ABB 1SBL296001R2111 Contactor - AF Technology

Part Number: 1SBL296001R2111
Manufacturer
ABB
Part number
1SBL296001R2111

Quick Summary

ABB AF contactor enables reliable motor control for industrial drives and machinery. In harsh factory environments, voltage variation and unstable networks can cause nuisance tripping and reduced equipment life. This AF design tolerates a wide control voltage range of 24-60 Hz AC and 20-60 V DC, minimizing control-system sensitivity and panel energy waste. With IEC 690 V and UL 600 V ratings, plus built-in surge protection, it delivers robust protection and compact integration. The block-type design supports easy expansion with add-on auxiliary contact blocks, while screw terminals simplify field wiring. For equipment builders and maintenance teams, this combination reduces downtime, accelerates commissioning, and lowers total cost of ownership through scalable control options and reliable operation.

Product Information

Extended Description

1SBL296001R2111 ABB: The AF38Z-30-11-21 is a 3 pole - 690 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 18.5 kW / 400 V AC (AC-3) or 25 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRAPR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHNOR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CLABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
Check technical info before ordering
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CNIAB001EXPU
Storage Location
4001
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
COABB001EXPU
Storage Location
4001
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DEAPRMLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DKSER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB003EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EESER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EGAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ESATD001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Lead Time
999 day
Country of Origin
Finland (FI)
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FISER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FRAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GBINS001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GRABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABBRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ITIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NLABB021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NOATDRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
SGIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
TRDMD001EXPU
Storage Location
4001
Country of Origin
Finland (FI)
Criticality
No
Lead Time
999 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USABB251EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
Finland (FI)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
Check technical info before ordering
Product Availability Class
No more available. No replacement
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ZATAD021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
111.5 mm
Product Net Height
86 mm
Product Net Weight
0.39 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 50 A | (690 V) 60 °C 42 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 50 A | (220 V) 3 Poles in Series, 60 °C 42 A | (220 V) 3 Poles in Series, 70 °C 37 A | (72 V) 1-Pole, 40 °C 50 A | (72 V) 1-Pole, 60 °C 42 A | (72 V) 1-Pole, 70 °C 37 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 50 A | (220 V) 3 Poles in Series, 60 °C 42 A | (220 V) 3 Poles in Series, 70 °C 37 A | (72 V) 1-Pole, 40 °C 50 A | (72 V) 1-Pole, 60 °C 42 A | (72 V) 1-Pole, 70 °C 37 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 25 A | (220 V) 3 Poles in Series, 60 °C 25 A | (220 V) 3 Poles in Series, 70 °C 25 A | (72 V) 1-Pole, 40 °C 25 A | (72 V) 1-Pole, 60 °C 25 A | (72 V) 1-Pole, 70 °C 25 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(400 V) 18.5 kW | (415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 2.4 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid Solid 1/2x 2.5 ... 4 mm² | Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWG | Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 22 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 28 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)26/30/38(Z)(B) Contactors (FR)
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF26(Z)(B), AF30(Z)(B), AF(Z)(B)38 3-pole contactors, AFS26, AFS30, AFS38 safety contactors
CCC Certificate
CCC Certificate AF26, AF30, AF38, AF26(Z)B, AF30(Z)B, AF38(Z)B 3 and 4-pole contactors, AFS26, AFS30, AFS38 safety contactors
CQC Certificate
CQC Certificate, Contactor, AF*26, AF*30, AF*38, Made in France | CQC Certificate, Contactor, AF26,AF30,AF38, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France | CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
KC Certificate
KC Certificate AF26...AF38 3-pole contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF(S)09...AF(S)96 contactors, NF contactor relays and accessories with screw,spring and push-in terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
UL Listing Card
E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
121 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.39 kg
Package Level 1 EAN
3471523114814
Package Level 2 Units
box 18 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
14.04 kg
Package Level 3 Units
864 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature: Wide control voltage range. Benefit: Reduces panel energy consumption and minimizes tripping risk in unstable networks. Application: Ideal for conveyors, pumps, and fan assemblies where supply quality varies. Feature: Built-in surge protection. Benefit: Protects power circuits and downstream controllers from transients, lowering maintenance costs. Application: Critical in facilities with unreliable mains and switching loads. Feature: 3-pole 690 V IEC / 600 V UL rating. Benefit: Supports large motor loads with IEC and UL compatibility, enabling unified regional deployment. Application: Motors up to 18.5 kW at 400 V AC (AC-3) or 25 hp at 480 V UL. Feature: Pre-mounted auxiliary contacts and screw terminals. Benefit: Streamlines wiring, reduces assembly time, and simplifies field changes. Application: Panel builders can quickly extend functionality with add-on contact blocks. Feature: AF technology with modular design. Benefit: Easier maintenance and scalable interfaces, lowering total cost of ownership. Application: Suitable for upgrading legacy installations without rewiring entire panels.

Get a Quick Quote for a ABB 1SBL296001R2111

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL296001R2111? Enquire Now

FAQs

Install the 3-pole unit using proper panel mounting and ensure screw terminals are securely torqued to specification. Use the pre-mounted auxiliary contacts for extended control logic, and add-on contact blocks as your system grows. Route control wiring to minimize interference, verify coil voltage tolerance (24-60 Hz AC or 20-60 VDC), and test with the protected surge network in place.
This contactor supports IEC 690 V and UL 600 V ratings, and can control motors up to 18.5 kW at 400 V AC (AC-3) or 25 hp at 480 V UL. It can switch power circuits up to 50 A (AC-1) and accommodates a wide control voltage range, which reduces the need for multiple coil variants in a single installation.
Yes. The AF technology provides a wide control voltage tolerance (24-60 Hz AC and 20-60 VDC), which helps maintain reliable operation despite variations in supply voltage. Built-in surge protection further guards the control circuit and downstream equipment against transients common in fluctuating networks.
The device is designed for IEC 690 V operations and UL 600 V compatibility, with built-in surge protection to support compliance in diverse regions. Its modular, block-type design also facilitates conformance with panel-building practices and standard wiring methods.
The AF contactor delivers measurable ROI through reduced energy waste from the tolerant control voltage range, lower downtime due to surge protection, and simplified wiring from screw terminals and add-on blocks. Its compact, expandable design speeds installation and minimizes spare parts while supporting scalable motor control in evolving systems.