ABB 1SBL157001R1110 Contactor - AF Technology
Part Number: 1SBL157001R1110
Quick Summary
ABB 1SBL157001R1110 Contactor enables reliable motor control for three-phase equipment in automation panels. Varying control voltages in industrial networks can trigger nuisance trips and energy waste, hurting uptime. Designed for IEC AC-3 duty with UL recognition, it features AF technology, built-in surge protection, and a compact, modular footprint. The device supports add-on auxiliary blocks and straightforward maintenance, helping reduce panel space, wiring complexity, and total cost of ownership. With its tolerant control range, engineers can standardize on a single solution across lines, improving service response and energy efficiency across the plant.
Product Information
Extended Description
1SBL157001R1110 ABB: The AF12-30-10-11 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 5.5 kW / 400 V AC (AC-3) or 7-1/2 hp / 480 V UL and switching power circuits up to 28 A (AC-1) or 28 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRAPR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHNOR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CLABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CNIAB001EXPU
Storage Location
4001
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
COABB001EXPU
Storage Location
4001
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DEAPRMLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DKSER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB003EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EESER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EGAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ESATD001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Lead Time
19 day
Country of Origin
France (FR)
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FISER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FRAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GBINS001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GRABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABBRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ITIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NLABB021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NOATDRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
SGIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
TRDMD001EXPU
Storage Location
4001
Country of Origin
France (FR)
Criticality
No
Lead Time
19 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USABB251EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
From stock if available, otherwise Target delivery time is
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ZATAD021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.27 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 28 A | (690 V) 60 °C 28 A | (690 V) 70 °C 24 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 12 A | (440 V) 60 °C 12 A | (500 V) 60 °C 12.5 A | (690 V) 60 °C 9 A | (380 / 400 V) 60 °C 12 A | (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 15 A | (110 V) 1-Pole, 60 °C 15 A | (110 V) 1-Pole, 70 °C 15 A | (110 V) 2 Poles in Series, 40 °C 27 A | (110 V) 2 Poles in Series, 60 °C 27 A | (110 V) 2 Poles in Series, 70 °C 24 A | (110 V) 3 Poles in Series, 40 °C 27 A | (110 V) 3 Poles in Series, 60 °C 27 A | (110 V) 3 Poles in Series, 70 °C 24 A | (220 V) 2 Poles in Series, 40 °C 15 A | (220 V) 2 Poles in Series, 60 °C 15 A | (220 V) 2 Poles in Series, 70 °C 15 A | (220 V) 3 Poles in Series, 40 °C 27 A | (220 V) 3 Poles in Series, 60 °C 27 A | (220 V) 3 Poles in Series, 70 °C 24 A | (72 V) 1-Pole, 40 °C 27 A | (72 V) 1-Pole, 60 °C 27 A | (72 V) 1-Pole, 70 °C 24 A | (72 V) 2 Poles in Series, 40 °C 27 A | (72 V) 2 Poles in Series, 60 °C 27 A | (72 V) 2 Poles in Series, 70 °C 24 A | (72 V) 3 Poles in Series, 40 °C 27 A | (72 V) 3 Poles in Series, 60 °C 27 A | (72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 