ABB 1SBL231501R8500 Block Contactor - IEC/EN 60947-4-1

Part Number: 1SBL231501R8500
Manufacturer
ABB
Part number
1SBL231501R8500

Quick Summary

Block Contactor 1SBL231501R8500 from ABB provides reliable AC motor control for drives and conveyors in industrial automation. End users often struggle with coil voltage compatibility, mounting choices, and serviceability in harsh environments. This device meets IEC/EN 60947-4-1 and UL 60947-1 standards and carries CE and UKCA declarations to support cross-border compliance. With a compact 4P, 2NO + 2NC design and screw terminals, it delivers straightforward wiring and dependable operation. The result is improved machine uptime, easier panel integration, and lower lifecycle costs for OEMs and maintenance teams.

Product Information

Extended Description

1SBL231501R8500 ABB: The AFC26-22-00-85 is a 4-pole (2 N.O + 2 N.C) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 45 A (IEC AC-1) or 45 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 380 ... 400 V AC 50 Hz / 400 ... 415 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.393 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 45 A | (690 V) 60 °C 40 A | (690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 380 ... 400 V | 60 Hz 400 ... 415 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.6 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 16 mm² | Rigid 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 45 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.41 kg
Package Level 1 EAN
3471523022416
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → 4-pole design with 2 normally open and 2 normally closed contacts provides clean, defined switching for multi-motor and load control, reducing miswiring risks and ensuring predictable sequencing. Business Impact → This configuration supports reliable AC-1 and AC-3 motor control at up to 45 A, improving startup performance and reducing inrush-related downtime. Application → Ideal for conveyors, pumps, and machine tools in production lines where precise control and robust contact reliability are required. Feature → Coil voltage compatibility across 380–400 V AC at 50 Hz and 400–415 V AC at 60 Hz enables global operation without separate coil variants. Business Impact → Simplifies multinational deployments and spare-part management, lowering stocking complexity. Application → Suitable for international plant rollouts and OEM equipment fleets. Feature → Screw terminals and 45 A main current rating offer solid, vibration-resistant connections with straightforward maintenance. Business Impact → Faster field wiring, reduced maintenance calls, and dependable terminal integrity in harsh environments. Application → Panel builders and field technicians benefit from easier serviceability and long-term reliability. Feature → Compact DIN rail mounting TH35-15 and optional TH35-7.5 footprint enables dense control-panels. Business Impact → Maximizes panel real estate, speeds installation, and supports modular automation architectures. Application → OEM control panels for packaging, material handling, and process automation. Feature → Ability to extend with add-on auxiliary contact blocks and a broad accessories range. Business Impact → Scales control logic without replacing the base unit, saving cost and downtime during modernization. Application → Complex control schemes in packaging and material handling lines. Feature → IP20 protection for coil and main terminals plus defined tightening torques. Business Impact → Compliance with safety standards while ensuring a reliable seal against dust and moisture at typical panel heights. Application → Industrial control cabinets and machine builds with strict enclosure requirements.

Get a Quick Quote for a ABB 1SBL231501R8500

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL231501R8500? Enquire Now

FAQs

The 1SBL231501R8500 uses a standard TH35 DIN rail mounting option and ships with a 2 x M4 screw fixing requirement if mounting on a chassis. It fits 35 x 15 mm rails and should be secured with the specified torque to prevent vibrations. For wiring, use screw terminals with flexible or rigid copper conductors within the 1/2 x 1.5 to 16 mm² range for main circuits and 0.75 to 2.5 mm² for control circuits, ensuring proper wire stripping lengths as stated in the technical data.
For AC-1 operation at 690 V, the rated operational current is 45 A at 40 °C, 40 A at 60 °C, and 32 A at 70 °C. For AC-3 operation, ratings vary with voltage: at 415 V 60 °C it is 21.2 A, at 440 V 60 °C 20 A, at 500 V 60 °C 17.6 A, and at 690 V 60 °C 10.5 A. Power and switching frequency are aligned to IEC/EN 60947-4-1 standards.
Yes. With a 4P configuration, 2 NO and 2 NC contacts, and 690 V insulation, it is designed for AC-1 and AC-3 motor control applications typical in conveyors and pump systems. Its screw-terminal connections and DIN-rail mounting simplify integration in control panels, while the add-on auxiliary blocks support more complex control logic when needed.
The device carries CE declarations and UKCA declarations for cross-border compliance, along with UL/CSA documentation for North American markets. It also has CB and BV certificates and is referenced in DoC documents for CE, UKCA, and UL. This broad certification footprint helps meet regulatory requirements in diverse industrial environments.
The unit’s modular design supports add-on auxiliary contact blocks, enabling scalable control without replacing the base contactor. Screw terminals provide durable connections, reducing wiring faults and service calls. The compact DIN-rail footprint saves panel space, accelerating installation, while compliant certifications minimize risk during audits and asset upgrades, contributing to lower total cost of ownership.