ABB AFC09-30-10-86 Contactor - IEC/UL 690V, 3P

Part Number: 1SBL131001R8610
Manufacturer
ABB
Part number
1SBL131001R8610

Quick Summary

AFC09-30-10-86 Contactor by ABB is a three-pole power switch for AC motor control applications. Engineers frequently battle coil voltage compatibility and wiring complexity in mixed-voltage control panels. It carries IEC/EN 60947-4-1, UL 60947-4-1 and CSA C22.2 conformity, with CE and UKCA markings for global compliance. In addition to robust electrical ratings, it offers compact DIN-rail mounting and easy expansion with add-on auxiliary contacts, delivering reliable operation and simplified wiring for modern control cabinets. This combination supports faster commissioning, reduced panel space, and lower installation costs, making it a practical choice for machine builders and maintenance teams alike.

Product Information

Extended Description

1SBL131001R8610 ABB: The AFC09-30-10-86 is a 3-pole - 690 V IEC or 600 V UL contactor with 1 N.O built-in auxiliary contact and Screw terminals, mainly controlling power circuits up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V AC UL and 25 A (AC-1) or 25 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 415 ... 440 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.298 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 Β°C 25 A | (690 V) 60 Β°C 25 A | (690 V) 70 Β°C 22 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 Β°C 9 A | (440 V) 60 Β°C 9 A | (500 V) 60 Β°C 9.5 A | (690 V) 60 Β°C 7 A | (380 / 400 V) 60 Β°C 9 A | (220 / 230 / 240 V) 60 Β°C 9 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 Β°C 9 A | (440 V) 60 Β°C 9 A | (500 V) 60 Β°C 9.5 A | (690 V) 60 Β°C 7 A | (380 / 400 V) 60 Β°C 9 A | (220 / 230 / 240 V) 60 Β°C 9 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 4 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 4 kW | (220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-3e (Pe)
(415 V) 4 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 4 kW | (220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-6b (Pe)
(400 / 415 V) 40 Β°C, 50 / 60 Hz 8.5 kvar | (400 / 415 V) 70 Β°C, 50 / 60 Hz 7 kvar | (400 / 415 V) 55 Β°C, 50 / 60 Hz 8.5 kvar | (500 / 550 V), 40 Β°C, 50 / 60 Hz 10.5 kvar | (500 / 550 V) 55 Β°C, 50 / 60 Hz 10.5 kvar | (500 / 550 V) 70 Β°C, 50 / 60 Hz 9 kvar | (690 V) 40 Β°C, 50 / 60 Hz 14.5 kvar | (690 V) 55 Β°C, 50 / 60 Hz 14.5 kvar | (690 V) 70 Β°C, 50 / 60 Hz 12 kvar
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 Β°C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 Β°C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 Β°C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 Β°C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 Β°C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV | Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-2 / AC-4) 300 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 VΒ·A | Average Pull-in Value 50 Hz 70 VΒ·A | Average Pull-in Value 60 Hz 66 VΒ·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mmΒ² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mmΒ² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mmΒ² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mmΒ² | Rigid 1/2x 1 ... 6 mmΒ²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mmΒ² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mmΒ² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mmΒ² | Rigid 1/2x 1 ... 2.5 mmΒ²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mmΒ² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mmΒ² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mmΒ² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mmΒ² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mmΒ² | Rigid 1/2x 1 ... 2.5 mmΒ²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 NΒ·m | Control Circuit 1.2 NΒ·m | Main Circuit 1.5 NΒ·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
NEMA Size
00
Continuous Current Rating NEMA
9 A
Horsepower Rating NEMA
(115 V AC) Single Phase 1/3 Hp | (200 V AC) Three Phase 1-1/2 Hp | (230 V AC) Single Phase 1 Hp | (230 V AC) Three Phase 1-1/2 Hp | (460 V AC) Three Phase 2 Hp | (575 V AC) Three Phase 2 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 2 hp | (220 ... 240 V AC) Three Phase 2 hp | (240 V AC) Single Phase 1-1/2 hp | (440 ... 480 V AC) Three Phase 5 hp | (550 ... 600 V AC) Three Phase 7-1/2 hp
Tightening Torque UL/CSA
Auxiliary Circuit 11 inΒ·lb | Control Circuit 11 inΒ·lb | Main Circuit 13 inΒ·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 7.8 A | (220 ... 240 V AC) Three Phase 6.8 A | (240 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 7.6 A | (550 ... 600 V AC) Three Phase 9 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 Β°C | Close to Contactor without Thermal O/L Relay -40 ... 70 Β°C | Close to Contactor for Storage -60 ... +80 Β°C | Near Contactor for Operation in Free Air -40 ... 70 Β°C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 Β°C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 Β°C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AFC09 ... AFC38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AFC09 ... AFC38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AFC09, AFC12, AFC16 3 or 4-pole contactors
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-Certificate of Compliance AFC09 ... AFC38 3-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.321 kg
Package Level 1 EAN
3471523013896
Package Level 3 Units
1296 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three-pole main contacts and one NO auxiliary contact deliver a compact, integrated switching solution. Business Impact: Reduces component count and wiring complexity while maintaining reliable control of motors and loads. Application: Suitable for conveyor drives, fans, and pump starters where space is at a premium. Feature: Coil control voltage range supports 50 Hz and 60 Hz systems (400...415 V / 415...440 V). Business Impact: Enables cross-site deployment with common coil supply, lowering inventory and spare parts costs. Application: Global manufacturing lines with mixed power networks. Feature: 690 V rated insulation and 25 A AC-1 / 9 A AC-3 ratings provide versatile load handling. Business Impact: Safe, compliant operation across a wide range of loads, reducing downtime due to undersized starters. Application: AC-1 and AC-3 motor control in medium-power drives. Feature: Screw terminals and compatibility with add-on accessories simplify wiring and future expansion. Business Impact: Faster installation, easier maintenance, and scalable control circuits. Application: Panel builders upgrading legacy cabinets. Feature: DIN rail mounting options TH35-15 or TH35-7.5 and compact footprint enable dense panel layouts. Business Impact: Maximizes cabinet real estate and simplifies retrofits. Application: Industrial automation panels with limited space. Feature: Low power loss per pole (0.8 W AC-1 / 0.1 W AC-3) and fast operate times (9–26 ms). Business Impact: Improves energy efficiency and switching reliability, enabling precise control and reduced heat in enclosures. Application: High-cycle applications requiring quick response. Feature: Robust environmental ratings and IP indicators for auxiliary and main terminals. Business Impact: Plant-wide reliability in varying temperatures and dusty environments. Application: Food & beverage, packaging, and processing lines with challenging conditions.

