ABB 1SBL297001R1300 DC Contactor - AF38 AF Tech

Part Number: 1SBL297001R1300
Manufacturer
ABB
Part number
1SBL297001R1300

Quick Summary

ABB 1SBL297001R1300 DC Contactor enables reliable motor control in industrial automation applications. In demanding panels, voltage drift and noisy networks can cause nuisance starts and energy waste. The AF38 family commonly aligns with CE and UL regulatory expectations, featuring built‑in surge protection and a wide control voltage range. This device supports modular add‑on auxiliary blocks and accessories, delivering predictable operation in standard control panels while reducing panel space and wiring complexity. By combining robustness with measurable efficiency gains, it helps engineers meet uptime targets and lower energy consumption in evolving automation environments.

Product Information

Extended Description

1SBL297001R1300 ABB: The AF38-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 18.5 kW / 400 V AC (AC-3) or 25 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRAPR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHNOR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CLABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CNIAB001EXPU
Storage Location
4001
Country of Origin
China (CN)
Lead Time
30 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
COABB001EXPU
Storage Location
4001
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DEAPRMLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DKSER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB003EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EESER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EGAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ESATD001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Lead Time
14 day
Country of Origin
France (FR)
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FISER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FRAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GBINS001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GRABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABBRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ITIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NLABB021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NOATDRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
SGIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
TRDMD001EXPU
Storage Location
4001
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USABB251EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Lead Time
35 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USSVCEXPU
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ZATAD021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
45 mm
Product Net Depth / Length
86 mm
Product Net Height
86 mm
Product Net Weight
0.31 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 50 A | (690 V) 60 °C 42 A | (690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 38 A | (440 V) 60 °C 38 A | (500 V) 60 °C 33 A | (690 V) 60 °C 24 A | (380 / 400 V) 60 °C 38 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 50 A | (220 V) 3 Poles in Series, 60 °C 42 A | (220 V) 3 Poles in Series, 70 °C 37 A | (72 V) 1-Pole, 40 °C 50 A | (72 V) 1-Pole, 60 °C 42 A | (72 V) 1-Pole, 70 °C 37 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 50 A | (220 V) 3 Poles in Series, 60 °C 42 A | (220 V) 3 Poles in Series, 70 °C 37 A | (72 V) 1-Pole, 40 °C 50 A | (72 V) 1-Pole, 60 °C 42 A | (72 V) 1-Pole, 70 °C 37 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 50 A | (110 V) 2 Poles in Series, 60 °C 42 A | (110 V) 2 Poles in Series, 70 °C 37 A | (110 V) 3 Poles in Series, 40 °C 50 A | (110 V) 3 Poles in Series, 60 °C 42 A | (110 V) 3 Poles in Series, 70 °C 37 A | (220 V) 3 Poles in Series, 40 °C 25 A | (220 V) 3 Poles in Series, 60 °C 25 A | (220 V) 3 Poles in Series, 70 °C 25 A | (72 V) 1-Pole, 40 °C 25 A | (72 V) 1-Pole, 60 °C 25 A | (72 V) 1-Pole, 70 °C 25 A | (72 V) 2 Poles in Series, 40 °C 50 A | (72 V) 2 Poles in Series, 60 °C 42 A | (72 V) 2 Poles in Series, 70 °C 37 A | (72 V) 3 Poles in Series, 40 °C 50 A | (72 V) 3 Poles in Series, 60 °C 42 A | (72 V) 3 Poles in Series, 70 °C 37 A
