ABB 1SBL177501R1200 Block Contactor - IEC/UL 60947

Part Number: 1SBL177501R1200
Manufacturer
ABB
Part number
1SBL177501R1200

Quick Summary

Block Contactor enables reliable motor control for industrial machinery using the ABB AF16-22-00-12 model. Wavering control voltages and panel energy waste can cause nuisance trips and downtime, impacting productivity. This AF technology contactor meets IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, and CSA/CAN qualifications, delivering broad regulatory coverage for global install bases. With a wide coil range and built-in surge protection, it reduces energy losses while supporting easy expansion with auxiliary blocks and accessories. For engineers and procurement teams, the result is consistent performance, reduced field failures, and scalable protection across multiple lines in manufacturing, packaging, and process environments.

Product Information

Extended Description

1SBL177501R1200 ABB: The AF16-22-00-12 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.27 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A | (690 V) 60 °C 30 A | (690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 18 A | (440 V) 60 °C 18 A | (500 V) 60 °C 15 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 18 A | (220 / 230 / 240 V) 60 °C 18 A
Rated Operational Power AC-3 (Pe)
(400 V) 7.5 kW | (415 V) 9 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
b82ba4d1-f9fa-48c7-9e29-deb0592589c7 China (CN)
Simplified SCIP
5dbab33b-aa8a-4202-93c0-ecea6ab15479 Poland (PL) | f9070700-d950-4c69-8a0f-ebcdf825fa2f Finland (FI) | 9db93279-6517-49d7-9c20-b23dc020d873 Czech Republic (CZ) | b9afb410-c93c-41a7-81da-05f08ac517ac Poland (PL) | b2b42fb0-0047-4b6b-9f2e-b3e641fe7401 Norway (NO) | 76483c7e-a7dc-416f-87cc-53017445d066 Germany (DE) | 193d2244-8be8-4944-ba0a-bf7c19d2532a Croatia (HR) | f18501fc-0e8b-4fbf-bac8-fba0c71fac7b Belgium (BE) | 35bfce46-0b3e-450a-bb67-c7fc7ab6cc1a Denmark (DK) | 054982b5-960e-4b27-9536-59326a985d9e Germany (DE) | cd04a8f2-94db-4c16-b321-043cfd7d2929 Germany (DE) | 24fed1f3-5480-441f-8dec-0bc1a3f28e9b Netherlands (NL) | e823b907-91e1-436c-b6e1-70961c00a12c Estonia (EE) | c2851b3b-7021-423e-b50a-c29531e09ed5 Greece (GR) | 81dd3642-3446-42b1-8940-cedc023294fb Hungary (HU) | b3188f56-0553-4b99-b920-a00f29c1c186 Spain (ES) | a978b00a-0a08-4a79-b7e0-13dcf2095a41 France (FR) | e047558c-d3d0-4546-b54f-ec1353a9b797 Poland (PL) | 277a670f-6acf-4aad-a062-60b25ca05c01 Germany (DE) | 0c67ae62-97b9-42fe-84c1-2ade7545a953 Portugal (PT) | f676f883-29a9-4b3b-99a7-2f996eea6ee0 Bulgaria (BG) | 136940d9-0fc1-4cb2-8b08-03249fd06ea3 Sweden (SE) | c7bc6563-0af3-40dd-8ccd-e0f064035883 France (FR) | 070a43dc-ddf2-4c85-9d9b-45272db23f31 Sweden (SE) | a4421e1d-176a-47c0-812a-88ef1a752568 Germany (DE) | eb7c59d0-667e-4bae-a532-bff511fe92a8 Hungary (HU) | 127d8697-c938-442c-9fbb-c0bda0e2d5ab Belgium (BE)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relaysAF(S)09/12/16(Z)(B) Contactors and NF(Z)(B) Contactors Relays (FR) | Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relays
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CCC Certificate
CCC Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CQC Certificate
CQC Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors | CQC Certificate, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France | CCC Declaration of Conformity, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
KC Certificate
KC Certificate AF16 4pole contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF09...AF96 contactors, NF contactor relays and accessories, screw and spring terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US Certificate of Compliance AF(C)09..(K) ... AF(C)38 4-pole contactors with screw and push-in spring terminals | UL-CA Certificate of Compliance AF(C)09..(K) ... AF(C)38 4-pole contactors with screw and push-in spring terminals
UL Listing Card
UL_E319322
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.27 kg
Package Level 1 EAN
3471523116320
Package Level 2 Units
box 27 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
14.58 kg
Package Level 3 Units
1296 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706350
E-Number (Sweden)
3211401
Feature → Business Impact → Application: The AF16-22-00-12 uses a four-pole design rated for a 690 V main circuit, enabling motor control up to 7.5 kW at 400 V AC (AC-3) and 30 A (AC-1) per pole. This delivers reliable high-voltage switching with compact footprint, supporting space-constrained motor control panels in conveyors, pumps, and fans. Application-wise, it minimizes downtime through robust switchgear that tolerates transient loads and provides predictable operation in harsh environments. Feature → Material and mounting → Benefit: Screw terminals and DIN rail mounting TH35-15 or TH35-7.5 streamline installation and maintenance, reducing labor time and improving cable integrity in control cabinets. Application: Industrial automation racks, machine tools, and packaging lines. Feature → Control versatility → Benefit: The coil accepts 48–130 V across 50/60 Hz and DC operation, accommodating fluctuating control supplies and unstable networks. Application: Remote or variable-power plants where control voltage stability is a concern. Feature → Protection and compliance → Benefit: Built-in surge protection and wide standards support (IEC/EN 60947-1, 60947-4-1; UL/CSA) minimize external components, simplify compliance, and ease vendor audits. Application: Industrial machines requiring certified safety and efficient energy management. Feature → Extendability → Benefit: The AF family supports add-on auxiliary contact blocks and an extensive accessory range, enabling scalable control logic and maintenance-friendly diagnostics. Application: Systems that evolve with production lines and require modular expandability. Feature → Efficiency and reliability → Benefit: Low power loss per pole (1.2 W AC-1, 0.35 W AC-3) and rapid operate times reduce energy waste and improve conveyor or pump response times. Application: High-cycle packaging, material handling, and process control where precision timing matters.

