ABB 1SBL281074R8810 Block Contactor - 690V CE

Part Number: 1SBL281074R8810
Manufacturer
ABB
Part number
1SBL281074R8810

Quick Summary

Block Contactor ABB 1SBL281074R8810 controls 3-phase motors in medium-power drives up to 690 V AC. For panel builders and OEMs, tight spaces and complex wiring can slow commissioning and increase error risk. The AX32/AX40 family offers built-in auxiliary contact, AC-operated control, and a range of accessories to simplify installation. Compliance with CE declarations, UL/CSA recognition, and RoHS guarantees support for global automation projects. With compact dimensions, IP20 protection, and a total package of robustness and ease-of-use, it delivers reliable control while reducing downtime and lifecycle cost.

Product Information

Extended Description

1SBL281074R8810 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A | (690 V) 40 °C 55 A | (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 32 A | (440 V) 55 °C 32 A | (500 V) 55 °C 28 A | (690 V) 55 °C 21 A | (380 / 400 V) 55 °C 32 A | (220 / 230 / 240 V) 55 °C 32 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW | (440 V) 18.5 kW | (500 V) 18.5 kW | (690 V) 18.5 kW | (380 / 400 V) 15 kW | (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.5 W | at Rated Operating Conditions AC-3 per Pole 0.9 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522399885
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3 main NO contacts and 1 NO auxiliary contact provide reliable motor control. Benefit: Streamlined wiring and compact footprint reduce panel size and installation time, enabling easier enclosure layout for conveyor lines and machine tools. Application: Suitable for 3-phase motor start/stop in packaging and processing lines. Feature: Coil voltage 230-240 V at 50 Hz or 240-260 V at 60 Hz ensures compatibility with standard control circuits. Benefit: Simplifies control-signal sourcing and minimizes miscircuit adapters, lowering wiring errors. Application: Direct integration with standard mains-powered control networks. Feature: 54 mm width, 90 mm depth, 108.3 mm height and 0.667 kg weight. Benefit: Easy fit in modern switchgear racks and tight panels, reducing enclosure remodelling costs. Application: Renovation projects and OEM installations where space is at a premium. Feature: IP20 protection and screw terminals. Benefit: Safer operation and durable field connections with straightforward maintenance. Application: Indoor, dry environments and maintenance-friendly applications. Feature: Rated currents Ie AC-1 and AC-3 across voltages (55 A AC-1 at 220/240 V; 32 A AC-3 at 415–690 V). Benefit: Clear motor sizing guidance reduces over- or under-specification, improving energy efficiency and protection. Application: Medium-power motors up to ~18 kW depending on voltage. Feature: Add-on auxiliary contact blocks for front or side mounting. Benefit: Flexible control architectures and future expansion without changing base devices. Application: Control circuits needing expanded signaling in evolving automation tasks.

Get a Quick Quote for a ABB 1SBL281074R8810

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL281074R8810? Enquire Now

FAQs

To install the 1SBL281074R8810, verify coil voltage matches your control supply (230-240 V at 50 Hz or 240-260 V at 60 Hz) and connect the 3 main NO contacts plus the 1 NO auxiliary contact. Use screw terminals for secure wiring and ensure IP20-rated enclosure protection. Mounting should follow manufacturer guidelines to maintain thermal performance.
At 690 V operation, the contactor supports up to 55 A in AC-1 service and 32 A in AC-3 service, depending on ambient temperature and coil voltage. It is designed for 690 V insulation, with protective class IP20 and a rated short-time withstand and switching frequency suitable for moderate-duty motor control.
Yes. With 3 NO main contacts and 1 NO auxiliary contact, and an AC-3 rating of up to 32 A at higher voltages, the device is well suited for starting and stopping three-phase motors in packaging lines. The compact form factor simplifies control cabinet design and helps reduce wiring complexity.
The AX32/AX40 family includes CE conformity with declarations of conformity, UL/CSA certification for relevant models, and RoHS compliance. Additional certifications such as CCC, CQC, and RoHS updates ensure robust worldwide acceptance and regulatory alignment for complex supply chains.
The device fits within a compact footprint: 54 mm net width, 90 mm net depth, and 108.3 mm net height, with a product net weight of 0.667 kg. These dimensions simplify enclosure planning, enable denser panel layouts, and reduce overall equipment footprint in modern switchgear.