ABB 1SBL136205R2300 Block Contactor - 4P 690V AF Technology
Part Number: 1SBL136205R2300
Quick Summary
ABB 1SBL136205R2300 Block Contactor is a four-pole motor controller used in compact industrial drive panels. In networks with voltage fluctuations, traditional contactors may trip or misoperate; this AF technology supports a wide control voltage range of 100–250 V (AC and DC), reducing panel energy waste and improving operation in unstable networks. The device is designed to IEC/EN 60947-1 and 60947-4-1, UL 508 and CSA-compliant, with CE/UKCA declarations and IP20 protection on coil and main terminals. This combination delivers reliable performance, easier stocking, and reduced energy consumption. Compatible with DIN-rail TH35 mounting and add-on auxiliary blocks, it also supports quick installation and lower total cost of ownership.
Product Information
Extended Description
1SBL136205R2300 ABB: The AF09Z-40-00K-23 is a 4 pole - 690 V IEC or 600 UL contactor with Push-in Spring terminals, controlling motors up to 4 kW / 400 V AC (AC-3) and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Operating instructions - Contactors AFC..K, contactor relays NFC..K and accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
92.3 mm
Product Net Weight
0.285 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 25 A | (690 V) 60 °C 25 A | (690 V) 70 °C 22 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 9 A | (440 V) 60 °C 9 A | (500 V) 60 °C 9.5 A | (690 V) 60 °C 7 A | (380 / 400 V) 60 °C 9 A | (220 / 230 / 240 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe)
(400 V) 4 kW | (415 V) 4 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 4 kW | (220 / 230 / 240 V) 2.2 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.14 W | at Rated Operating Conditions AC-3 per Pole 0.15 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.5 ... 4 mm² | Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² | Flexible 1/2x 0.5 ... 4 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 4 ... 6 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.5 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm² | Flexible 1/2x 0.5 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type
Push-in Spring Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 25 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-10 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relaysAF(S)09/12/16(Z)(B) Contactors and NF(Z)(B) Contactors Relays (FR)
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CCC Certificate
CCC Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France | CCC Declaration of Conformity, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.3 kg
Package Level 1 EAN
3471523018471
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Wide control voltage range and surge protection enable reliable operation in fluctuating power systems, reducing nuisance trips and panel energy waste while simplifying inventory for 100–250 V control circuits. Business impact: improved line uptime and lower maintenance costs in automation panels. Application: motor control in conveyors, pumps, and fans where supply stability varies. Compatibility with push-in spring terminals speeds wiring and improves clamping reliability, reducing commissioning time and resistance to conductor fatigue in high-load environments. The 4P, 690 V main circuit delivers robust AC-1 and AC-3 performance, supporting up to 25 A (AC-1) and 9 A (AC-3) with a 4 kW rating at 400 V, enabling compact yet capable motor starters in machine tools and packaging lines. Industry-standard DIN-rail mounting TH35-15 or TH35-7.5 and optional auxiliary contact blocks simplify installation, retrofit, and expansion without reengineering panels. Power loss is minimized (AC-1: 1.14 W per pole; AC-3: 0.15 W per pole), delivering energy efficiency and lower running costs in continuous-operation applications. These features collectively reduce total cost of ownership while meeting IEC/EN, UL, and CSA requirements and supporting RoHS/REACH compliance for modern factories.
Get a Quick Quote for a ABB 1SBL136205R2300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL136205R2300?
Enquire Now
FAQs
Mounting is supported on DIN rail TH35-15 or TH35-7.5, ensuring a compact footprint in control panels. Attach the unit using the recommended DIN-rail clips, then wire the main circuit and control circuit through Push-in Spring Terminals. For mechanical mounting, two M4 screws (not supplied) can be positioned diagonally to secure the device. Wire sizes for the main circuit are 1/2x 0.5 … 4 mm² flexible or rigid, while control circuit wiring ranges 0.5 … 2.5 mm². This approach simplifies installation and maintains reliable electrical connections in industrial environments.
For AC-1 operation at 690 V, the contactor delivers 25 A (40 °C), 25 A (60 °C), and 22 A (70 °C). For AC-3, ratings vary by voltage: at 415–440 V, about 9 A; at 380–400 V, around 9 A; at 690 V, 7 A (60 °C). The device can switch up to 4 kW at 400 V (AC-3) and supports a main-circuit insulation voltage of 690 V, with a maximum switching frequency of 600 cycles per hour (AC-1) and 3600 cycles per hour (mechanical).
Yes. The ABB AF technology and four-pole design make it ideal for motor control in conveyors, packaging lines, and machine tools. Its 100–250 V control range accommodates voltage variability; built-in surge protection enhances reliability in harsh environments; the 4 kW at 400 V rating underpins reliable drive control, while DIN-rail mounting and add-on auxiliary blocks support scalable, serviceable installations with low total cost of ownership.
The contactor complies with IEC/EN 60947-1 and 60947-4-1, UL 508, and CSA standards, with CE and UKCA marking. It is RoHS and REACH compliant, and WEEE categorized for B2B use. IP20 protection on coil and main terminals, plus the environmental and climatic withstand specifications, ensure reliable operation in standard industrial environments and support global deployment.
Maintenance is simplified by push-in terminals and the option to extend with auxiliary contact blocks, reducing wiring rework during upgrades. AF technology provides tolerance to control voltage fluctuations, lowering nuisance trips and energy waste. With low power loss (AC-1 1.14 W per pole; AC-3 0.15 W per pole) and durable IEC/UL CSA certification, this contactor contributes to lower operating costs and higher uptime in automated lines.