ABB 1SBL291501R5100 Block Contactor - IEC/EN 60947-4-1

Part Number: 1SBL291501R5100
Manufacturer
ABB
Part number
1SBL291501R5100

Quick Summary

The ABB 1SBL291501R5100 Block Contactor is a four-pole AC switch for motor control in industrial panels. Engineers often struggle with space constraints, coil-damage risk, and high maintenance cycles in legacy relays. This device complies with CE and UKCA safety marks, UL/CSA general-use standards, and IP20 terminal protection, helping you meet stringent global safety requirements. The approved IEC/EN 60947-4-1 family and UL 60947-4-1 certifications underpin reliable performance in harsh environments and ensure consistent switching under heavy loads. Designed for AFC contactor applications, it pairs compact DIN-rail mounting with extendable auxiliary contact blocks and accessories to shrink panel footprint, reduce wiring complexity, and lower total cost of ownership.

Product Information

Extended Description

1SBL291501R5100 ABB: The AFC38-22-00-51 is a 4-pole (2 N.O + 2 N.C) - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 55 A (IEC AC-1) or 55 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
45 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.393 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 55 A | (690 V) 60 °C 45 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A | (440 V) 60 °C 20 A | (500 V) 60 °C 17.6 A | (690 V) 60 °C 10.5 A | (380 / 400 V) 60 °C 22 A | (220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 11 kW | (500 V) 11 kW | (690 V) 9 kW | (220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 8 V·A | Average Pull-in Value 50 Hz 70 V·A | Average Pull-in Value 60 Hz 66 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.3 W | at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 20 ms | Between Coil De-energization and NO Contact Opening 4 ... 18 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 16 mm² | Rigid 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 55 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF(C)26, AF(C)38, AF26(Z)B, AF38(Z)B 4-pole contactors
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC09 ... AFC38 4-pole contactors | UL-CA Certificate of Compliance AFC09 ... AFC38 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
103 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.411 kg
Package Level 1 EAN
3471523024359
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 4-pole main contacts (2 NO, 2 NC) enable direct control of three-phase motors with built-in fail-safe behavior. Business Impact: reduces wiring complexity and streamlines startup sequencing, lowering installation time and potential wiring errors. Application: ideal for conveyors, pumps, and fans in automated panels. Feature: Coil voltage options of 400-415 V AC at 50/60 Hz or 480 V AC at 60 Hz. Business Impact: allows direct integration with standard control circuits without adapters, decreasing control-system complexity. Application: scalable for mixed-voltage plant environments. Feature: 690 V insulation with screw terminals and IP20 protection. Business Impact: delivers safe, durable operation in industrial settings and simplifies field connections, saving on rewire time. Application: switchgear and machine enclosures subject to vibration. Feature: DIN rail mounting TH35-15 or TH35-7.5 and screw-mount option. Business Impact: enables rapid installation and flexible panel design, reducing commissioning time. Application: compact control panels and retrofit projects with limited space. Feature: Low coil power and fast operate times, with per-pole coil loss of 2.3 W (AC-1) and 0.42 W (AC-3) plus 9–26 ms operate times. Business Impact: minimizes heat generation and energy use, extending component life and lowering energy costs in high-cycle applications. Application: automation lines with frequent switching and tight thermal budgets. Feature: Wide compatibility with AFC contactor family and accessories for extended functions. Business Impact: future-proofs installations by enabling auxiliary contacts and add-ons without replacing the base device. Application: OEMs and systems integrators deploying scalable motor-control solutions.

Get a Quick Quote for a ABB 1SBL291501R5100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL291501R5100? Enquire Now

FAQs

The 1SBL291501R5100 supports DIN rail mounting on TH35-15 or TH35-7.5 rails, providing a quick, space-saving installation. It can also be mounted by screws with two M4 screws placed diagonally, offering flexibility for retrofit projects and panel layouts where DIN-rail is not feasible.
The coil accepts 50 Hz at 400–415 V and 60 Hz at 480 V. This enables direct integration with common control voltages in modern industrial controls without the need for adapters, improving reliability and reducing wiring complexity.
Yes. For AC-1, the device handles up to 55 A at 690 V (40 °C). For AC-3, ratings vary by voltage, including 23.2 A at 220–240 V and 10.5 A at 690 V (60 °C). These specs align with IEC/EN 60947-4-1 guidelines and UL/CSA listings for general use and motor control.
The contactor carries CE and UKCA markings, UL/CSA recognition, and is compliant with IEC 60947-4-1/60947-1 standards. It also provides IP20 protection for terminals. These certifications ensure regulatory compliance across global markets, simplifying procurement for multinational projects and reducing compliance risk.
The four-pole, screw-terminal design with compact 45 mm width and DIN-rail mounting minimizes panel real estate and wiring. Low coil power and fast operate times reduce heat and wear, lowering maintenance needs. Extendable auxiliary blocks improve control flexibility without replacing the base device, delivering a lower total cost of ownership over the life of the installation.