ABB 1SBL281074R8601 Block Contactor - UL/CE Certified

Part Number: 1SBL281074R8601
Manufacturer
ABB
Part number
1SBL281074R8601

Quick Summary

ABB 1SBL281074R8601 Block Contactor is a three-pole switch for controlling 3-phase motors up to 690 V AC. Engineers often face wiring complexity and downtime due to mismatched control components; this device simplifies integration with a built-in NC auxiliary contact and AC-operated control coil. CE, UL, and CCC certifications with RoHS compliance provide confidence for global deployments, including European and Asia-Pacific installations. The compact footprint, compatible AX32-40A accessory ecosystem, and reliable ABB engineering translate into faster panel assembly and lower lifecycle costs while maintaining robust fault tolerance.

Product Information

Extended Description

1SBL281074R8601 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A | (690 V) 40 °C 55 A | (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 32 A | (440 V) 55 °C 32 A | (500 V) 55 °C 28 A | (690 V) 55 °C 21 A | (380 / 400 V) 55 °C 32 A | (220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.5 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522400864
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3 main poles plus 1 built-in NC auxiliary contact. Business impact: simplifies motor control wiring and reduces components, lowering panel complexity and installation time. Application: suitable for three-phase motor circuits up to 690 V AC in conveyors, pumps, and HVAC drives. Feature: AC coil drive for 50 Hz and 60 Hz networks (400-415 V / 415-440 V). Business impact: broad control-system compatibility and seamless integration with standard industrial PLCs. Application: aligns with common plant electrical ecosystems and minimizes control-circuit rework. Feature: compact 54 mm width with 90 mm depth and 108.3 mm height; weight 0.667 kg. Business impact: saves cabinet space and enables denser layouts in control panels. Application: ideal for space-constrained automation cabinets. Feature: rated operational current AC-3 up to 32 A at multiple voltages; Icw up to 600 A short-time withstand. Business impact: reliable motor starting with high inrush tolerance, reducing nuisance trips in demanding loads. Application: appropriate for medium-size motors and constant-torque applications. Feature: IP20 protection on terminals and screw-terminal design; tightens to 2.3 N·m main, 1 N·m auxiliary/control. Business impact: enhances electrical safety and simplifies installation with proven torque specs. Application: preferred for new-build and retrofit projects requiring secure connections. Feature: RoHS, REACH, WEEE compliance and CE/UL/CQC declarations. Business impact: ensures regulatory alignment and smoother supplier audits. Application: ideal for global manufacturing footprints with strict compliance demands.

Get a Quick Quote for a ABB 1SBL281074R8601

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL281074R8601? Enquire Now

FAQs

The 1SBL281074R8601 is designed to fit within the AX32-40A family’s accessory ecosystem, offering a 3-pole main contact arrangement with a built-in NC auxiliary contact. It supports similar coil voltages and control circuit interfaces, enabling straightforward substitution or expansion in existing installations. When upgrading, verify coil voltage (50 Hz 400–415 V or 60 Hz 415–440 V) and ensure panel clearance meets the 54 mm width. Use the same spindle torque for main terminals (2.3 N·m) and compliant auxiliary torque (1 N·m) to maintain reliability.
For AC-3 operation at 690 V, the device provides a rated operational current of 21–32 A depending on voltage and temperature; specifically 32 A at 415–440 V in 55 °C scenarios. For AC-1, the rated current is higher at lower switching voltages, with typical values around 55 A at 220/240 V and similar figures for other low-voltage configurations. Short-time withstand (Icw) includes 400 A for 10 seconds and 65 A for 15 minutes, ensuring short-term fault endurance during motor starting.
Yes, the device supports 690 V main circuit operation with a rated insulation voltage of 690 V and 6 kV impulse withstand on the auxiliary circuit, providing protection against surges in industrial settings. It also features IP20 protection on terminals, and ROHS/REACH compliance, which helps with regulatory requirements in many sectors. Its mechanical switching frequency and robust thermal performance further ensure reliable operation in moderate to challenging environments.
The product carries CE for European conformity, UL certification for North American safety compliance, and CCC certification for China, along with CQC and CCC DoC documentation. These certifications simplify supplier qualification, reduce third-party testing needs, and support audits across global manufacturing sites. RoHS and WEEE declarations also aid in environmental compliance, making this contactor suitable for multi-region deployments with stringent regulatory expectations.
The 1SBL281074R8601 offers a compact footprint, integrated auxiliary contact, and low per-pole power loss (2.5 W AC-1, 0.9 W AC-3), which collectively reduce energy waste and heat in the control circuit. Its long mechanical life (up to 3600 cycles per hour) and rated fault tolerance minimize downtime and maintenance costs. Compatibility with standard ABB accessories enables scalable automation, supporting faster upgrades and a lower total cost of ownership in modern control panels.