ABB AFC16-04-00-34 Block Contactor - 690V IEC/UL

Part Number: 1SBL171101R3400
Manufacturer
ABB
Part number
1SBL171101R3400

Quick Summary

ABB AFC16-04-00-34 is a 4-pole block contactor for AC power control in industrial machinery. It helps engineers avoid downtime with reliable coil performance across 50 Hz and 60 Hz control circuits. Key certifications include IEC/EN 60947-1 and 60947-4-1 with UL 60947-1/4-1, plus CE and UKCA marks to support global deployments. Flexible mounting on TH35-15 or TH35-7.5 DIN rails, screw terminals, and compatibility with add-on auxiliary contact blocks simplify installation and future expansion. In business terms, this delivers predictable performance, easier spare-part planning, and a lower total cost of ownership across global panels.

Product Information

Extended Description

1SBL171101R3400 ABB: The AFC16-04-00-34 is a 4-pole (4 N.C) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 30 A (IEC AC-1) or 30 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 175 V AC 50 Hz / 208 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.298 kg
Number of Main Contacts NO
0
Number of Main Contacts NC
4
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 30 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A | (690 V) 60 °C 30 A | (690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 5.2 A | (440 V) 60 °C 5.7 A | (500 V) 60 °C 5.7 A | (690 V) 60 °C 5.1 A | (380 / 400 V) 60 °C 5.2 A | (220 / 230 / 240 V) 60 °C 4.9 A
Rated Operational Power AC-3 (Pe)
(415 V) 2.2 kW | (440 V) 3 kW | (500 V) 3 kW | (690 V) 4 kW | (380 / 400 V) 2.2 kW | (220 / 230 / 240 V) 1.1 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV | Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 175 V | 60 Hz 208 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B1 20 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AFC09, AFC12, AFC16 3 or 4-pole contactors
CQC Certificate
CQC Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.328 kg
Package Level 1 EAN
3471523021327
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Four NC main contacts in a four-pole design enables reliable, high-current power switching with minimal wiring complexity. Business Impact: Reduces installation time and potential fault points, boosting machine uptime in manufacturing lines. Application: Suitable for motor control and power distribution in conveyors and presses. Feature: Coil voltage options of 50 Hz at 175 V and 60 Hz at 208 V align with common control circuits, improving compatibility and reducing the need for transformers. Business Impact: Streamlined control wiring and lower control-system footprint. Application: Industrial automation panels with mixed voltage controls. Feature: Main circuit rated at 690 V with up to 30 A (IEC AC-1) and up to 26 A at higher ambient temperatures (70 °C) for AC-3. Business Impact: Higher uninterrupted load switching and broader electrical life in demanding environments. Application: Power switching for single-motor and light-load drives. Feature: DIN-rail mounting options TH35-15 and TH35-7.5 plus screw-terminal connections. Business Impact: Fast, repeatable installation with easy field wiring and reliable terminations. Application: Panel builders and retrofit projects. Feature: Modular AF platform with add-on auxiliary contact blocks and wide accessory support. Business Impact: Scales from basic switching to complex control schemes without replacing cores. Application: Customizable control logic and expansion in evolving automation systems. Feature: Compact footprint—45 mm width, 77 mm depth, 86 mm height, weight 0.298 kg. Business Impact: Saves panel space and reduces enclosure size, contributing to smaller overall system cost. Application: Enclosed control cabinets and compact machine panels.

Get a Quick Quote for a ABB 1SBL171101R3400

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL171101R3400? Enquire Now

FAQs

The device supports TH35-15 and TH35-7.5 DIN rails. Use 2 x M4 screws for mounting and connect the main circuit with rigid 1/2 x 1 to 6 mm² or ferrule-wired conductors per the Connecting Capacity specs. Tighten main terminals to 1.5 N·m and control terminals to 1.2 N·m. This yields secure mechanical mounting and reliable electrical connections in control panels.
The coil is rated for 50 Hz at 175 V and 60 Hz at 208 V. This aligns with standard control circuits in industrial automation, allowing direct interfacing with common control voltages without additional transformers. Coil consumption is 8 V·A hold, with pull-in values of 70 V·A (50 Hz) and 66 V·A (60 Hz).
Yes. It is rated for AC-1 up to 30 A at 690 V (open contactors suitable for general use) and provides AC-3 ratings appropriate for motor switching across voltages up to 690 V. This makes it suitable for motor starters and starter-controlled power distributions in manufacturing environments.
The AFC16-04-00-34 complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1/60947-4-1, CAN/CSA equivalents, and carries CE and UKCA declarations. These certifications support safe, compliant integration in European, North American, and other international panel builds.
With a modular AF platform, add-on auxiliary contacts, and a compact DIN-rail footprint, installation time decreases and maintenance is simplified. Reliable 690 V switching and robust coil performance reduce downtime and spare-parts inventory, delivering lower total cost of ownership over the device’s service life.