ABB 1SBL231201R8600 Block Contactor - IEC/UL 690 V

Part Number: 1SBL231201R8600
Manufacturer
ABB
Part number
1SBL231201R8600

Quick Summary

Block Contactor 1SBL231201R8600 is a robust ABB device for motor control in industrial automation. Engineers often struggle with coil voltage compatibility and wiring reliability, but this unit supports 400–415 V at 50 Hz and 415–440 V at 60 Hz with screw terminals for secure, field-wirable connections. It carries essential approvals including CE, UKCA, and UL/CSA listings, with CB and BV certificates enabling global deployment. The design can be extended with add-on auxiliary contact blocks and supports both DIN rail mounting and standard screw mounting, reducing panel space and installation time. In service, it delivers 4 NO main contacts, 690 V insulation, and a 45 A AC-1 rating for reliable motor control with compact footprint.

Product Information

Extended Description

1SBL231201R8600 ABB: The AFC26-40-00-86 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 45 A (IEC AC-1) or 45 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 415 ... 440 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.393 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 45 A | (690 V) 60 °C 40 A | (690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW | (415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV | Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 0 cycles per hour | (AC-2 / AC-4) 0 cycles per hour | (AC-3) 0 cycles per hour | (DC-13) 0 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.6 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 16 mm² | Rigid 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 45 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
CQC Certificate
CQC Certificate, Contactor, AF*26, AF*30, AF*38, Made in France
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.411 kg
Package Level 1 EAN
3471523014879
Package Level 3 Units
864 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Four-pole design with four normally open main contacts and 690 V insulation. Business Impact: Enables efficient switching of three-phase motors up to 45 A (AC-1), reducing wiring complexity and space in control panels. Application: Suitable for conveyors, pumps, and machine tools in manufacturing environments. Feature: Dual coil voltage range 400–415 V (50 Hz) / 415–440 V (60 Hz). Business Impact: Seamless regional compatibility and simplified stock management, lowering miswiring risk. Application: Global installations across diverse power systems. Feature: DIN-rail and screw-mount compatibility (TH35-15 or TH35-7.5; screws supplied separately). Business Impact: Faster installation, easier retrofits, and scalable panel design. Application: New builds and upgrades in automation lines. Feature: Screw terminals and flexible conductor ranges for Main and Control circuits. Business Impact: Secure wiring with reliable torque and long-term maintenance reductions. Application: Control cabinets with mixed conductor sizes. Feature: Low power loss and fast operate times (AC-1 1.6 W per pole; 9–26 ms energize; 4–18 ms release). Business Impact: Lower heat generation, improved energy efficiency, and quicker motor start/stop sequences. Application: High-cycle applications like fans and pumps. Feature: Broad certifications (IEC/EN 60947-1, 60947-4-1; UL 60947-1, 60947-4-1; CE/UKCA; CB; BV; DNV; RINA; CQC; CCC). Business Impact: Simplified global compliance and risk reduction for international projects. Application: Marine, energy, and process industries requiring multi-regulatory approval. Feature: Operational range and environmental resilience (IP20, -25 to 60/70 °C depending on relay, up to 3000 m). Business Impact: Reliable operation in harsh factory floors with minimal derating. Application: Outdoor or harsh indoor installations where temperature and altitude vary. Feature: Expandability with auxiliary contact blocks. Business Impact: Customizable control logic without replacing main contactor, lowering total cost of ownership. Application: Complex machine control with interlocks and signaling.

Get a Quick Quote for a ABB 1SBL231201R8600

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL231201R8600? Enquire Now

FAQs

Yes. The device supports both TH35-15 and TH35-7.5 DIN rail mounting and can also be installed using two M4 screws for a secure, flexible panel fit. This versatility helps streamline retrofits and new installations in compact control panels.
The 1SBL231201R8600 features 4 main NO contacts (NO) and 0 NC/minor auxiliary contacts in the base configuration. It can be extended with add-on auxiliary contact blocks to tailor signaling and interlock functions to specific machine control requirements.
For AC-1 operation at 690 V, the rated operational current is 45 A (at 40 °C, 60 °C 40 A, 70 °C 32 A). For AC-3 operation at various voltages (e.g., 415 V 60 °C 21.2 A, 440 V 60 °C 20 A, 690 V 60 °C 10.5 A), the device provides reduced current ratings to reflect switching and motor starting loads.
It complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, and is listed for CAN/CSA. It also carries CE and UKCA marks, with CB, BV, DNV, RINA, CQC, CCC certificates available for broader regulatory coverage.
Expect low power loss (1.6 W per pole in AC-1), short operate times, and IP20 protection at terminals. Routine checks should verify screw torque (Main 2.5 N·m, Control 1.2 N·m) and inspect wiring integrity. The design supports auxiliary block upgrades, reducing total cost of ownership during equipment upgrades.