ABB 1SBL281074R8401 Block Contactor - CE Certified

Part Number: 1SBL281074R8401
Manufacturer
ABB
Part number
1SBL281074R8401

Quick Summary

ABB 1SBL281074R8401 Block Contactor is a three‑pole, AC‑operated device used to switch three‑phase motors in industrial power circuits. This compact block design supports reliable motor control in tight panel spaces, reducing wiring complexity and footprint. The challenge engineers often face is delivering robust control that complies with global standards while remaining easy to install and service. This product carries CE and UL certifications, along with RoHS and REACH declarations, ensuring regulatory alignment across major markets. With CAD compatibility, front or side add‑on contact blocks, and a wide range of accessories, it delivers a scalable solution for evolving automation needs. In practice, it translates to faster wiring, safer operation, and lower total cost of ownership for panel builders and OEMs.

Product Information

Extended Description

1SBL281074R8401 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A | (690 V) 40 °C 55 A | (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 32 A | (440 V) 55 °C 32 A | (500 V) 55 °C 28 A | (690 V) 55 °C 21 A | (380 / 400 V) 55 °C 32 A | (220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.5 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522400840
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707340
Feature: Three main poles and a built-in auxiliary NC contact simplify wiring and reduce panel depth. Business Impact: Faster panel assembly, lower wiring errors, and compact footprints. Application: Ideal for 3‑phase motor control in confined spaces. Feature: AC operated control circuit with 110 V nominal (50/60 Hz) supports common control architectures. Business Impact: Seamless integration with standard control systems and reduced customization. Application: Directly compatible with typical PLC outputs and relays. Feature: Add-on auxiliary contact blocks for front or side mounting plus a broad accessory range. Business Impact: Flexible logic interlocks, signaling, and safety interdependencies without redesigns. Application: Customizable signaling and interlock schemes in machinery. Feature: Rated Operational Current AC‑3 at up to 32 A across 415–690 V, with supplementary AC‑1 performance and a 60 Hz drive. Business Impact: Higher motor starting capacity with predictable thermal behavior, reducing downtime. Application: Drives conveyors, pumps, and fans in process lines. Feature: Mechanical and electrical robustness with IP20 protection and solid torque specs; CAD drawings available for fast engineering. Business Impact: Easier installation, reliable maintenance, and streamlined documentation. Application: Suitable for panel builders, OEMs, and machine builders seeking reproducible designs. Feature: Comprehensive certifications (CE, UL, CCC/CQC, RoHS/REACH) and material compliance. Business Impact: Regulatory peace of mind and broader market access with proven conformity. Application: Global deployment across automotive, packaging, and automation sectors.

Get a Quick Quote for a ABB 1SBL281074R8401

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL281074R8401? Enquire Now

FAQs

Install the 3‑pole block contactor in the control enclosure using standard screw terminals, torqueing auxiliary, control, and main terminals to the specified values. Use the provided CAD drawings to ensure proper mounting clearance and add-on auxiliary contact blocks as needed for your control logic. Verify rated operational voltage compatibility (690 V main, 110 V control) and ensure 50/60 Hz operation matches the control circuit.
For 690 V operation at 55 °C, the Rated Operational Current AC‑3 (Ie) is 21 A. This reflects the device’s suitability for switching a three‑phase motor under typical load and starting conditions in industrial environments.
Yes, the contactor is designed for industrial use with broad temperature and altitude ranges and IP20 protection on terminals. It is specified to operate from −25 to 70 °C near the device (depending on cooling and auxiliary features) and without derating up to 3000 m altitude. Field installations in factories and machinery benefit from its robust electrical ratings and modular accessory options.
The product carries CE declarations, UL certificate, CCC/CQC certifications, and RoHS/REACH declarations. These certifications validate compliance with European, North American, and Asian safety and environmental standards, ensuring regulatory clearance for global deployments and reducing time‑to‑market concerns for OEMs.
Routinely inspect coil voltage integrity and terminal torque (Main 2.3 N·m, Auxiliary 1 N·m, Control 1 N·m). Keep spare auxiliary contacts and add‑on blocks compatible with the AX32/AX40 family, and reference the AX 06–40A instructions for coil and interlock configurations. Regular maintenance checks help prevent contact wear, overheating, and unwanted arcing, extending service life.