ABB 1SBL281074R8010 Block Contactor - UL Certified

Part Number: 1SBL281074R8010
Manufacturer
ABB
Part number
1SBL281074R8010

Quick Summary

ABB 1SBL281074R8010 Block Contactor enables reliable 3‑phase motor control in industrial automation applications. Engineers often face coil voltage compatibility and panel-space constraints that complicate commissioning and maintenance. This 3-pole, AC-operated contactor delivers a built-in auxiliary NO contact and supports add-on auxiliary blocks for front or side mounting, helping you tailor the circuit to precise needs. With CE conformity, UL certification, and RoHS compliance, it meets global safety and environmental requirements while minimizing regulatory risk. Its compact 54 mm width and IP20 protection simplify tight-control-panels, reducing installation time and wiring complexity. By combining robust electrical ratings with installation flexibility, it supports faster project timelines and lower total cost of ownership.

Product Information

Extended Description

1SBL281074R8010 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A | (690 V) 40 °C 55 A | (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 32 A | (440 V) 55 °C 32 A | (500 V) 55 °C 28 A | (690 V) 55 °C 21 A | (380 / 400 V) 55 °C 32 A | (220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.5 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522399809
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707341
Feature: Three main normally open contacts and one auxiliary normally open contact in a block-contactor design. Business Impact: Simplifies motor control wiring and enhances control logic visibility for maintenance teams. Application: Ideal for 3‑phase motors up to 690 V AC in compact control panels. Feature: AC-operated control circuit with 50/60 Hz compatibility and a coil voltage of 220–230 V at 50 Hz or 230–240 V at 60 Hz. Business Impact: Reduces coil voltage mismatch and enhances reliability across regional mains standards. Application: Widely suitable for European and North American installations. Feature: Add-on auxiliary contact blocks for front or side mounting. Business Impact: Expands control flexibility without replacing the base device, lowering spare parts inventory. Application: Scalable to complex control schemes in conveyors, pumps, and fans. Feature: Mechanical footprint and protection: 54 mm wide, 90 mm deep, 108.3 mm high; IP20 terminals; Screw-terminal design; Weight 0.667 kg. Business Impact: Minimizes panel depth, simplifies wiring, and improves accessibility during commissioning. Application: Ready for mounted installations in tight electrical cabinets. Feature: Electrical ratings and performance: Rated Operational Current AC-3 up to 32 A at multiple voltages; AC-1 up to 55 A; Short-time withstand and high breaking capacity. Business Impact: Supports efficient, safe motor starting with predictable thermal performance. Application: Suitable for industrial drives and machine components with frequent switching. Feature: Compliance and environmental: CE, UL, RoHS, REACH, WEEE B2B. Business Impact: Ensures global market access and reduces compliance risks. Application: Fits multinational projects and cross-border supply chains.

Get a Quick Quote for a ABB 1SBL281074R8010

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL281074R8010? Enquire Now

FAQs

The device has a compact footprint with 54 mm width, 90 mm depth, and 108.3 mm height. It uses screw-terminals for all main, auxiliary, and control connections, with a recommended tightening torque of 2.3 N·m on the main circuit and 1 N·m on auxiliary and control circuits.
The control circuit is AC-operated for 50 Hz at 220–230 V and 60 Hz at 230–240 V, accommodating standard regional mains without requiring coil transformers in most installations.
AC-3 rated current is typically 32 A at 415–440–500–690 V variants (and 21 A at 690 V for certain ratings), while AC-1 rated current is 55 A at 220–240 V and remains 32 A at many higher voltages depending on ambient temperature.
The contactor carries CE conformity, UL certification, and RoHS compliance, along with REACH, TSCA, CCC, CCC DoC, and WEEE B2B registrations, enabling global deployment and regulatory assurance.
Low coil power (2.5 W AC-1 per pole, 0.9 W AC-3 per pole) reduces heat and energy use, while built-in and add-on auxiliary contacts simplify wiring and diagnostics. The IP20 rating and modular mounting support long service life with minimal downtime, lowering maintenance and replacement costs.