Get a Quick Quote for a ABB 1SBL131001R8610

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL131001R8610? Enquire Now

FAQs

This ABB contactor is designed for DIN-rail mounting using TH35-15 or TH35-7.5 rails, providing a compact footprint for panel installations. For easiest wiring, use the screw terminals on both main and auxiliary circuits and leave space for potential add-on auxiliary contact blocks. If space is limited, ensure the unit is aligned for proper coil access and ventilation to maintain performance.
The AFC09-30-10-86 offers AC-1 current up to 25 A and AC-3 current up to 9 A at voltages up to 690 V. Insulation voltage is rated at 690 V, with rated control coil voltages of 400–415 V at 50 Hz or 415–440 V at 60 Hz, making it suitable for a range of motor control and general-purpose load switching.
Yes, it is rated for 690 V mains in the main circuit. The control coil is designed for 50 Hz operation at 400–415 V and 60 Hz operation at 415–440 V, allowing compatibility with regional power systems without extensive rewiring. Built-in auxiliary contact helps with control logic and interlocking in diverse installations.
The device carries IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1 certifications, with CE and UKCA markings. Additional declarations cover ROHS, REACH, and related safety standards. These markings support compliance across Europe, North America, and other regions, simplifying cross-border procurement and installation.
Low coil power consumption (0.8 W AC-1 per pole; 0.1 W AC-3 per pole) reduces heat and energy use in control cabinets. Fast operate times, reliable switching, and compatibility with add-on accessories minimize downtime and spare parts. DIN-rail mounting and screw terminals streamline installation, enabling quicker maintenance and faster throughput in automated lines.