ABB 1SBL281074R3601 Block Contactor - 690 V CE/UL Certified
Part Number: 1SBL281074R3601
Quick Summary
ABB 1SBL281074R3601 is a block contactor used for controlling three-phase motors in industrial power circuits. Engineers often struggle with mounting versatility, accessory options, and thermal performance in motor control solutions. This AX32/AX40 family delivers CE conformity, UL certification, and CB/CCC declarations, reducing compliance risk across international deployments. The design emphasizes a compact footprint, integrated auxiliary NC contact, and front or side-mount accessory blocks to fit tight control panels. In automation and machine-building contexts, it supports common control voltages (190 V at 50 Hz and 220 V at 60 Hz) and 690 V rated insulation, delivering reliable switching with minimal heat and energy loss. The result is lower installation costs, quicker commissioning, and improved uptime for demanding manufacturing environments.
Product Information
Extended Description
1SBL281074R3601 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A | (690 V) 40 °C 55 A | (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 32 A | (440 V) 55 °C 32 A | (500 V) 55 °C 28 A | (690 V) 55 °C 21 A | (380 / 400 V) 55 °C 32 A | (220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V | 60 Hz 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.5 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522400369
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main normally open contacts and one normally closed auxiliary contact. Business Impact: Enables direct motor control with built-in feedback paths, reducing wiring complexity and maintenance points. Application: Ideal for 3-phase motor control in packaging lines and material-handling equipment. Feature: 690 V insulation rating and 50/60 Hz control circuit voltage compatibility. Business Impact: Supports broad international mains standards while maintaining safe, reliable operation under peak loads. Application: Suitable for high-voltage motor starters in automation cells and conveyor drives. Feature: Compact 54 mm width, 90 mm depth, and 108.3 mm height with IP20 terminal protection. Business Impact: Maximizes panel density and simplifies installation without compromising accessibility. Application: Dense control panels in small-to-medium automation cabinets. Feature: 2.5 W per pole power loss (AC-1) and 0.9 W (AC-3) per pole. Business Impact: Reduces energy waste and thermal load, extending component life and lowering cooling requirements. Application: Continuous-duty motor switching in continuous processes. Feature: Front- or side-mount add-on auxiliary blocks. Business Impact: Provides flexible modularity for retrofits and future upgrades without reworking enclosures. Application: Easy integration in existing machines and modular automation platforms. Feature: Comprehensive certifications (CE, UL, CB, CCC, CQC, RoHS/REACH). Business Impact: Accelerates regulatory approvals and supports global deployments. Application: Global machine builders and OEMs seeking compliant motor-control solutions.
Get a Quick Quote for a ABB 1SBL281074R3601
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL281074R3601?
Enquire Now
FAQs
Install the unit using screw terminals with standard 54 mm width, 90 mm depth, and 108.3 mm height. Connect three main poles for the motor feed, plus the single NC auxiliary contact for feedback or interlock. Ensure control voltage matches 190 V at 50 Hz or 220 V at 60 Hz and use front- or side-mount add-on blocks as needed.
Key ratings include three main NO contacts and one NC auxiliary contact rated for up to 690 V, with control circuit voltage 190 V at 50 Hz or 220 V at 60 Hz. Ie ratings are 55 A for AC-1 at lower voltages and 32 A at AC-3 across common industrial voltages; insulation voltage Ui is 690 V.
The data provides rated DC-13 current values, with relevant DC performance up to multiple voltages (e.g., 24 V to 500 V ranges). For your DC-13 load, verify the specific coil and contact ratings listed (such as 0.55–2 A ranges at higher DC voltages) to ensure compatibility with your circuit design.
This model aligns with CE conformity, UL certification, CB certification, CCC declarations, and additional RoHS/REACH compliance. These certifications support global deployments in regulated industries, helping OEMs meet regional electrical safety and environmental standards.
The contactor supports add-on auxiliary blocks for front or side mounting, enabling easy expansion of control logic without reworking the enclosure. This modularity reduces downtime during upgrades, simplifies wiring for interlocks and signaling, and improves long-term maintainability in evolving automation projects.