ABB 1SBL291001R5100 Contactor - 690V IEC/UL

Part Number: 1SBL291001R5100
Manufacturer
ABB
Part number
1SBL291001R5100

Quick Summary

AFC contactor 1SBL291001R5100 provides reliable AC motor control for industrial equipment. For panel builders, coil voltage compatibility and wiring complexity can slow commissioning and raise installation risk. This 3-pole device complies with IEC/EN 60947-4-1 and UL 60947-4-1, plus CE and UKCA certifications, with IP20 protection on terminations. By offering DIN-rail mounting and easy add-on auxiliary blocks, it delivers scalable control with dependable switching performance, reducing downtime and lifecycle costs. In short, it blends robust global compliance with practical integration advantages for modern automation projects.

Product Information

Extended Description

1SBL291001R5100 ABB: The AFC38-30-00-51 is a 3-pole - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 18.5 kW / 400 V AC (AC-3) or 25 hp / 480 V AC UL and 50 A (AC-1) or 50 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
86 mm
Product Net Height
86 mm
Product Net Weight
0.351 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 50 A | (690 V) 60 °C 42 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-6b (Pe)
(400 / 415 V) 40 °C, 50 / 60 Hz 24 kvar | (400 / 415 V) 70 °C, 50 / 60 Hz 20 kvar | (400 / 415 V) 55 °C, 50 / 60 Hz 24 kvar | (500 / 550 V), 40 °C, 50 / 60 Hz 33 kvar | (500 / 550 V) 55 °C, 50 / 60 Hz 33 kvar | (500 / 550 V) 70 °C, 50 / 60 Hz 23 kvar | (690 V) 40 °C, 50 / 60 Hz 43 kvar | (690 V) 55 °C, 50 / 60 Hz 43 kvar | (690 V) 70 °C, 50 / 60 Hz 32 kvar
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.4 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid 1/2x 2.5 ... 10 mm² | Rigid 1/2 x 2.5 ... 10 mm²
Connecting Capacity Auxiliary Circuit
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 28 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AFC09 ... AFC38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AFC09 ... AFC38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AFC26, AFC30, AFC38 3-pole contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-Certificate of Compliance AFC09 ... AFC38 3-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
87 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.372 kg
Package Level 1 EAN
3471523024199
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AFC contactor is a 3-pole block contactor rated for a main circuit up to 690 V, enabling motor control for pumps, conveyors, and fans with high reliability and reduced device count. This translates to lower panel complexity and lower total cost of ownership in industrial automation. Application: suitable for AC-3 and AC-1 control in 400–415 V and 480–690 V networks, including 18.5 kW (AC-3) at 415 V and 24 A at higher voltages, helping engineers size drives and switchgear accurately. Feature → Business Impact → Application: Coil voltage is 400–415 V at 50 Hz and 480 V at 60 Hz, simplifying integration with standard control systems while reducing wiring errors. Application: ideal for OEMs upgrading control panels to common European and North American voltage standards. Feature → Business Impact → Application: DIN rail mounting TH35-15 or TH35-7.5 plus 2 x M4 screw mounting enables fast, secure installation in control cabinets. Application: supports compact layouts and easy maintenance. Feature → Business Impact → Application: Flexible main and auxiliary connections (screw terminals, ferrules) allow versatile wiring with 1/2x 1.5–10 mm² and 1/2x 2.5–10 mm² options. Application: simplifies harnesses and reduces termination time. Feature → Business Impact → Application: Coils show low power loss (2.4 W per pole AC-1; 1.3 W per pole AC-3), delivering energy efficiency and cooler operation in continuous-duty applications. Application: beneficial in energy-conscious machines and battery-backed systems. Feature → Business Impact → Application: Wide environmental and safety certifications (IEC/EN 60947-1, 60947-4-1; UL; CSA; CE/UKCA) paired with IP20 protection, ensuring global compliance and safer installations. Application: suitable for multinational manufacturing sites with diverse regulatory requirements. Feature → Business Impact → Application: Capable of auxiliary add-on blocks and accessories, enabling scalable control topology as machine logic evolves. Application: supports future-proof panel designs and easier expansion.

Get a Quick Quote for a ABB 1SBL291001R5100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL291001R5100? Enquire Now

FAQs

Mount the device on TH35-15 or TH35-7.5 DIN rails, using the two diagonal M4 screws for secure attachment. Wire the main circuit terminals with flexible or rigid conductors within 1/2 x 2.5–10 mm², and use screw terminals for reliable termination. Ensure coil connections follow the 400–415 V (50 Hz) or 480 V (60 Hz) control voltage ratings.
AC-1 at 690 V: up to 50 A (60 °C–42 A; 70 °C–37 A). AC-3 at 415 V: 38 A; at 440 V: 38 A; at 500 V: 33 A; at 690 V: 24 A; at 380/400 V: 38 A; at 220/230/240 V: 40 A. Rated power for AC-3 is 18.5 kW at 415 V and up to 22 kW at higher voltages depending on the network.
Yes. The unit supports AC-3 operation with a main circuit rating up to 38 A at 415 V, enabling robust motor starting and control for pumps, fans, and conveyors in typical 380–415 V industrial networks.
It carries IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, CSA, CE, UKCA, CB, CCC, BV, DNV and more. It also provides IP20 protection for coil and main terminals, aligning with global safety standards for industrial equipment.
Low coil power loss (2.4 W per pole AC-1; 1.3 W per pole AC-3) reduces heat and energy use. Long-term reliability is supported by robust mechanical life in typical switching frequencies and compatibility with add-on auxiliary blocks for scalable control, lowering total cost of ownership over the equipment’s life.