
786685581712
Product Length/Depth
3.57 in
Product Height
4.13 in
Product Width
4.13 in
Product Weight
6 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
CE Marked
Certifications
CSA Certified IEC Rated UL Listed
Type
Complete breaker
Amperage Rating
225 A
Voltage rating
600 Vac
Trip Type
T185
Circuit breaker type
JG
Circuit breaker frame type
Complete breaker
Rating
100% rated
Series
Series G
Terminals
Line and load
Frame
JG
Frequency rating
50 to 60 Hz
Mounting hardware
Metric
Interrupt rating
50 kAIC at 600 Vac 200 kAIC at 480 Vac 200 kAIC at 240 Vac
Number of poles
Three-pole
Application of Tap Rules to Molded Case Breaker Terminals
Application of Tap Rules to Molded Case Breaker Terminals
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
High performance operating handles for Series G circuit breakers product aid
Breaker service centers
Circuit Protection, Molded Case Circuit Breakers, Volume 4, Tab 2
MOEM MCCB product selection guide
MOEM MCCB product selection guide
MOEM MCCB product selection guide
Feature: 225 A amperage rating supports robust load handling with a compact footprint. Business Impact: Reduces panel crowding while maintaining high current carrying capability, enabling safer, more reliable starter protection for motors and feeders. Application: Ideal for control panels and motor control centers in manufacturing environments. Feature: 3-pole design with line and load terminals. Business Impact: Simplifies wiring, improves coordination, and strengthens protection across three-phase circuits. Application: Suitable for power distribution blocks and machine power feeds in heavy industry. Feature: 600 Vac voltage rating with 50/60 Hz compatibility. Business Impact: Enables compatibility with global electrical systems and reduces the need for multiple devices. Application: Widely used in international panel builds and cross-border projects. Feature: T185 trip type, fixed thermal, adjustable magnetic trip. Business Impact: Delivers precise overcurrent protection and fast fault response, minimizing equipment damage. Application: Critical for motors, pumps, and conveyor drives. Feature: 200 kAIC interrupt ratings at 240/480 Vac and 50 kAIC at 600 Vac. Business Impact: High fault current tolerance supports safer outages and reduced upstream protection coordination costs. Application: Essential in high-energy environments like extrusion, stamping, and large machine lines. Feature: Series G framing (JG), complete breaker with standard metric mounting. Business Impact: Streamlines procurement and installation, improving serviceability and spare-part availability. Application: Best suited for standardized electrical protection across multiple panels and locations.
Get a Quick Quote for a Eaton JGX3225FAGC
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton JGX3225FAGC?
Enquire Now
FAQs
Yes. The JGX3225FAGC uses line and load terminals and features metric mounting hardware, designed for straightforward integration into standard panels and enclosures. Ensure correct terminal torque per manufacturer guidelines and align with Series G mounting practices to preserve interrupt reliability.
The device is a three-pole MCCB rated for 225 A at 600 Vac, with a T185 trip type and fixed thermal, adjustable magnetic trip. It supports 50/60 Hz operation and offers interrupt ratings up to 200 kAIC at 240/480 Vac, ensuring robust protection against overloads and short circuits.
Yes. The unit is CE marked and UL Listed, with CSA Certified and IEC rated certifications, reflecting broad regulatory compliance. This combination supports global deployments in machinery, panels, and control systems while meeting recognized safety standards.
It is well-suited for motor control centers, machine power distribution, and control panels in manufacturing environments. The three-pole arrangement, high interrupt capability, and fixed/adjustable trip allow reliable protection for motors, conveyors, and power feeds across 50/60 Hz systems.