ABB MC2C310ATWJ Mini Contactor - 110 V DC Coil, UL/CE

Part Number: 1SAL102381R9902
Manufacturer
ABB
Part number
1SAL102381R9902

Quick Summary

The ABB MC2C310ATWJ Mini Contactor provides DC coil control for three-phase loads in compact switchgear. In panel enclosures where space is tight, you need reliable operation without sacrificing wiring simplicity or serviceability. It complies with IEC 60947-1 and 60947-4-1, UL 60947-1/60947-4-1, and CE/UKCA declarations, ensuring global compatibility and regulatory peace of mind. With screw terminals, one NO auxiliary contact, and DIN-rail mounting, it streamlines installation and reduces wiring errors, delivering measurable productivity gains. For controls in building automation or industrial equipment, its 110 V DC coil, 20 A Ie rating, and space-saving footprint make it a practical, cost-effective choice.

Product Information

Extended Description

1SAL102381R9902 ABB: The MC2C310ATWJ mini contactor is a dimension optimized 3 pole contactor with 1 NO auxiliary contact and screw terminals. This device is a great solution when high performances are needed but the space is limited. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. The product is equipped with an extended operating limits coil and it's suitable for wall or rail mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Chapter 4 (InDesign) - Main catalog Motor Protection and control
Instructions and Manuals
Installation Instructions - M Mini Contactor, Mini Contactor Relay
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
68 mm
Product Net Height
48 mm
Product Net Weight
0.25 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | UL 60947-5-1
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 440 V DC | Main Circuit 690 V AC | Main Circuit 440 V DC
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC | Control Circuit DC | Main Circuit 50 Hz | Main Circuit 60 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit 10 A | Main Circuit 20 A
Rated Operational Current AC-1 (Ie)
(690 V) 55 °C 20 A | (690 V) 70 °C 16 A | (230 V) 55 °C 20 A | (230 V) 70 °C 16 A | (400 V) 55 °C 20 A | (400 V) 70 °C 16 A | (500 V) 55 °C 20 A | (500 V) 70 °C 16 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 12 A | (400 V) 55 °C 12 A | (500 V) 55 °C 10 A | (690 V) NO 55°C 5 A
Rated Operational Current AC-15 (Ie)
(240 V) 6 A | (400 V) 4 A | (500 V) 2.5 A | (690 V) 1.5 A
Rated Operational Current DC-13 (Ie)
(24 V) 5 A | (48 V) 2.5 A | (125 V) 0.55 A | (250 V) 0.3 A | (440 V) 0.15 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW | (400 V) Three Phase 5.5 kW | (500 V) Three Phase 5.5 kW | (690 V) Three Phase, NO 4 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui)
750 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV | Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-15) 360 cycles per hour | (AC-3) 1200 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 360 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
110 V DC
Coil Consumption
Average Holding Value DC 4 W | Average Pull-in Value DC 4 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.7 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible 1/2x 0.75 ... 2.5 mm² | Rigid 1x 0.75 ... 4 mm² | Rigid 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible 1/2x 0.75 ... 2.5 mm² | Rigid 1x 0.75 ... 4 mm² | Rigid 2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Control Circuit 9 mm | Main Circuit 9 mm
Degree of Protection
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Recommended Screw Driver
Pozidriv 2
Tightening Torque
Auxiliary Circuit 0.8 ... 1.0 N·m | Control Circuit 0.8 N·m | Main Circuit 0.8 ... 1.0 N·m
Terminal Type
Screw Terminals
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(600 V AC) 20 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.5 Hp | (200 V AC) Three Phase 3 Hp | (220 ... 240 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 2 Hp | (440 ... 480 V AC) Three Phase 7.5 Hp | (550 ... 600 V AC) Three Phase 10 Hp
Connecting Capacity Main Circuit UL/CSA
Stranded 1/2x 18-12 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Stranded 1/2x 18-12 AWG
Contact Rating UL/CSA
A600 | Q600
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb | Control Circuit 7 in·lb | Main Circuit 7 in·lb
Full Load Amps Motor Use
(115 V AC) Single Phase 9.8 A | (200 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (230 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Operation -40 ... +70 °C | Storage -55 ... +80 °C
Maximum Operating Altitude Permissible
3000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations
5g 3 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – IEC
A2L Certificate - MC1, MC2, MCR, MACL, MACR series - Mini Contactors
BV Certificate
BV Certificate - MC1, MC2, MCR, MACL, MACR - Mini Contactors
CB Certificate
CB Certificate - MC1, MC2 - Mini Contactors
CQC Certificate
CQC Certificate, Mini Contactor, MC1, MC2, MC1…-RAIL, MC2…-RAIL, Made in Bulgaria
Declaration of Conformity - CCC
CCC Declaration of Conformity, Mini Contactor, MC1, MC2, MC1…-RAIL, MC2…-RAIL, Made in Bulgaria
Declaration of Conformity - CE
EU Declaration of Conformity - MC1, MC2, MCR,MACL, MARL,MACN, MARN, MP0, MMH0, WKMIU, MVB0R, MVB0L, MVP0C, BEMC - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - MC1, MC2, MCR,MACL, MARL,MACN, MARN, MP0, MMH0, WKMIU, MVB0R, MVB0L, MVP0C, BEMC - Mini Contactor
RINA Certificate
RINA Certificate - MC2, MACN, MACL, MARN, MARL - Mini Contactors
UL Certificate
UL Certificate of Compliance - MC1 (Pin), MC2 (Pin) - Mini Contactor
Package Level 1 Units
box 1 piece
Package Level 1 Width
46 mm
Package Level 1 Depth / Length
49 mm
Package Level 1 Height
70 mm
Package Level 1 Gross Weight
0.255 kg
Package Level 1 EAN
4013614545146
Package Level 2 Units
box 10 piece
Package Level 2 Width
243 mm
Package Level 2 Depth / Length
106 mm
Package Level 2 Height
80 mm
Package Level 2 Gross Weight
2.61 kg
Package Level 2 EAN
4013614545443
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
E-Number (Finland)
3709578
Feature: 3-pole design with 3 NO main contacts and 1 NO auxiliary contact. Business Impact: Enables reliable switching of three-phase motor loads while reducing the number of devices in the control circuit. Application: Suitable for compact motor control in commercial and light industrial panels. The ABB MC2C310ATWJ delivers enhanced control with minimal panel footprint, improving installation efficiency and wiring clarity. Feature → Business Impact → Application: 110 V DC coil operation reduces control wiring complexity in DC control schemes, enabling easier integration with PLCs and safety relays in both retrofit and new installs. Feature → Business Impact → Application: Screw terminals provide durable, versatile wiring connections for flexible conductor types, cutting termination time and minimizing loose connections in harsh environments. Feature → Business Impact → Application: DIN rail mounting TH35 allows rapid panel integration and standardized enclosure layouts across facilities. Feature → Business Impact → Application: IP20 protection on terminals and robust mechanical durability support long service life in commercial buildings and light industry. Feature → Business Impact → Application: High mechanical durability of 10,000,000 cycles reduces replacement costs and downtime in continuous operation environments. Feature → Business Impact → Application: Rated AC-3 power capabilities, up to 5.5 kW at 400 V and 12 A at 230 V, enable efficient motor starting and load switching with lower energy waste. Feature → Business Impact → Application: Compliance with IEC/UL/CE marks provides assurance for global markets and streamlined procurement across multi-region projects. Feature → Business Impact → Application: DIN mounting and compact dimensions help integrate with existing control panels, minimizing retrofits and enabling scalable automation architecture.

