ABB AFC26-40-00-51 Block Contactor - 690V IEC/UL 4P

Part Number: 1SBL231201R5100
Manufacturer
ABB
Part number
1SBL231201R5100

Quick Summary

Block Contactor AFC26-40-00-51 from ABB provides reliable 4-pole control for motor power circuits in industrial automation. Engineers frequently struggle with matching coil voltages to local mains and ensuring fault-safe operation under varying thermal conditions. This device complies with IEC/EN 60947-4-1 and UL 60947-4-1, plus CE and UKCA declarations, enabling safe, compliant integration across global installations. With DIN rail mounting, screw-terminal wiring, and modular add-on accessories, it supports scalable control architectures while reducing downtime. The combination of robust insulation, precise timing, and compact footprint translates to longer service life and lower total cost of ownership for panel builders and maintenance teams.

Product Information

Extended Description

1SBL231201R5100 ABB: The AFC26-40-00-51 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 45 A (IEC AC-1) or 45 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.393 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 45 A | (690 V) 60 °C 40 A | (690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW | (415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.6 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 16 mm² | Rigid 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 45 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.411 kg
Package Level 1 EAN
3471523024083
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AFC26-40-00-51 uses a 4-pole, NO main contact arrangement, reducing panel wiring complexity and improving reliability in motor control circuits. This translates to fewer parts to stock and faster commissioning in conveyor lines, pumps, and fans. Feature → Business Impact → Application: Coil voltage options of 400-415 V at 50 Hz and 480 V at 60 Hz ensure cross‑regional compatibility, simplifying global installations and reducing the need for multiple coil variants. Application: suitable for 50/60 Hz AC control systems in manufacturing plants that require consistent magnetic switching without sacrificing timing performance. Feature → Business Impact → Application: Rated operational current AC-1 up to 45 A at 690 V and AC-3 up to 23.2 A at common voltages provide safe motor starting for medium-sized loads, improving startup reliability for drives and compressors. Application: motor starters in machine tools, material handling, and process equipment. Feature → Business Impact → Application: Low coil power loss (1.6 W per pole in AC-1; 0.42 W per pole in AC-3) reduces energy consumption and minimizes heat in control panels, supporting compact enclosure designs. Application: energy-efficient control cabinets and reduced cooling requirements. Feature → Business Impact → Application: Screw terminals and flexible conductor ranges (1.5 to 16 mm²) enable quick, secure wiring and easier field retrofits. Application: panel upgrades and retrofit projects with diverse conductor types. Feature → Business Impact → Application: DIN rail mounting (TH35-15 or TH35-7.5) and accessible mounting hardware speed installation and service, reducing field labor and downtime in factory automation environments. Application: panel assembly, switchgear, and line-side protection. Feature → Business Impact → Application: Compliance and certifications (IEC/UL/CSA CE/UKCA) ensure regulatory alignment across regions, enabling faster time-to-market and safer integration in certified systems. Application: critical for automotive, food & beverage, and other regulated industries. Feature → Business Impact → Application: IP20 protection and a wide ambient temperature range (-40 to +70 °C near the cont actuator; storage -60 to +80 °C) allow operation in harsh factory environments, minimizing failures due to dust, vibration, or thermal stress. Application: outdoor or dusty production lines with robust enclosure requirements. Feature → Business Impact → Application: Comprehensive electrical and mechanical data (Icw, Ui, f, torque) provide designers with precise selection criteria, reducing overdesign and ensuring reliable protection of downstream equipment. Application: system design and protection coordination in power distribution panels.

Get a Quick Quote for a ABB 1SBL231201R5100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL231201R5100? Enquire Now

FAQs

The coil control circuit voltage is 400–415 V at 50 Hz or 480 V at 60 Hz, allowing compatibility with European and North American mains configurations.
Yes. It is designed for mounting on TH35-15 or TH35-7.5 DIN rails, with optional securing screws (2 x M4) for solid installation.
AC-1 rated current is up to 45 A at 690 V (deratings apply with higher ambient temperatures). AC-3 ratings vary by voltage, up to 23.2 A at 220–240 V and as low as 10.5 A at 690 V.
Standards include IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, CAN/CSA, with CE, UKCA, CB, BV, DNV, and RINA declarations for global product compliance.
IP20 protection on terminals, ambient temperature range from -40 to +70 °C near the cont actor, and a 4P configuration with screw terminals support reliable operation in dusty or vibrating factory floors; use DIN-rail mounting and correct torque specs for secure connections.