7 A | (110 V) 1-Pole, 60 °C 7 A | (110 V) 1-Pole, 70 °C 7 A | (110 V) 2 Poles in Series, 40 °C 27 A | (110 V) 2 Poles in Series, 60 °C 27 A | (110 V) 2 Poles in Series, 70 °C 24 A | (110 V) 3 Poles in Series, 40 °C 27 A | (110 V) 3 Poles in Series, 60 °C 27 A | (110 V) 3 Poles in Series, 70 °C 24 A | (220 V) 2 Poles in Series, 40 °C 7 A | (220 V) 2 Poles in Series, 60 °C 7 A | (220 V) 2 Poles in Series, 70 °C 7 A | (220 V) 3 Poles in Series, 40 °C 27 A | (220 V) 3 Poles in Series, 60 °C 27 A | (220 V) 3 Poles in Series, 70 °C 24 A | (72 V) 1-Pole, 40 °C 27 A | (72 V) 1-Pole, 60 °C 27 A | (72 V) 1-Pole, 70 °C 24 A | (72 V) 2 Poles in Series, 40 °C 27 A | (72 V) 2 Poles in Series, 60 °C 27 A | (72 V) 2 Poles in Series, 70 °C 24 A | (72 V) 3 Poles in Series, 40 °C 27 A | (72 V) 3 Poles in Series, 60 °C 27 A | (72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 4 A | (110 V) 1-Pole, 60 °C 4 A | (110 V) 1-Pole, 70 °C 4 A | (110 V) 2 Poles in Series, 40 °C 15 A | (110 V) 2 Poles in Series, 60 °C 15 A | (110 V) 2 Poles in Series, 70 °C 15 A | (110 V) 3 Poles in Series, 40 °C 27 A | (110 V) 3 Poles in Series, 60 °C 27 A | (110 V) 3 Poles in Series, 70 °C 24 A | (220 V) 2 Poles in Series, 40 °C 4 A | (220 V) 2 Poles in Series, 60 °C 4 A | (220 V) 2 Poles in Series, 70 °C 4 A | (220 V) 3 Poles in Series, 40 °C 12 A | (220 V) 3 Poles in Series, 60 °C 12 A | (220 V) 3 Poles in Series, 70 °C 12 A | (72 V) 1-Pole, 40 °C 12 A | (72 V) 1-Pole, 60 °C 12 A | (72 V) 1-Pole, 70 °C 12 A | (72 V) 2 Poles in Series, 40 °C 27 A | (72 V) 2 Poles in Series, 60 °C 27 A | (72 V) 2 Poles in Series, 70 °C 24 A | (72 V) 3 Poles in Series, 40 °C 27 A | (72 V) 3 Poles in Series, 60 °C 27 A | (72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(400 V) 5.5 kW | (415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (Pe)
(415 V) 5.5 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-2 / AC-4) 300 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
NEMA Size
0
Continuous Current Rating NEMA
18 A
Horsepower Rating NEMA
(115 V AC) Single Phase 1 Hp | (200 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 2 Hp | (230 V AC) Three Phase 3 Hp | (460 V AC) Three Phase 5 Hp | (575 V AC) Three Phase 5 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 28 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7-1/2 hp | (550 ... 600 V AC) Three Phase 10 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 13 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 16 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
f65e669b-20d8-43fb-8274-7e2dbb1081c7 China (CN)
Simplified SCIP
f90543cd-ab33-4a07-b542-20643207fdf9 Poland (PL) | 57112f6f-c541-4141-b3aa-a3476f817b11 Denmark (DK) | 5ba3fae0-d77c-45e4-a594-b14912751437 Germany (DE) | ee5dc123-428b-42c2-bf95-bcc7bf7a6f19 Croatia (HR) | 95079d6e-4b3c-43c8-a92f-dc8f45fdd350 Czech Republic (CZ) | cada30f6-6e8b-417a-a1fb-79d5576f7acc Germany (DE) | 610853f9-f761-494d-8feb-c92762c10144 Poland (PL) | e4cf4642-5ba3-4776-a7c2-c73ada20453d Belgium (BE) | b6441cab-5123-4844-83ad-99a6ced43f93 Poland (PL) | 1d064804-a9ea-49be-b30a-146f8e33f26d Netherlands (NL) | cc7b3f63-6318-429b-bc3a-6e26f3d248e8 Norway (NO) | 0828aee1-deb6-4361-ad97-15189e90404b Hungary (HU) | 5d4abeaa-3e53-48d7-abb2-3239364bd15e Hungary (HU) | 62cfc0d3-8eeb-460b-b46b-a117c0a469f2 Estonia (EE) | 9aec28df-03d8-4bce-9c6a-c6903713f483 Finland (FI) | cc82e6c4-5fc9-44ca-b384-289f57c3949e Belgium (BE) | 9f9596ac-8e6b-4a02-92e0-756818a29633 Bulgaria (BG) | b279d261-5230-4000-bd99-4069e60ac3a1 Spain (ES) | f92b3ef9-5a52-498a-8223-436671bd4fff Greece (GR) | 19b08695-5e7e-4f53-b59d-fe666302cbad Portugal (PT) | 2aefec57-e310-4d93-a713-f440eacd4fc5 Germany (DE) | 9858b6d9-3d83-48fe-93fb-5966608c0d68 France (FR) | ca8f66a9-1353-4d76-9323-c7ab5d89d81d Germany (DE) | cb589a00-e5bf-4ac0-a0be-3f5f327c3f78 Germany (DE) | 8e7e3b66-fd47-4540-9a40-54f2c6df496d Sweden (SE) | 65be4510-7dab-4bee-8358-f3b3e11f3611 Sweden (SE) | 9fd4dbb7-e2d9-4358-84eb-01bb635d51a4 France (FR)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relaysAF(S)09/12/16(Z)(B) Contactors and NF(Z)(B) Contactors Relays (FR) | Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relays
