ABB 1SAM201910R1001 Motor Starters enable remote tripping for AA1 shunt release in industrial motor control. The first sentence demonstrates the primary keyword and core function within a concise description. Power fluctuations and accidental trips challenge uptime; this device helps avoid unplanned shutdowns by precise voltage thresholds. It is certified to CE conformity, UL/CSA recognition, and third‑party approvals (DNV GL, BV, ABS), supporting global compliance for safety‑critical installations. Designed for MS116, MS132, and MS165 families, it integrates with 20–24 V control schemes while aligning with ABB protection and control ecosystems to deliver reliable motor protection and streamlined maintenance across diverse applications.
Product Information
Extended Description
1SAM201910R1001 ABB: Shunt trips AA1 release manual motor starters used for remote tripping. They are attached laterally on the left side of MS116, MS132 or MS165. In accordance with IEC 60947-1, the manual motor starter is switched off by AA1 if the supply voltage of the shunt trip measured during the tripping operation remains between 70% and 110% of the rated control circuit supply voltage.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions - Manual Motor Starter MS116 | Installation Instructions - Manual Motor Starter magnetic only MO132 MO132-B | Installation Instructions - Manual Motor Starter MS132 MS132-B | Installation Instructions - MS132-K, MS132-KB Manual Motor Starter | Installation Instructions - Manual Motor Starter MS165 MS165-B | Installation Instructions - Manual Motor Starter magnetic only MO165 MO165-B
Instructions and Manuals (Part 3)
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
18 mm
Product Net Height
90 mm
Product Net Depth / Length
75.5 mm
Product Net Weight
0.1 kg
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
132.5 W
Terminal Type
Screw Terminals
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Auxiliary Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Auxiliary Circuit 10 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Standards
CSA 22.2 No. 14 | IEC/EN 60947-1 | IEC/EN 60947-4-1 | UL 508 | UL 60947-1 | UL 60947-4-1
Remarks
Please consider 15 min OFF-period after 5s ON-period. | The mechanical and electrical durability of manual motor starters in combination with UA1/AA1 is reduced. Values are provided on request.
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 16-12 AWG | Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb
Ambient Air Temperature
Operation -25 ... +60 °C | Storage -50 ... +80 °C
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACh Declaration for all Manual Motor Starters
RoHS Information
RoHS II Declaration for all Manual Motor Starters
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Manual Motor starters
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate - MS132, MO132, HK1, HKF1,SK1, CK1, UA1, AA1 - Manual Motor Starter
BV Certificate
BV Certificate - MS165, MO165, UA1, AA1, HK1, HKF1, SK1, CK1 - Manual Motor Starter
cUL Certificate
cUL_E137861
Declaration of Conformity - CE
EU Declaration of Conformity - MS1x - Accessories for Manual Motor Starters
Declaration of Conformity - UKCA
UK Declaration of Conformity - MS1x - Accessories for Manual Motor Starters
DNV GL Certificate
DNV Certificate - MS132, MS132-K, MO132, HK1, HKF1,SK1, CK1, UA1, AA1
LR Certificate
1SAA963001-0502 | LR Certificate MS165, MO165
RINA Certificate
Rina Certificate - MS132, MO132, MS132-K, HK1, HK1-K, HKF1, HKF1-K,SK1, SK1-K, CK1, UA1, AA1
UL Certificate
UL_E137861
Package Level 1 Units
box 1 piece
Package Level 1 Width
93 mm
Package Level 1 Depth / Length
25 mm
Package Level 1 Height
80 mm
Package Level 1 Gross Weight
0.11 kg
Package Level 1 EAN
4013614343308
Package Level 2 Units
carton 80 piece
Package Level 2 Width
280 mm
Package Level 2 Depth / Length
395 mm
Package Level 2 Height
210 mm
Package Level 2 Gross Weight
9.175 kg
Package Level 2 EAN
4013614526046
Object Classification Code
Q
ETIM 4
EC002498 - Accessories for low-voltage switch technology
ETIM 5
EC001023 - Shunt release (for power circuit breaker)
ETIM 6
EC001023 - Shunt release (for power circuit breaker)
ETIM 7
EC001023 - Shunt release (for power circuit breaker)
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
eClass
V11.0 : 27370418
UNSPSC
39121601
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
E-Number (Finland)
3705824
E-Number (Norway)
4364016
Feature → Business Impact → Application: Mounting compatibility enables lateral attachment to MS116, MS132 or MS165, reducing installation time and wiring errors while preserving existing cabinet layouts in machine rooms and packaging lines. This translates to faster commissioning and lower field labor costs in retrofits and new builds. Feature → Business Impact → Application: 20–24 V DC shunt trip control with the AA1 mechanism ensures reliable remote tripping; the defined 70% to 110% operating window minimizes nuisance trips, boosting overall line availability in conveyors and process equipment. Feature → Business Impact → Application: IEC/UL compliance and multiple third‑party certificates support cross‑border deployments and customer audits, ensuring regulatory alignment for multi-site manufacturing. Feature → Business Impact → Application: Screw terminal connections with specified torque (0.8–1.2 N·m) and 10 mm wire strips provide robust, vibration‑tolerant wiring for harsh industrial environments. Feature → Business Impact → Application: The compact footprint (18 mm width, 90 mm height, 75.5 mm depth) fits compact control panels, enabling safer layouts without sacrificing performance in MS starter assemblies. Feature → Business Impact → Application: Ambient operating range (-25 to +60°C) and shock resistance (11 ms, 15 g) improve reliability in outdoor or harsh indoor settings, reducing maintenance intervals and extending equipment life.
Get a Quick Quote for a ABB 1SAM201910R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SAM201910R1001?
Enquire Now
FAQs
Yes. The AA1 shunt trip release is designed for lateral attachment to MS116, MS132, and MS165 manual motor starters, enabling remote tripping within ABB’s motor protection family.
The unit operates on a 20–24 V DC control circuit. Tripping occurs when the supply voltage remains within 70% to 110% of the rated control circuit voltage during tripping, ensuring reliable action without nuisance operation.
The product carries CE conformity and UL/CSA listings, with additional third‑party approvals including DNV GL, BV, ABS, RINA, LR, and UL certifications, supporting global regulatory compliance.
Connections use screw terminals with a tightening torque of 0.8–1.2 N·m. Wire stripping length for the auxiliary circuit is 10 mm, and recommended tooling includes a Pozidriv 2 screwdriver for secure, vibration‑resistant connections.
Remote tripping enhances safety and reduces downtime by enabling rapid, controlled shutdown of motors. The solution simplifies installation, supports regulatory compliance, and is compatible with ABB’s protection ecosystem, contributing to lower maintenance costs and faster ROI in manufacturing environments.