ABB 1SBL277001R1300 Contactor - AF Technology 100-250V
Part Number: 1SBL277001R1300
Quick Summary
ABB AF contactor 100-250V controls motors in industrial automation applications. Voltage fluctuations often trigger trips and energy waste; this device tolerates wide control voltages to keep systems running. Built with CE compliance and UL compatibility, it supports robust operation in harsh environments and unstable networks. The compact AF block design accepts add-on auxiliary contact blocks for scalable control logic, reducing panel space and wiring complexity. OEMs and system integrators benefit from a reliable, easy-to-expand motor-control solution that lowers total cost of ownership while improving uptime and energy efficiency.
Product Information
Extended Description
1SBL277001R1300 ABB: The AF30-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 15 kW / 400 V AC (AC-3) or 20 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
BRAPR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Country of Origin
Switzerland (CH)
Lead Time
0 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHABB001EXPU
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
CHNOR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
CLABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Alternative Product Reference
3AUA0000089006
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
CNIAB001EXPU
Storage Location
4001
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
Alternative Product Reference
3AUA0000089006
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
COABB001EXPU
Storage Location
4001
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
DEAPRMLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
DKSER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
DUABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
DUABB003EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
EESER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
EGAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
ESATD001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Alternative Product Reference
3AUA0000089006
Replacement Part ID
3AUA0000089006
Product Availability Class
Replaced
Lead Time
999 day
Country of Origin
France (FR)
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
FISER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
FRAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
GBINS001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
GRABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
INABBRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
ITIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
NLABB021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
NOATDRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
SGIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
TRDMD001EXPU
Storage Location
4001
Alternative Product Reference
3AUA0000089006
Country of Origin
France (FR)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
USABB251EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Alternative Product Reference
3AUA0000089006
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Replaced
Product Sales Status
Active
Quote Only
No
Replacement Part ID
3AUA0000089006
Stocked At Warehouses
ZATAD021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
86 mm
Product Net Height
86 mm
Product Net Weight
0.31 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 50 A | (690 V) 60 °C 42 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 32 A | (440 V) 60 °C 32 A | (500 V) 60 °C 28 A | (690 V) 60 °C 21 A | (380 / 400 V) 60 °C 32 A | (220 / 230 / 240 V) 60 °C 33 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 32 A | (440 V) 60 °C 32 A | (500 V) 60 °C 28 A | (690 V) 60 °C 21 A | (380 / 400 V) 60 °C 32 A | (220 / 230 / 240 V) 60 °C 33 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 50 A | (220 V) 3 Poles in Series, 60 °C 42 A | (220 V) 3 Poles in Series, 70 °C 37 A | (72 V) 1-Pole, 40 °C 50 A | (72 V) 1-Pole, 60 °C 42 A | (72 V) 1-Pole, 70 °C 37 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 50 A | (220 V) 3 Poles in Series, 60 °C 42 A | (220 V) 3 Poles in Series, 70 °C 37 A | (72 V) 1-Pole, 40 °C 50 A | (72 V) 1-Pole, 60 °C 42 A | (72 V) 1-Pole, 70 °C 37 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 25 A | (220 V) 3 Poles in Series, 60 °C 25 A | (220 V) 3 Poles in Series, 70 °C 25 A | (72 V) 1-Pole, 40 °C 25 A | (72 V) 1-Pole, 60 °C 25 A | (72 V) 1-Pole, 70 °C 25 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Power AC-3 (Pe)
(400 V) 15 kW | (415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Operational Power AC-3e (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.4 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid Solid 1/2x 2.5 ... 4 mm² | Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 5 hp | (440 ... 480 V AC) Three Phase 20 hp | (550 ... 600 V AC) Three Phase 25 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWG | Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 28 A | (440 ... 480 V AC) Three Phase 27 A | (550 ... 600 V AC) Three Phase 27 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
4f3b93ba-d893-43a8-86d8-5062ef221263 China (CN)
Simplified SCIP