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CCC Certificate
CCC Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CQC Certificate
CQC Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors | CQC Certificate, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France | CCC Declaration of Conformity, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
KC Certificate
KC Certificate AF12, AF16 3-pole contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF(S)09...AF(S)96 contactors, NF contactor relays and accessories with screw,spring and push-in terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
UL Listing Card
E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.27 kg
Package Level 1 EAN
3471523110311
Package Level 2 Units
box 27 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
7.29 kg
Package Level 3 Units
1296 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3705802
E-Number (Sweden)
3211341
AF technology with a wide control voltage range (24-60 VAC 50/60 Hz and 20-60 VDC) and built-in surge protection reduces nuisance trips and voltage-related downtime in automation panels. This translates to improved process stability and energy efficiency in conveyors, pumps, and machines that experience supply fluctuations. The 3-pole design supports IEC 690 V and UL 600 V environments, delivering up to 5.5 kW at 400 V AC (AC-3) and 28 A (AC-1), enabling higher motor capacity with fewer devices and simplified wiring. A built-in auxiliary contact streamlines control circuits, cutting panel complexity and maintenance costs. Screw terminals and block-type design simplify wiring, while compatibility with add-on auxiliary blocks and accessories enables scalable control logic without full component replacement. The modular approach minimizes downtime during upgrades and supports future expansions in modular automation architectures.
Get a Quick Quote for a ABB 1SBL157001R1110
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL157001R1110?
Enquire Now
FAQs
This 3-pole unit uses screw terminals suitable for panel wiring. It is rated for IEC 690 V and UL 600 V, with control voltage options of 24–60 V AC (50/60 Hz) or 20–60 V DC. Ensure correct torque on terminals, provide appropriate clearances, and consider add-on auxiliary blocks for future expansion.
The contactor handles motor loads up to 5.5 kW at 400 V AC (AC-3) and 28 A (AC-1). It features a 3-pole arrangement and built-in surge protection. Control is via 24–60 V AC or 20–60 V DC, with UL recognition and IEC compatibility to simplify integration into standard automation panels.
Yes. The AF technology design supports add-on auxiliary contact blocks and a modular accessories system. This allows you to tailor interlocking, signaling, and control logic without replacing the main contactor. The block-type footprint also simplifies wiring and future upgrades in compact automation cabinets.
This device is designed for IEC and UL environments, with built-in surge protection and AF technology to withstand voltage variation. Ensure compliance with local electrical codes, industrial safety standards (including AC-3 duty considerations), and install appropriate auxiliary blocks for interlocking and signaling to maintain safe startup and stop sequences.
The wide control voltage tolerance reduces panel energy waste and trips, while the compact, modular design lowers panel footprint and installation time. Built-in surge protection and scalable accessories improve reliability and reduce spare parts needs, delivering lower total cost of ownership and faster maintenance in automation applications.