ABB 1SAM201910R1003 Shunt Trip - IEC 60947-1 Certified

Part Number: 1SAM201910R1003
Manufacturer
ABB
Part number
1SAM201910R1003

Quick Summary

ABB 1SAM201910R1003 is a shunt trip accessory for remote tripping of manual motor starters used in industrial control panels. This solution supports safer shutdowns and minimizes fault-related downtime. The device complies with IEC/EN 60947-1 and UL 508 and UL 60947-1/4-1, with CE marking for European installations, and carries additional approvals for critical equipment to support global projects. Designed to integrate with ABB MS series starters, it attaches laterally on MS116, MS132, or MS165 to deliver reliable protection without cluttering the control cabinet. By standardizing control-circuit voltage and meeting RoHS/REACH requirements, it helps streamline procurement and maintenance while enabling easier CAD-based design workflows for panel builders and automation engineers.

Product Information

Extended Description

1SAM201910R1003 ABB: Shunt trips AA1 release manual motor starters used for remote tripping. They are attached laterally on the left side of MS116, MS132 or MS165. In accordance with IEC 60947-1, the manual motor starter is switched off by AA1 if the supply voltage of the shunt trip measured during the tripping operation remains between 70% and 110% of the rated control circuit supply voltage.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions - Manual Motor Starter MS116 | Installation Instructions - Manual Motor Starter magnetic only MO132 MO132-B | Installation Instructions - Manual Motor Starter MS132 MS132-B | Installation Instructions - MS132-K, MS132-KB Manual Motor Starter | Installation Instructions - Manual Motor Starter MS165 MS165-B | Installation Instructions - Manual Motor Starter magnetic only MO165 MO165-B
Instructions and Manuals (Part 3)
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
18 mm
Product Net Height
90 mm
Product Net Depth / Length
75.5 mm
Product Net Weight
0.1 kg
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
39 W
Terminal Type
Screw Terminals
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Auxiliary Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Auxiliary Circuit 10 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Standards
CSA 22.2 No. 14 | IEC/EN 60947-1 | IEC/EN 60947-4-1 | UL 508 | UL 60947-1 | UL 60947-4-1
Remarks
Please consider 15 min OFF-period after 5s ON-period. | The mechanical and electrical durability of manual motor starters in combination with UA1/AA1 is reduced. Values are provided on request.
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 16-12 AWG | Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb
Ambient Air Temperature
Operation -25 ... +60 °C | Storage -50 ... +80 °C
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACh Declaration for all Manual Motor Starters
RoHS Information
RoHS II Declaration for all Manual Motor Starters
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Manual Motor starters
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate - MS132, MO132, HK1, HKF1,SK1, CK1, UA1, AA1 - Manual Motor Starter
BV Certificate
BV Certificate - MS165, MO165, UA1, AA1, HK1, HKF1, SK1, CK1 - Manual Motor Starter
cUL Certificate
cUL_E137861
Declaration of Conformity - CE
EU Declaration of Conformity - MS1x - Accessories for Manual Motor Starters
Declaration of Conformity - UKCA
UK Declaration of Conformity - MS1x - Accessories for Manual Motor Starters
DNV GL Certificate
DNV Certificate - MS132, MS132-K, MO132, HK1, HKF1,SK1, CK1, UA1, AA1
LR Certificate
1SAA963001-0502 | LR Certificate MS165, MO165
RINA Certificate
Rina Certificate - MS132, MO132, MS132-K, HK1, HK1-K, HKF1, HKF1-K,SK1, SK1-K, CK1, UA1, AA1
UL Certificate
UL_E137861
Package Level 1 Units
box 1 piece
Package Level 1 Width
93 mm
Package Level 1 Depth / Length
25 mm
Package Level 1 Height
80 mm
Package Level 1 Gross Weight
0.11 kg
Package Level 1 EAN
4013614343346
Package Level 2 Units
carton 80 piece
Package Level 2 Width
280 mm
Package Level 2 Depth / Length
395 mm
Package Level 2 Height
210 mm
Package Level 2 Gross Weight
9.175 kg
Package Level 2 EAN
4013614526060
Object Classification Code
Q
ETIM 4
EC002498 - Accessories for low-voltage switch technology
ETIM 5
EC001023 - Shunt release (for power circuit breaker)
ETIM 6
EC001023 - Shunt release (for power circuit breaker)
ETIM 7
EC001023 - Shunt release (for power circuit breaker)
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
eClass
V11.0 : 27370418
UNSPSC
39121601
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
E-Number (Finland)
3705826
E-Number (Norway)
4364018
Remote trip capability enables safe, remote shutdown of motor starters during fault conditions, reducing downtime and risk in manufacturing lines. Compatibility with MS116, MS132 and MS165 minimizes wiring complexity while delivering reliable protection; installation is straightforward for panel builders, saving commissioning time and ensuring consistent protection. Electrical specifications, including 200–240V control circuit voltage and 690V insulation, support diverse control schemes and international installations, while screw terminals and defined torque ensure robust, vibration-resistant connections and long-term reliability. The unit’s compact footprint (18 mm wide, 90 mm high, 75.5 mm deep) and light weight (0.1 kg) simplify enclosure layouts and retrofit projects. Documentation, CAD drawings, and installation instructions streamline design workflows and help maintain regulatory compliance. RoHS, REACH, and CMRT declarations support responsible sourcing and supplier risk management.

Get a Quick Quote for a ABB 1SAM201910R1003

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SAM201910R1003? Enquire Now

FAQs

The shunt trip attaches laterally to the designated manuals on MS116, MS132, or MS165. Use screw terminals for the auxiliary circuit, tighten to 0.8–1.2 N·m, strip 10 mm, and ensure a 1–6 mounting position. Verify a 1 piece minimum order quantity and consult the installation instructions for panel-assembly guidance.
The unit is designed for a 200–240V control circuit and 690V insulation voltage. It supports 50 Hz, 60 Hz, and DC auxiliary circuits, with a rated impulse withstand of 6 kV, aligning with IEC/EN 60947-1 and UL requirements.
Yes. It is purpose-built as a remote tripping accessory for manual motor starters, enabling safe shutdown of motors during fault conditions and simplifying integration into motor protection and control schemes in automation panels.
Key certifications include IEC/EN 60947-1, UL 508, UL 60947-1, UL 60947-4-1, and CE marking. Additional approvals from DNV GL, LR, BV, RINA, ABS, UL CSA listings, REACH and RoHS compliance support global deployments.
The compact form factor and low power loss (39 W) reduce heat and enclosure space needs, lowering cooling costs. Its standardized installation and rich documentation shorten commissioning and maintenance cycles, improving uptime and delivering faster return on investment for motor-protection projects.