ABB 1SBL171101R8600 Block Contactor - IEC/UL 60947-4-1 690V
Part Number: 1SBL171101R8600
Quick Summary
ABB 1SBL171101R8600 block contactor enables reliable motor control in industrial power circuits. Users struggle with coil wear and downtime from miscoordinated control voltages across 50/60 Hz systems. This device adheres to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1, with CE, UL, and CSA certifications for global deployments. With DIN-rail mounting, screw terminals, and an AF platform that supports add-on accessories, it streamlines installation, reduces wiring time, and lowers total cost of ownership.
Product Information
Extended Description
1SBL171101R8600 ABB: The AFC16-04-00-86 is a 4-pole (4 N.C) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 30 A (IEC AC-1) or 30 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 415 ... 440 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.298 kg
Number of Main Contacts NO
0
Number of Main Contacts NC
4
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 30 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A | (690 V) 60 °C 30 A | (690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 5.2 A | (440 V) 60 °C 5.7 A | (500 V) 60 °C 5.7 A | (690 V) 60 °C 5.1 A | (380 / 400 V) 60 °C 5.2 A | (220 / 230 / 240 V) 60 °C 4.9 A
Rated Operational Power AC-3 (Pe)
(415 V) 2.2 kW | (440 V) 3 kW | (500 V) 3 kW | (690 V) 4 kW | (380 / 400 V) 2.2 kW | (220 / 230 / 240 V) 1.1 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV | Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B1 20 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AFC09, AFC12, AFC16 3 or 4-pole contactors
CQC Certificate
CQC Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.321 kg
Package Level 1 EAN
3471523021358
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature 1: Four-pole NC configuration provides robust power control and simplifies wiring for 3-phase motor circuits. Business impact: safer isolation and streamlined panel design; Application: conveyors, pumps, and machine tools requiring reliable AC-1 switching up to 30 A at high voltage. Feature 2: DIN rail mounting options TH35-15 or TH35-7.5 and standard Screw Terminals enable quick installation and clean, vibration-resistant wiring. Business impact: reduced panel assembly time and maintenance downtime; Application: factory automation panels with tight space constraints. Feature 3: High mains voltage rating of 690 V and coil options for 50 Hz and 60 Hz control circuits ensure compatibility with global power systems. Business impact: broadened market reach and fewer part mismatches; Application: international machinery and control cabinets. Feature 4: Low coil power loss—1.2 W per pole (AC-1) and 0.35 W per pole (AC-3)—combined with compact dimensions (45 mm x 77 mm x 86 mm) and IP20 protection. Business impact: lower operating costs, improved thermal performance, and longer service life; Application: high-cycle motor control in compact enclosures. Feature 5: AF platform compatibility with add-on auxiliary blocks and accessories supports scalable control, upgrades, and retrofit projects. Business impact: future-proofing and cost-efficient expansion; Application: modular control architectures in OEM equipment.
Get a Quick Quote for a ABB 1SBL171101R8600
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL171101R8600?
Enquire Now
FAQs
This ABB contactor supports TH35-15 or TH35-7.5 DIN rails and uses Screw Terminals for main and control circuits. Its 45 mm width, 77 mm depth, and 86 mm height align with standard enclosure layouts, while the 0.298 kg weight helps manage panel balance. The combination simplifies wiring, reduces panel space, and enables reliable, vibration-resistant installations in harsh industrial environments.
For AC-1 operation at 690 V, the Rated Operational Current is 30 A (at 40 °C, with reductions at higher temperatures). For AC-3, the rated current ranges around 5.2–5.7 A depending on voltage and conditions. This makes the device suitable for motor starting and general-purpose switching while meeting IEC/UL standards for safe, controlled transitions.
The device meets IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1, with additional CE and CSA recognitions. These certifications enable deployment across Europe, North America, and international markets, reducing qualification time for machinery and enhancing supplier conformity in multi-region projects.
Yes. The AFC/AF platform supports add-on auxiliary contact blocks and a wide range of accessories. This enables scalable control, wiring simplification, and retrofit capability to adapt to evolving control logic without replacing the base device, delivering long-term cost efficiency in OEM and maintenance projects.
Mounting via DIN rail TH35-15 or TH35-7.5, with Screw Terminals for both main and control circuits. Tightening torque is 1.2 N·m for control circuits and 1.5 N·m for main circuits. Wire with ferrules per 0.75–6 mm² and maintain 10 mm stripping length to ensure secure, vibration-resistant connections in demanding environments.