ABB 1SAM201910R1002 Shunt Trip is a remote-tripping accessory for manual motor starters in industrial control panels. This solution helps prevent unexpected outages by enabling safe shutdown during fault conditions, improving safety and uptime. It meets IEC/EN 60947-1 safety standards and is UL/CSA listed, with CE declarations and other certifications from DNV GL, LR, and RINA to support global deployments. Designed for straightforward installation alongside MS116, MS132 or MS165 starters, it delivers compact integration without major panel redesign. The combination of remote-tripping capability, robust certifications, and ABB compatibility delivers measurable value for efficiency, safety, and regulatory compliance in automation projects.

Product Information

Extended Description

1SAM201910R1002 ABB: Shunt trips AA1 release manual motor starters used for remote tripping. They are attached laterally on the left side of MS116, MS132 or MS165. In accordance with IEC 60947-1, the manual motor starter is switched off by AA1 if the supply voltage of the shunt trip measured during the tripping operation remains between 70% and 110% of the rated control circuit supply voltage.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions - Manual Motor Starter MS116 | Installation Instructions - Manual Motor Starter magnetic only MO132 MO132-B | Installation Instructions - Manual Motor Starter MS132 MS132-B | Installation Instructions - MS132-K, MS132-KB Manual Motor Starter | Installation Instructions - Manual Motor Starter MS165 MS165-B | Installation Instructions - Manual Motor Starter magnetic only MO165 MO165-B
Instructions and Manuals (Part 3)
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
18 mm
Product Net Height
90 mm
Product Net Depth / Length
75.5 mm
Product Net Weight
0.1 kg
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
48 W
Terminal Type
Screw Terminals
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Auxiliary Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Auxiliary Circuit 10 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Standards
CSA 22.2 No. 14 | IEC/EN 60947-1 | IEC/EN 60947-4-1 | UL 508 | UL 60947-1 | UL 60947-4-1
Remarks
Please consider 15 min OFF-period after 5s ON-period. | The mechanical and electrical durability of manual motor starters in combination with UA1/AA1 is reduced. Values are provided on request.
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 16-12 AWG | Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb
Ambient Air Temperature
Operation -25 ... +60 °C | Storage -50 ... +80 °C
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACh Declaration for all Manual Motor Starters
RoHS Information
RoHS II Declaration for all Manual Motor Starters
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Manual Motor starters
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate - MS132, MO132, HK1, HKF1,SK1, CK1, UA1, AA1 - Manual Motor Starter
BV Certificate
BV Certificate - MS165, MO165, UA1, AA1, HK1, HKF1, SK1, CK1 - Manual Motor Starter
cUL Certificate
cUL_E137861
Declaration of Conformity - CE
EU Declaration of Conformity - MS1x - Accessories for Manual Motor Starters
Declaration of Conformity - UKCA
UK Declaration of Conformity - MS1x - Accessories for Manual Motor Starters
DNV GL Certificate
DNV Certificate - MS132, MS132-K, MO132, HK1, HKF1,SK1, CK1, UA1, AA1
LR Certificate
1SAA963001-0502 | LR Certificate MS165, MO165
RINA Certificate
Rina Certificate - MS132, MO132, MS132-K, HK1, HK1-K, HKF1, HKF1-K,SK1, SK1-K, CK1, UA1, AA1
UL Certificate
UL_E137861
Package Level 1 Units
box 1 piece
Package Level 1 Width
93 mm
Package Level 1 Depth / Length
25 mm
Package Level 1 Height
80 mm
Package Level 1 Gross Weight
0.11 kg
Package Level 1 EAN
4013614343322
Package Level 2 Units
carton 80 piece
Package Level 2 Width
280 mm
Package Level 2 Depth / Length
395 mm
Package Level 2 Height
210 mm
Package Level 2 Gross Weight
9.175 kg
Package Level 2 EAN
4013614526053
Object Classification Code
Q
ETIM 4
EC002498 - Accessories for low-voltage switch technology
ETIM 5
EC001023 - Shunt release (for power circuit breaker)
ETIM 6
EC001023 - Shunt release (for power circuit breaker)
ETIM 7
EC001023 - Shunt release (for power circuit breaker)
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
eClass
V11.0 : 27370418
UNSPSC
39121601
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
E-Number (Finland)
3705825
E-Number (Norway)
4364017
Remote-tripping capability using a 110 V control circuit ensures rapid isolation of motor circuits in fault events, reducing exposure to arc flash and equipment damage. This is directly applicable to MS116, MS132 and MS165 manual motor starters in machine controls and distribution panels, delivering improved safety and system availability. The unit’s compact footprint, 18 mm width and 90 mm height with 75.5 mm depth, supports easy mid-plane integration and lateral mounting on the left side of the starter assembly, minimizing enclosure space requirements and wiring complexity. Screw terminals, with compatible ferrule wiring (0.75–2.5 mm² and 2× 0.75–1.5 mm² options), simplify field wiring and reduce installation time, while a tightening torque of 0.8–1.2 N·m ensures robust connections. Power loss of 48 W is acceptable for continuous operation without excessive heat buildup in typical panels. Operating in a wide ambient range of -25 to +60 °C, the device remains reliable in demanding environments. Compliance with IEC/EN safety standards and UL/CSA certifications supports regulatory adherence in diverse markets, while mounting compatibility with MS1x family accelerates installation planning and inventory management. Documentation such as datasheets, installation instructions, and CAD drawings enhances maintenance planning and future retrofits, reinforcing long-term total cost of ownership advantages.

Get a Quick Quote for a ABB 1SAM201910R1002

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SAM201910R1002? Enquire Now

FAQs

Install the device on the left side of the MS starter assembly as a lateral attachment per ABB installation instructions. Connect the 110 V control circuit to the screw terminals, ensuring a secure, polarity-correct connection. Use appropriate ferrules for 0.75–2.5 mm² conductors and tighten connections to 0.8–1.2 N·m. Confirm tripping occurs within the defined voltage window of 70–110% of the rated control circuit supply during operation.
Ensure a 110 V control circuit supply for the shunt trip, with auxiliary circuit insulation rated at Ui 690 V and Uimp of 6 kV. The unit supports 50 Hz, 60 Hz, and DC auxiliary circuits and uses screw terminals designed for flexible ferrule or insulated ferrule wiring in the 0.75–2.5 mm² range.
Yes. The device carries IEC/EN 60947-1 safety compatibility, UL/CSA listings, CE declarations, and additional certifications from DNV GL, LR, and RINA. These certifications support compliance with global electrical safety regimes and simplify approvals for industrial automation projects.
The shunt trip has a net width of 18 mm, height of 90 mm, depth of 75.5 mm, and a net weight of 0.1 kg. It operates from -25 to +60 °C ambient, and is designed for mounting positions 1 through 6. It uses screw terminals for robust field wiring and is suitable for constrained control cabinets.
ABB provides datasheets (Data Sheet 1SBC100214C0202), installation instructions for MS116, MS132, and MS165, CAD dimensional drawings, and product brochures. These resources support accurate planning, streamlined installation, and straightforward future retrofits or replacements.