4b38a7a7-afb5-49f5-9b33-2c624eac65ff Croatia (HR) | 001b4413-235c-4e5b-91b8-b78ca529a37a Germany (DE) | 1ac756f7-3362-4c57-a051-301d1b2631f6 Czech Republic (CZ) | 61726276-aef1-41ee-956f-7149a7a00447 Belgium (BE) | bde85b91-8637-4dad-9ac1-00557baf5eff Germany (DE) | c9edbbeb-a3d2-426c-96a7-781f43ace2f3 Sweden (SE) | 510348f1-6b44-4028-8c1f-2206037ca139 Poland (PL) | 8695d696-2b9f-470f-8d3a-057581de0acb Germany (DE) | 334b84cb-53b1-43bb-ba9e-f7cfcbb3b710 France (FR) | 66fa63a7-3673-441a-843c-caa0fb0f5a1d Sweden (SE) | 5cd77f86-e47d-43a8-ad8c-e85fdc68b149 France (FR) | 54af1b70-cc1e-4735-b3fd-7dde50bdd654 Germany (DE) | 79ddb0ae-b77a-4221-9912-601e8bfa5fd8 Poland (PL) | 63c07a57-aa48-47b4-a280-b795f508aed7 Poland (PL) | 47c1a8aa-fb04-4f48-80ba-759a11571913 Hungary (HU) | 5fcf2ca7-b20a-41dd-a90d-3cb4c6308f06 Norway (NO) | 61372fac-07bd-4693-85d9-5b5d89a10898 Netherlands (NL) | 32878405-129d-4910-9dbe-0e54cb597916 Hungary (HU) | 12193980-3887-47de-8dca-87348d7e028b Finland (FI) | df77598a-c8fe-4865-8696-3bd2315cd0d8 Estonia (EE) | 4702dcb5-573d-4e8b-bfbc-cd48224d6dc3 Spain (ES) | a2e5f4a5-2b2b-4601-8da5-03fc49503e2a Denmark (DK) | e00e4e87-6911-4cc6-b2e8-655785df8a20 Greece (GR) | 13d531d3-fa6f-475a-8b1e-fdc78158aabb Portugal (PT) | a30b0d50-98ff-41b4-8f60-ba65601e9aa4 Germany (DE) | f18982c2-b8a3-40a5-8194-e892c301de95 Bulgaria (BG) | b11b6597-3f21-4afa-b70c-2f2e08c34e15 Belgium (BE)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)26/30/38(Z)(B) Contactors (FR) | Environmental Product Declaration AF26/30/38(Z)(B) Contactors (CN)
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF26(Z)(B), AF30(Z)(B), AF(Z)(B)38 3-pole contactors, AFS26, AFS30, AFS38 safety contactors
CCC Certificate
CCC Certificate AF26, AF30, AF38, AF26(Z)B, AF30(Z)B, AF38(Z)B 3 and 4-pole contactors, AFS26, AFS30, AFS38 safety contactors
CQC Certificate
CQC Certificate, Contactor, AF*26, AF*30, AF*38, Made in France | CQC Certificate, Contactor, AF26,AF30,AF38, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France | CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
KC Certificate
KC Certificate AF26...AF38 3-pole contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF(S)09...AF(S)96 contactors, NF contactor relays and accessories with screw,spring and push-in terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
UL Listing Card
E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
87 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.31 kg
Package Level 1 EAN
3471523111233
Package Level 2 Units
box 21 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
13.95 kg
Package Level 3 Units
1080 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706285
E-Number (Sweden)
3211382
Feature wide control voltage range 100-250 V AC/50/60 Hz and DC → Business Impact reduces need for multiple controllers or transformers, enabling simpler panel designs and faster commissioning in diverse control environments; Application suitable for machines with varying control signals, such as conveyors or presses. Feature 3-pole 690 V IEC / 600 UL rating; motor power capability up to 15 kW at 400 V AC (AC-3) and 50 A (AC-1) → Business Impact supports high-load, reliable motor control with common power standards, minimizing part counts and inventory; Application for heavy-duty motor drives and general-use power circuits. Feature built-in surge protection → Business Impact protects downstream electronics and reduces external protection components, lowering total installation cost; Application ideal for networks with voltage spikes or limited panel protection. Feature AF technology block-type design for easy extension with auxiliary contact blocks → Business Impact enables scalable control logic and reduced wiring complexity; Application for interlocks and extended control schemes. Feature screw terminals → Business Impact simplifies wiring, improves connection reliability, and speeds field installation; Application advantageous in panel assembly and retrofit projects. Feature compatibility with add-on accessories and auxiliary blocks → Business Impact supports customization for safety circuits, signaling, and remote control; Application for compliant, expandable control panels. Feature compact footprint and modular design → Business Impact saves panel space, reduces enclosure size, and lowers overall equipment cost; Application suitable for OEM equipment and retrofit projects. Note: Lead times and stock status vary by region; consulting local distributors ensures accurate delivery timelines and availability.
Get a Quick Quote for a ABB 1SBL277001R1300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL277001R1300?
Enquire Now
FAQs
This 3-pole contactor is rated for 690 V IEC and 600 V UL with motor control up to 15 kW at 400 V AC (AC-3) and 50 A (AC-1). It uses screw terminals, making retrofit and panel upgrades straightforward for common 3-phase motors.
The unit accepts 100-250 V AC/50/60 Hz and DC control voltages, which accommodates wide fluctuations in control signals and minimizes tripping due to voltage variation, improving uptime in variable power conditions.
Yes, the AF30 series features built-in surge protection to safeguard circuits. It is also designed for easy expansion with add-on auxiliary contact blocks, enabling extended control logic without replacing the base device.
Screw terminals provide reliable, secure connections and faster wiring during installation. Its block-type AF technology supports modular accessory integration, reducing panel complexity and enabling scalable configurations.
The product is CE compliant and UL compatible where applicable, aligning with common regulatory requirements for industrial motor controls. Certification applicability should be confirmed for your specific region and installation.