ABB 1SBL281074R2601 Block Contactor - CE/UL Certified

Part Number: 1SBL281074R2601
Manufacturer
ABB
Part number
1SBL281074R2601

Quick Summary

ABB 1SBL281074R2601 is a block contactor for controlling three-phase motors in industrial automation. In panel installations, engineers often face coil voltage compatibility and mounting constraints that slow commissioning. The device is CE and UL certified, RoHS compliant, with 690 V insulation and IP20 coil terminals to meet demanding safety standards. It belongs to the AX32 AX40 family and offers front- or side-mount add-on auxiliary blocks for flexible control wiring, all in a compact 54 mm width. This combination reduces panel footprint, simplifies maintenance, and supports scalable motor control for OEM equipment and PLC panels. With 3 main NO contacts and 1 NC auxiliary contact, it handles typical duty cycles while delivering reliable, long-life operation in demanding environments.

Product Information

Extended Description

1SBL281074R2601 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A | (690 V) 40 °C 55 A | (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 32 A | (440 V) 55 °C 32 A | (500 V) 55 °C 28 A | (690 V) 55 °C 21 A | (380 / 400 V) 55 °C 32 A | (220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)
(690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 105 V | 60 Hz 110 ... 127 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.5 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522400260
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
The AX32 style 3-pole block design reduces panel space while maintaining robust motor control, enabling faster commissioning and easier maintenance. Feature → Business Impact → Application: 3 main normally open contacts and 1 normally closed auxiliary contact simplify wiring and diagnostics for three-phase motor circuits in packaging lines and conveyors. Result: fewer wiring errors and quicker fault isolation in high-availability systems. Feature → Coil voltage compatibility (105 V at 50 Hz or 110–127 V at 60 Hz) → ensures seamless integration with common control circuits; Application: PLC panels and starter assemblies reduce control cabinet complexity and inventory requirements. Feature → Rated operational current AC-3 up to 32 A (depending on voltage) and AC-1 up to 55 A at 220/240 V → supports a wide range of motor sizes and starting profiles with controlled inrush; Application: belt conveyors, pumps, and fans in OEM equipment. Feature → Maximum breaking capacity 820 A at 440 V and 340 A at 690 V, plus 6 kV impulse withstand → provides robust protection for switching inductive loads and short-term surges; Application: large drives and critical loads in material handling. Feature → IP20 coil terminals, tightness and torque specs (coil 1 N·m, main circuit 2.3 N·m) → ensures reliable termination and vibration resistance in industrial environments; Application: panel-mounted installations with secure wiring. Feature → RoHS, REACH, UL/CE certifications and a comprehensive approvals package → ensures compliance across global supply chains; Application: regulated manufacturing, export-ready assemblies, and customer audits. The result is a dependable, compliant solution that aligns with modern machine-building standards and lifecycle cost reduction.

Get a Quick Quote for a ABB 1SBL281074R2601

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL281074R2601? Enquire Now

FAQs

This AX32 block contactor is designed with a compact 54 mm width and supports front or side mounting auxiliary blocks, enabling flexible wiring and easy integration into standard panel layouts. Ensure space for the 90 mm depth and 108.3 mm height, and follow the torque recommendations for reliable terminal connections.
For AC-3 operation, Ie is 32 A at 415/440 V and 28–32 A at various voltages, with 21 A at 690 V. These values reflect the device’s suitability for motor starting and short-term duty in mid-sized three-phase drives, balancing switching performance and thermal limits.
Yes. With three main NO contacts, a built-in NC auxiliary contact, and a 690 V insulation rating, it is well-suited for motor control in conveyors and pumps. The device supports reliable switching at common control voltages and provides a compact footprint for panel-intensive environments.
The product carries CE and UL certifications, RoHS/REACH compliance, CCC and CQC listings, and UL/CSA general use ratings. These certifications validate safety, environmental compliance, and suitability for global manufacturing and distribution, reducing regulatory risk in audits and customer specifications.
The device delivers energy-efficient operation with 2.5 W power loss per pole in AC-1 and 0.9 W per pole in AC-3, plus high reliability and low maintenance due to solid-state-compatible design. Increases in uptime, reduced wiring complexity, and lifecycle cost reductions contribute to a favorable ROI in OEM projects and modernized control panels.