Get a Quick Quote for a ABB 1SAL102381R9902

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SAL102381R9902? Enquire Now

FAQs

The MC2C310ATWJ supports on-DIN-rail mounting using TH35-15 or TH35-7.5 rails and is equipped with screw terminals for main, auxiliary, and control circuits. Wire termination is designed for flexible and rigid conductors within the specified cross-sections, with a recommended tightening torque of 0.8 to 1.0 N·m to ensure reliable connections and vibration resistance in industrial environments.
Main circuit provides 3 normally open main contacts with a 20 A rated operational current at up to 690 V auxiliary circuits; auxiliary circuit includes 1 normally open contact. Rated operational power for AC-3 is 3 kW at 230 V, 5.5 kW at 400 V, and 5.5 kW at 500 V, while DC ratings support 110 V coil control with appropriate DC continuous operation parameters.
Yes. The device is a three-pole mini contactor designed for AC-3 and DC control scenarios, suitable for motor-start and load switching in commercial buildings and light industrial equipment. Its 20 A Ie rating at common voltages, compact footprint, and DIN-rail mounting simplify panel design, improve efficiency, and support reliable motor control in space-constrained assemblies.
The MC2C310ATWJ carries CE and UKCA declarations, UL/UL CSA certifications, and additional approvals such as CB, BV, CQC, CCC, and CCC, along with RoHS and REACH compliance. This broad certification set enables global deployment across Europe, North America, and other regions, reducing the need for re-qualifications on multinational projects.
With a mechanical durability rating of 10 million cycles and low coil power consumption (4 W holding, 4 W pull-in for DC operation), the MC2C310ATWJ minimizes maintenance and energy usage. Its robust IP20 terminal protection, screw-terminal design, and reliable screw connections reduce downtime and extend service life in demanding environments.