014U0001

Part Number: 014U0001
Manufacturer
Danfoss
Part number
014U0001

Product Information

Extended Description

014U0001 Danfoss: Energy meter for residential applications
Gross weight
0.887 Kilogram
Net weight
0.7 Kilogram
Volume
3.108 Liter
EAN
5702425128912
1 Primary battery SUM weight Kg
0.018
1 Primary battery weight Kg
0.018
Accuracy standard
Class 2 to EN1434
Ambient class
E1 / M2
Ambient humidity [% RH] [Max]
95 %
Ambient temperature [=C2=B0C] [max]
55 =C2=B0C
Ambient temperature [=C2=B0C] [min]
5 =C2=B0C
Application
Heating
Approval authority
Force Certification
Approved meteorological range [=C2=B0C] [Max]
95 =C2=B0C
Approved meteorological range [=C2=B0C] [Min]
5 =C2=B0C
Battery lifetime [Years]
16 yr
Battery qty
1
Battery type or Name
AA Lithium
Cable insulation material
PVC halogen free
Cable length between calculator and flow sensor [m]
0.5 m
China RoHS compliance
Out of scope
Commissioning tool
SonoApp
Connection size
G 3/4
Connection types
Thread
Contain batteries
Yes
Description
Energy meter for residential applications
Diameter [mm]
15 mm
Difference temperature limits (Accounting) [K] [Max]
90 K
Difference temperature limits (Accounting) [K] [Min]
3 K
Display type
LCD
Dynamic range
1:100
EEE category
5 small equipment (any external dimension 50 cm)
Energy unit
kWh (without digit after comma)
EU RoHS compliance
Out of scope
Flow measuring principle
Ultrasonic
Housing color
RAL 9010 White
In scope of WEEE
Yes
Installation
Return
Integrated communication
No integrated communication
Interface module slot 1
No interface module
IP protection class
IP65
Kvs values [m=C2=B3/h]
3.46 m=C2=B3/h
Length [mm]
110 mm
Log storage duration [Month]
24 mo
Log storage interval [Month]
1 mo
Material in contact with medium
Brass sensor
Media
Heating system according to VDI 2035
Media temperature [=C2=B0C] [Max]
95 =C2=B0C
Media temperature [=C2=B0C] [Min]
5 =C2=B0C
Pressure nominal [bar]
16 bar
Product group
Energy meters
Protection class calculator
IP65
qc [m=C2=B3/h]
0.0012 m=C2=B3/h
qi [m=C2=B3/h]
0.006 m=C2=B3/h
qp [m=C2=B3/h]
0.6 m=C2=B3/h
qs [m=C2=B3/h]
1.2 m=C2=B3/h
qss [m=C2=B3/h]
1.32 m=C2=B3/h
REACH Candidate List substances
Lead (CAS no. 7439-92-1)
SCIP dossier no.
c284e070-c802-4ced-837c-2aa2fcd3510f
SCIP dossier product name
Ultrasonic Pathfinder
Storage temperature [=C2=B0C] [Max]
60 =C2=B0C
Storage temperature [=C2=B0C] [Min]
-25 =C2=B0C
Supply voltage [V] DC
4 V
Supply voltage type
Battery 1 A-cell
Temperature sensor approved temperature [=C2=B0C] [Max]
105 =C2=B0C
Temperature sensor approved temperature [=C2=B0C] [Min]
0 =C2=B0C
Temperature sensor diameter [mm]
5.2 mm
Temperature sensors cable length [m]
1.5 m
Temperature sensors type
Pt 1000
Type
SonoSafe 10
UK RoHS compliance
Out of scope
Weight per battery
18 g

Get a Quick Quote for a Danfoss 014U0001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Danfoss 014U0001? Enquire Now