ABB 1SBL171234T8000 Block Contactor - UL/CSA 600V

Part Number: 1SBL171234T8000
Manufacturer
ABB
Part number
1SBL171234T8000

Quick Summary

ABB 1SBL171234T8000 Block Contactor is a 4-pole device that switches power circuits in motor drives. Engineers often struggle with space constraints, thermal load, and maintenance in control panels; a compact, reliable option minimizes wiring complexity and reduces downtime. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508 and CSA 22.2 No. 14, plus CE conformity, supporting global installation. For AC control applications, this 4-pole block contactor streamlines power control in panels, enabling scalable configurations and dependable operation across diverse industries. Designed for 690 V main circuit operation and 50/60 Hz coil control, it aligns with ongoing automation upgrades.

Product Information

Extended Description

1SBL171234T8000 ABB: The AFC16-40-00-80HT is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 30 A (IEC AC-1) or 30 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 220 ... 230 V AC 50 Hz / 230 ... 240 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories. H versions are specific for "Household appliances" application according to IEC 60335-1 section 30 regarding heat and fire withstand.
Minimum Order Quantity
10 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.298 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA 22.2 No. 14
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A | (690 V) 60 °C 30 A | (690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 18 A | (440 V) 60 °C 18 A | (500 V) 60 °C 15 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 18 A | (220 / 230 / 240 V) 60 °C 18 A
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 0 cycles per hour | (AC-2 / AC-4) 0 cycles per hour | (AC-3) 0 cycles per hour | (DC-13) 0 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 60 °C | Close to Contactor without Thermal O/L Relay (Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AFC09, AFC12, AFC16 3 or 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 10 piece
Package Level 1 Width
461 mm
Package Level 1 Depth / Length
161 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
3 kg
Package Level 1 EAN
3471525000306
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Four-pole main contacts (NO) provide simultaneous switching of all poles, improving reliability and reducing arcing risk in high-load circuits, which translates to longer equipment life and less downtime in conveyor, pump, and fan drives. Application: motor control in manufacturing lines where consistent start/stop cycles are critical and space is at a premium. Feature: Coil voltage compatible with 50 Hz and 60 Hz systems (220–230 V / 230–240 V) ensures seamless integration with regional control architectures. Impact: simplifies procurement and reduces custom wiring; Application: machine control panels across global facilities. Feature: Screw terminals and flexible connection options (Ferrule and rigid conductor) enable secure, vibration-resistant wiring; Impact: faster, trouble-free field wiring and lower maintenance costs; Application: installation in compact control cabinets. Feature: Compact dimensions (45 mm wide, 77 mm deep, 86 mm high) and weight (0.298 kg) save panel space; Impact: enables higher packing density and easier service access; Application: scalable panel designs in automation cells. Feature: IP20 protection at coil terminals and robust mechanical design; Impact: reliable operation in standard plant environments; Application: factory automation and material handling. Feature: Wide standards coverage (IEC/EN 60947-1, 60947-4-1, UL 508, CSA 22.2 No. 14) reduces compliance risk; Impact: accelerates global deployment; Application: international projects with mixed regulatory requirements. Feature: Compatibility with add-on auxiliary contact blocks and accessory ecosystem; Impact: future-proofing and easier expansion; Application: scalable control systems that evolve with production needs.

Get a Quick Quote for a ABB 1SBL171234T8000

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL171234T8000? Enquire Now

FAQs

Install with the recommended screw terminals using either flexible ferrule or rigid conductors per the Connecting Capacity specification. Torque for main circuit terminals is 1.5 N·m and 1.2 N·m for control terminals; ensure wire sizes fall within 0.75–6 mm² for main, 0.75–2.5 mm² for auxiliary, and 0.75–2.5 mm² for control circuits. Mounting should follow standard DIN rail or panel guidelines, leaving adequate space for heat dissipation.
Main circuit rated voltage is 690 V. Rated Operational Current AC-1 is 30 A up to 70 °C, and AC-3 is 18 A for several voltage configurations (including 380/400 V and 690 V). Rated Power AC-3 reaches 9 kW at higher voltages and 4 kW at 220–240 V. These specs suit general-purpose motor loads and other AC control tasks within IEC/UL guidelines.
Yes, it supports common AC motor control scenarios, including AC-1 and AC-3 switching with 4P configuration. It features 4 NO main contacts, screw terminal connections, and compatibility with add-on auxiliary blocks for expanded control, making it suitable for pumps, fans, and conveyor drives in industrial environments.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 508, CSA 22.2 No. 14, and CE conformity, ensuring broad regulatory acceptance for global installation and safe operation in multiple markets.
Product net width is 45 mm, depth 77 mm, height 86 mm, and weight 0.298 kg. It provides flexible main circuit connections (1/2x ferrule 0.75–6 mm², or rigid 1/2x 1–6 mm²) and auxiliary circuit connections (0.75–2.5 mm²). Terminal type is screw terminals, with IP20 protection on coil terminals.