Get a Quick Quote for a ABB 1SBL177501R1200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL177501R1200? Enquire Now

FAQs

Mount the 4P contactor on a TH35 DIN rail (TH35-15 or TH35-7.5) and secure with the appropriate mounting method. Use two M4 screws for panel mounting if screws are supplied and connect the main circuit wires to the screw terminals with a stripping length of 10 mm. Ensure coil connections are made to 48–130 V control supply and tighten torque to 1.2 N·m for the control circuit and 1.5 N·m for the main circuit.
Main circuit rated operational current (AC-1) is 30 A at 690 V, with variations up to 60 °C. For AC-3, Ie is 18 A at 440–690 V depending on voltage and temperature. Rated operating power (AC-3) is up to 9 kW at common voltages (e.g., 400–690 V). These values guide motor sizing and switching energy in your applications.
Yes. The AF16 family carries IEC/EN 60947-1 and 60947-4-1 standards, UL 60335-2-40 LZGH2 A2L, UL 60947-1 and UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, and related CE/UKCA declarations, ensuring global compliance for electrical equipment in consumer and industrial settings.
Ideal for motor control in conveyors, pumps, fans, and machine tools where space is at a premium. Its four-pole design, wide coil voltage range, and surge protection suit dynamic industrial environments. Compatibility with add-on auxiliary blocks helps tailor control circuits and diagnostics for complex automation schemes.
The block contactor uses screw terminals for robust connections and supports DIN-rail mounting for easy replacement. With a compact 0.27 kg net weight and rated switching capabilities (AC-1/AC-3), it’s designed for high-cycle operation. Plan for periodic torque checks (1.2 N·m control, 1.5 N·m main) and inspection of auxiliary blocks to maintain diagnostic capability and reliability.