ABB 1SBL231501R4200 Block Contactor - IEC 60947-4-1

Part Number: 1SBL231501R4200
Manufacturer
ABB
Part number
1SBL231501R4200

Quick Summary

The ABB 1SBL231501R4200 Block Contactor is a 4-pole AC switch for motor and equipment control. Users often wrestle with coil voltage compatibility and wiring density in control panels; this model offers clearly defined coil options and robust screw terminals to simplify integration. It carries essential certifications, including IEC/EN 60947-1 and 60947-4-1, UL 60947-1, and UL 60947-4-1, plus RoHS and REACH compliance with IP20 protection for reliable global operation. For procurement teams, the DIN-rail mounting compatibility, extendable block design, and compatibility with the AF platform translate into lower installation risk, faster commissioning, and long-term reliability across diverse industrial environments.

Product Information

Extended Description

1SBL231501R4200 ABB: The AFC26-22-00-42 is a 4-pole (2 N.O + 2 N.C) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 45 A (IEC AC-1) or 45 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 277 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.393 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 45 A | (690 V) 60 °C 40 A | (690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 277 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.6 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 16 mm² | Rigid 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 45 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.413 kg
Package Level 1 EAN
3471523023109
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature 4-pole construction with 2 normally open and 2 normally closed contacts enables precise control of three-phase loads, reducing wiring complexity and improving safety. Business Impact ensures robust motor and equipment control with a compact footprint, supporting tighter panel layouts and easier serviceability. Application suitable for HVAC, conveyors, and general machinery where clean, measurable switching is required. Feature Coil voltage options of 230–240 V at 50/60 Hz and 277 V at 60 Hz provide global compatibility, reducing inventory and engineering effort. Business Impact simplifies worldwide deployments and standardizes control logic across regions. Application ideal for global manufacturing lines and international equipment. Feature Screw terminals and wide wiring capacity improve reliability, ease termination, and minimize connection failures. Application supports flexible conductor types from ferrules to solid wires, streamlining installation. Feature DIN rail mounting (TH35-15 or TH35-7.5) enables fast, secure mounting in modern control panels. Business Impact cuts installation time and reduces panel footprint. Application supports quick retrofits and future expansions with add-on auxiliary contact blocks. Feature Compliance with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, and RoHS/REACH reduces regulatory risk and accelerates approvals. Application suitable for certified environments and multi-region projects. Feature IP20 protection and screw terminals provide dependable operation in typical panel environments, with straightforward maintenance. Business Impact lowers maintenance costs and extends service life. Application appropriate for general purpose machinery where reliability matters.

Get a Quick Quote for a ABB 1SBL231501R4200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL231501R4200? Enquire Now

FAQs

Install the unit on a compatible TH35 DIN rail (TH35-15 or TH35-7.5) in the control panel. Mount securely, then terminate the main circuit conductors in the screw terminals using 1/2x 1.5…16 mm² or 2x 1.5…16 mm² ferrules as specified. Tighten main circuit terminals to 2.5 N·m and control circuit terminals to 11 in·lb for reliable operation.
For AC-1 at 690 V, the rated operational current is 45 A (40 °C) and 40 A (60 °C). For AC-3, ratings vary with voltage and temperature (e.g., 22 A at 380/400 V to 23.2 A at 220/230/240 V in specified conditions). These values support soft-start and motor control with robust short-time withstand ratings up to 300 A.
The coil is rated for 230–240 V at 50 Hz and 277 V at 60 Hz. This dual-frequency capability enables global deployment without custom coil variants, simplifying procurement and reducing stocking complexity for multinational projects.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, CAN/CSA equivalents, CE, UKCA, BV, DNV, and RINA declarations. It is RoHS and REACH compliant, with an IP20 protection rating, supporting safe operation in standard industrial environments.
The 1SBL231501R4200 uses durable screw terminals and a modular design with add-on auxiliary blocks, reducing replacement frequency and service time. The compact DIN-rail form factor, coupled with reliable 690 V insulation and UL/CE/CSA certifications, lowers panel space, minimizes wiring errors, and contributes to lower total cost of ownership.