ABB AF16-22-00-13 Block Contactor - IEC 60947-4-1
Part Number: 1SBL177501R1300
Quick Summary
Block Contactor ABB AF16-22-00-13 is a robust motor switch for industrial automation and panel integration. It tolerates wide control voltages from 100 to 250 V (AC or DC), helping maintain reliable start-up and reducing energy waste when incoming supplies vary. The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, CSA, and CE/UKCA marks, ensuring safety and regulatory alignment. With DIN-rail mounting, screw-terminals, and easy extension via auxiliary contact blocks, it supports scalable control in modern machines while lowering total cost of ownership. Its built-in surge protection and compact footprint further enhance panel density and reliability in demanding manufacturing environments.
Product Information
Extended Description
1SBL177501R1300 ABB: The AF16-22-00-13 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Country of Origin
Switzerland (CH)
Lead Time
70 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHABB001EXPU
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.27 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A | (690 V) 60 °C 30 A | (690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 18 A | (440 V) 60 °C 18 A | (500 V) 60 °C 15 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 18 A | (220 / 230 / 240 V) 60 °C 18 A
Rated Operational Power AC-3 (Pe)
(400 V) 7.5 kW | (415 V) 9 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
9d8a072b-a8f5-4676-b483-01d7b0790faf China (CN)
Simplified SCIP
b78cfaf1-eadb-4bb4-97dc-2a1cdf017461 Hungary (HU) | d03ecc2e-d359-4279-a453-0b53c3f346f3 Estonia (EE) | 4c4da815-9e57-4338-b4c2-c7dd6d469ae4 Bulgaria (BG) | 12215a01-d5d4-487d-aefc-49a631950c59 Finland (FI) | 87c60133-0842-409b-8367-9b128052e0c3 Croatia (HR) | f604823e-18bf-4922-8d45-09f7ae770cf3 Czech Republic (CZ) | 5dfe0032-f993-48b1-8ef0-af08f8bea918 Belgium (BE) | f9d37d51-2e64-4d5a-a152-fe4919c49331 France (FR) | d1b305d9-6f2a-4e41-ade5-46c6357ac787 Sweden (SE) | 1b6a6cb1-5656-446b-a4c9-f09ef3b838ca Germany (DE) | f9fd8f69-6fc5-4874-aba0-ae59a8eecbbb France (FR) | 50cef61b-b111-48ff-8211-fde63d5ff29e Portugal (PT) | 54da4f40-0f88-4def-a444-ff7927ba1f07 Germany (DE) | f4cc6c46-9b79-4964-a25a-b54e14ade8a6 Denmark (DK) | 95de85cc-dc9e-4048-8fc5-484fa27e66c1 Sweden (SE) | 0b1aada1-a86d-4aa8-a299-216c2b16c542 Germany (DE) | 82206802-2db8-4129-9320-194156a7e7aa Germany (DE) | 31b71a14-e935-43b5-a7fb-b4025b2bd8f9 Poland (PL) | 5d487ee1-780e-4c73-9d1e-cd9046b9d83c Greece (GR) | 0be059b6-8df7-49d2-aa16-b7a2201a1640 Poland (PL) | bba2756c-ccd3-4d1d-b838-e797a4a7c48d Germany (DE) | 4a077ff3-f7a0-413b-918b-e31b6c07b1e0 Poland (PL) | 4e4b8581-eb7f-41c4-a428-e52606345475 Netherlands (NL) | 59401d2b-63eb-484c-a62a-1c06a8b5d0ad Norway (NO) | ca90f5a0-0ce5-4b0d-9678-e9fb8858a272 Hungary (HU) | 62e546af-91bc-4db0-a50b-785fd57b2bb6 Belgium (BE) | 62faea84-9cb9-46e6-be9a-92e0980d1148 Spain (ES)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relaysAF(S)09/12/16(Z)(B) Contactors and NF(Z)(B) Contactors Relays (FR) | Environmental Product Declaration - AF09/12/16(Z)(B) Contactors and NF(Z) Contactor relays
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
CB Certificate
CB Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CCC Certificate
CCC Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
CQC Certificate
CQC Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors | CQC Certificate, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France | CCC Declaration of Conformity, Contactor, AF09,AF12,AF16, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
KC Certificate
KC Certificate AF16 4pole contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF09...AF96 contactors, NF contactor relays and accessories, screw and spring terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US Certificate of Compliance AF(C)09..(K) ... AF(C)38 4-pole contactors with screw and push-in spring terminals | UL-CA Certificate of Compliance AF(C)09..(K) ... AF(C)38 4-pole contactors with screw and push-in spring terminals
UL Listing Card
UL_E319322
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.27 kg
Package Level 1 EAN
3471523116337
Package Level 2 Units
box 27 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
14.58 kg
Package Level 3 Units
1296 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706351
E-Number (Sweden)
3211402
Wide control voltage range (100-250 V AC/DC) enables stable relay operation across network fluctuations, reducing false tripping and energy waste. This translates to lower energy costs and less downtime in automation panels that experience voltage drift, such as conveyors and processing lines. The result is improved machine uptime and predictable start-up sequences in variable-installation sites. Integrated surge protection adds a layer of safety, limiting transients that could affect coil life and contact wear, while the compact block design saves panel space and simplifies wire routing in tight enclosures. Application in motor starter assemblies is streamlined by the ability to add auxiliary contact blocks, expanding monitoring and interlock capability without replacing the base device. The 4P configuration delivers balanced main contacts (NO/NC) for reliable motor control with minimal wiring complexity, supporting easier diagnostics and faster commissioning. Compatibility with TH35 DIN rails (TH35-15 and TH35-7.5) and the screw-terminal connections makes installation straightforward for technicians, reducing commissioning time and human error. Power loss is minimized per pole, delivering energy-efficient operation across AC-1 and AC-3 duty, which translates to measurable energy savings in high-cycle machines. Overall, AF16-22-00-13 supports compliance, long-term reliability, and a lower total cost of ownership for industrial panels and control cabinets.
Get a Quick Quote for a ABB 1SBL177501R1300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL177501R1300?
Enquire Now
FAQs
Install on a TH35 DIN rail (TH35-15 or TH35-7.5) or mount with screws as required. Wire the main circuit with flexible ferrule 0.75–6 mm² and control circuit with 0.75–2.5 mm², using 10 mm wire stripping. Tighten main terminals to 1.5 N·m and control terminals to 1.2 N·m. Ensure coil voltage is within 100–250 V and observe polarity for DC operation.
For AC-3 duty at 690 V, the rated operational current Ie is 10.5 A, with a corresponding Pe of about 4–9 kW depending on voltage. The device also provides 30 A AC-1 capability at 690 V, supporting motor control and general-load switching in mixed-duty panels while maintaining safe thermal limits.
Yes. The AF16-22-00-13 is designed for AC-3 duty and provides reliable starting for motors with higher inertia. It offers 18 A at 415–440 V AC-3 and up to 7.5 kW (AC-3) at 400 V, making it suitable for conveyors, pumps, and similar machinery in manufacturing lines while maintaining compact panel footprints.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, UL 60947-1, UL 60947-4-1, CSA C22.2, and carries CE and UKCA markings. It also aligns with RoHS and REACH declarations, ensuring regulatory compliance across global markets and smoother integration into certified control systems.
Low power loss per pole (AC-1 1.2 W, AC-3 0.35 W) reduces heat and energy consumption in frequent-switching applications. Built-in surge protection minimizes coil stress, extending life, while DIN-rail compatibility and modular auxiliary contact blocks simplify upgrades and fault monitoring. These features translate to lower maintenance costs and improved uptime in production environments.