ABB 1SBL211001R8801 Block Contactor - IEC 60947-4-1
Part Number: 1SBL211001R8801
Quick Summary
ABB 1SBL211001R8801 Block Contactor is designed to switch motor loads in 3-pole AC power circuits. Engineers often contend with wiring complexity and slow spare parts replacement when expanding control schemes; this device reduces setup time by offering a compact, reliable block design and a single NC auxiliary contact for simple interlocks. With IEC/EN 60947-1 and 60947-4-1 compliance, UL 60947-4-1, CSA references, and CE declarations, it supports global deployments while meeting safety and performance requirements. This combination delivers predictable performance in industrial automation, improving control circuit reliability and helping you manage lifecycle costs across deployments.
Product Information
Extended Description
1SBL211001R8801 ABB: The AFC25-30-01-88 is a 3-pole - 690 V IEC or 600 V UL contactor with 1 N.C built-in auxiliary contact and Screw terminals, mainly controlling power circuits up to 11 kW / 400 V AC (AC-3) or 15 hp / 480 V AC UL and 32 A (AC-1) or 30 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 240 ... 260 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.303 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 32 A | (690 V) 60 °C 32 A | (690 V) 70 °C 28 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 25 A | (380 / 400 V) 60 °C 25 A | (220 / 230 / 240 V) 60 °C 25 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 25 A | (380 / 400 V) 60 °C 25 A | (220 / 230 / 240 V) 60 °C 25 A
Rated Operational Current AC-15 (Ie)
(24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 5.5 kW
Rated Operational Power AC-3e (Pe)
(415 V) 11 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.4 W | at Rated Operating Conditions AC-3 per Pole 0.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Connecting Capacity Main Circuit
Rigid Solid 1/2x 1 ... 4 mm² | Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 1.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWG | Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 13 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 60 °C | Close to Contactor without Thermal O/L Relay (Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AFC09 ... AFC38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AFC09 ... AFC38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AFC09, AFC12, AFC16 3 or 4-pole contactors
CCC Certificate
CCC Certificate, Contactor, AFC25
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-Certificate of Compliance AFC09 ... AFC38 3-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.324 kg
Package Level 1 EAN
3471523021532
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3-pole, 690 V rated coil with 50 Hz or 60 Hz control voltages (230–240 V / 240–260 V). Business Impact: Enables universal motor control across regions and voltage profiles, reducing parts variety and stocking needs. Application: Suited for AC motor control in conveyors, pumps, fans, and general purpose drive loads. Feature: Block design with a built-in 1 NC auxiliary contact and extensible add-on contact blocks. Business Impact: Easy expansion for interlocks and control logic without replacing the base device, lowering maintenance costs and downtime. Application: Scalable control circuits in evolving automation lines. Feature: Screw terminals for main, auxiliary, and control circuits. Business Impact: Fast, secure terminations and repeatable torque—minimizing commissioning time and wiring faults. Application: Industrial panel assemblies with tight installation schedules. Feature: Compact footprint (45 mm width, 77 mm depth, 86 mm height) and weight around 0.303 kg. Business Impact: Space-efficient installation in crowded control cabinets, enabling denser layouts and easier service access. Application: OEM and retrofit projects with limited panel real estate. Feature: Compliance with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA standards and IP20 protection. Business Impact: Global acceptability and safer operation across applications, reducing compliance risk and qualification time. Application: International manufacturing facilities and cross-border deployments. Feature: Rated Operational Currents and power ratings (AC-1, AC-3, AC-3e) and short-time withstand characteristics. Business Impact: Predictable performance for motor starting and running, helping optimize energy use and reduce electrical wear. Application: 3-phase motor control in industrial automation environments.
Get a Quick Quote for a ABB 1SBL211001R8801
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL211001R8801?
Enquire Now
FAQs
Begin by aligning the device in the panel, connect main circuit wires to the 1/2x 16-10 AWG terminals, and secure auxiliary and control circuit connections within the specified 10 mm stripping length. Tighten all terminals to 1.5 N·m for main, 1.2 N·m for auxiliary and control, and verify IP20 protection coverage. Ensure coil voltage matches the control supply: 230–240 V at 50 Hz or 240–260 V at 60 Hz, and confirm safe clearance around the device before powering up.
For AC-1 operation at 690 V, the device provides about 32 A, with ratings maintained at 60 °C and 70 °C. For AC-3 operation, typical ratings are 25 A at 415 V (and similarly at 380/400 V) with 60 °C ambient temperature. These values reflect the contactor’s suitability for motor starting and running under common industrial loads.
Yes. The coil control voltage is 50 Hz 230–240 V or 60 Hz 240–260 V, making it compatible with standard 230 V control networks. This supports straightforward integration into typical plant control architectures while maintaining reliable coil pull-in and release characteristics.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, and CSA C22.2 standards, along with CE declarations. These certifications reflect safety, reliability, and cross-border compatibility for global installations in industrial environments.
The 1SBL211001R8801 utilizes a block contactor design with a 45 mm width and supports add-on auxiliary contact blocks, enabling scalable interlocking and control configurations. CAD drawings (2D/3D) are available, and the compact dimensions plus screw-terminal terminations simplify integration into AF platform-based control panels and associated accessories.