Eaton S38D11P02PXCE Transformer - UL Listed

Part Number: S38D11P02PXCE
Manufacturer
Eaton
Part number
S38D11P02PXCE

Quick Summary

Eaton S38D11P02PXCE transformer provides reliable power conversion for general distribution in industrial settings. Engineers often face space constraints, mounting challenges, and voltage stability when expanding control panels, and a compact, robust solution is essential. It carries UL Listed certification and CE marking for global compliance, with a rugged NEMA 3R enclosure that supports indoor-outdoor installations. With a 2 kVA rating, 380 V primary, and taps for ±2.5% regulation, it offers built-in voltage adjustment, while aluminum windings and a compact footprint deliver cost-effective, dependable performance for panel builders and machine integrators.

Product Information

Extended Description

S38D11P02PXCE Eaton: Eaton, general purpose encapsulated transformer, ep, single-phase, pv: 380v, taps: 2 at +2.5% fcan, 2 at -2.5% fcbn, sv: 120/240v, 115°c, 2 kva, al windings, frame: 68p, indoor-outdoor.
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S38D11P02PXCE
UPC
786680090936
Product Length/Depth
6.32 in
Product Height
13.78 in
Product Width
6 in
Product Weight
44 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
50/60 Hz, CE Marked
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
68P
Tap size
2 at +2.5% FCAN, 2 at -2.5% FCBN
Type
General-Purpose Encapsulated Transformer
Wiring connection
Hold
Frequency rating
50-60 Hz
Phase
Single-phase
Primary voltage
380 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
2 kVA
Weathershield
Indoor-Outdoor
Feature → Business Impact → Application: The S38D11P02PXCE is a single-phase, general-purpose encapsulated transformer rated at 2 kVA with a 380 V primary and 120/240 V secondary, built with aluminum windings and a 50-60 Hz operating range. This combination translates to efficient power transfer in compact enclosures, reducing panel depth and allowing easier wire routing in control cabinets and distributed power circuits. Application: ideal for machine feeders and panel boards where space is at a premium and reliability matters. Feature → Business Impact → Application: Voltage taps of 2 at +2.5% and 2 at -2.5% FCAN/FCBN enable precise voltage regulation in environments with fluctuating mains, decreasing equipment downtime and enhancing control stability. Application: production lines and remote sites with variable supply. Feature → Business Impact → Application: NEMA 3R enclosure with an indoor-outdoor rating (Weathershield: Indoor-Outdoor) provides rugged protection against weather and dust, enabling versatile installation across plant floors and outdoor cabinets. Application: outdoor-rated panels and sensor cabinets. Feature → Business Impact → Application: 68P frame, 6.32 in length, 6 in width, 13.78 in height, and 44 lb weight offer a compact, easy-to-mount package that streamlines installation and reduces shipping and handling costs. Application: retrofit projects and new builds with tight space budgets. Feature → Business Impact → Application: UL Listed, CE Marked, 50/60 Hz operation, and a 1-year warranty (or 18 months from shipment) provide regulatory assurance and predictable maintenance planning, lowering risk for compliance audits and long-term asset management. Application: global deployments in diverse markets. Feature → Business Impact → Application: Aluminum coil material and epoxy encapsulation improve thermal performance and durability, lowering the need for frequent rework in high-heat environments and enabling reliable operation in demanding industrial settings. Application: harsh factory floors and equipment enclosures. Feature → Business Impact → Application: 2 kVA rating supports modest power needs across multiple devices in control panels, enabling scalable design without overspecifying transformers. Application: expansions or future-proofing of power distribution in manufacturing lines.

Get a Quick Quote for a Eaton S38D11P02PXCE

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S38D11P02PXCE? Enquire Now

FAQs

Place the 2 kVA transformer in a compliant enclosure with adequate ventilation. Its NEMA 3R rating supports indoor-outdoor placement, while the 68P frame and 6.32 in L × 6 in W × 13.78 in H footprint simplify mounting in standard panels. Ensure wiring follows local codes, use the specified taps for voltage regulation, and respect the 50-60 Hz operating range to maintain performance.
The transformer provides two positive and two negative taps, allowing +/- 2.5% adjustment to the primary 380 V. This helps compensate for mains fluctuations, stabilizing the 120/240 V secondary output. In practice, this reduces nuisance tripping, improves sensor and controller accuracy, and minimizes the need for downstream voltage conditioning in dynamic plant environments.
Yes. With an indoor-outdoor Weathershield designation and a rugged NEMA 3R enclosure, the unit is designed for reliable operation in varied environments. Aluminum windings and encapsulation enhance heat dispersion and moisture resistance, while the compact form factor facilitates mounting in outdoor cabinets or protected outdoor installations alongside indoor panels.
The S38D11P02PXCE is UL Listed and CE Marked, confirming compliance with global electrical safety and performance standards. It operates at 50-60 Hz and delivers 2 kVA, with a single-phase configuration and a 380 V primary paired to 120/240 V secondary, making it suitable for multinational deployments and regulated environments.
The transformer carries a warranty of one year from installation or 18 months from shipment, whichever occurs first, backed by Eaton's service policy. With aluminum windings, a robust encapsulated build, and a durable enclosure, maintenance is typically minimal—fewer leak points and stable performance—supporting predictable total cost of ownership and reliable long-term uptime.