Rated Operational Power AC-3 (Pe)
(400 V) 18.5 kW | (415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 2.4 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms | Between Coil De-energization and NO Contact Opening 11 ... 95 ms | Between Coil Energization and NC Contact Opening 38 ... 90 ms | Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | Flexible with Insulated Ferrule 2x 1.5 ... 4 mm² | Rigid Solid 1/2x 2.5 ... 4 mm² | Rigid Stranded 1/2x 2.5 ... 10 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 14 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 2.5 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 50 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 10 hp | (240 V AC) Single Phase 5 hp | (440 ... 480 V AC) Three Phase 25 hp | (550 ... 600 V AC) Three Phase 30 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 14-10 AWG | Rigid Stranded 1/2x 14-8 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 22 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 28 A | (240 V AC) Single Phase 28 A | (440 ... 480 V AC) Three Phase 34 A | (550 ... 600 V AC) Three Phase 32 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g | Open, Shock Direction: B1 5 g | Shock Direction: A 30 g | Shock Direction: B2 15 g | Shock Direction: C1 25 g | Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
2d7bf7fd-e890-4c56-9ec9-a7c7ddde44d3 China (CN)
Simplified SCIP
bb5349f2-1cfe-492b-bc8f-ff5346a1b81f Hungary (HU) | 42f841dc-8a79-4c6b-9ed6-c1d09f8819f7 Netherlands (NL) | 00585730-f045-4ac9-a87e-9af3535da08b Norway (NO) | 282621c6-cde9-4308-abb0-2028c03c7eb2 Croatia (HR) | defe27f6-ca84-4675-8133-66a1bb26038e Czech Republic (CZ) | eb09b15d-e5b9-43c6-956c-09a8d5f3549c Germany (DE) | 1afd5218-df16-4b2c-90e4-54db5e4461b8 Poland (PL) | 54a3e158-0bd6-45c2-b322-1b29b1cd6ea5 Poland (PL) | 7e0aa955-a385-48b0-a6a9-bbe7b6ea4162 Belgium (BE) | a47cc456-ef56-4722-a026-11c8884870b5 Germany (DE) | 52b54a02-29e6-462b-bf6d-dd587338f5e0 France (FR) | 9b9b6f33-f42e-40ad-9270-c989dc009b29 Portugal (PT) | 7ba86584-78a7-4b9e-a37c-f31715964c1b Germany (DE) | f3e2f191-52ab-4fc1-a30e-89f8ab7c6444 Poland (PL) | 47818eee-d784-4ea4-8cbc-707ee9ae2b88 Germany (DE) | 05d31a08-ab04-4e32-a2ef-97313540e2c5 Germany (DE) | e68e3c92-c5ed-4eb4-99fd-0032af06f298 Sweden (SE) | 9734939f-e8c2-437a-9f6b-ee9b8758691a Denmark (DK) | 9a462401-c631-4a66-a47f-ff970292d08a Sweden (SE) | 445d4000-fcd7-4642-bc76-7b5fca188cce France (FR) | 5aab79bc-0ff1-4634-baa5-7e2bcb78b1a3 Bulgaria (BG) | 1be41171-3134-4300-8ce8-6d474d85fa6f Greece (GR) | 432ba246-ed46-4be4-8321-900a1b44a142 Finland (FI) | 4cd0d1b6-50d5-4434-9eca-ece3dca5fb88 Hungary (HU) | 901b388c-630c-44c7-a5eb-e5287a1a2fec Spain (ES) | 80778ae3-510a-4410-8c25-21c439724070 Belgium (BE) | 06fff3fd-27aa-42fc-9b7d-c2446cad47e7 Estonia (EE)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End of life instruction AF(S)09/12/16/26/30/38(Z)(B)(K)(RT) Contactors & NF(Z)(B)(K)(RT) Contactors relays
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)26/30/38(Z)(B) Contactors (FR) | Environmental Product Declaration AF26/30/38(Z)(B) Contactors (CN)
Sustainable Material Content in Packaging (wt. %)
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28 %
A2L Certificate – UL
UL-US A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA A2L LZGH2 Certificate of Compliance AF09 ... AF38 3-pole contactors with screw terminals - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV Certificate AF(C)09...AF(C)38 3-pole and 4-pole contactors with screw and Push-in Spring terminals
CB Certificate
CB Certificate AF26(Z)(B), AF30(Z)(B), AF(Z)(B)38 3-pole contactors, AFS26, AFS30, AFS38 safety contactors
CCC Certificate
CCC Certificate AF26, AF30, AF38, AF26(Z)B, AF30(Z)B, AF38(Z)B 3 and 4-pole contactors, AFS26, AFS30, AFS38 safety contactors
CQC Certificate
CQC Certificate, Contactor, AF*26, AF*30, AF*38, Made in France | CQC Certificate, Contactor, AF26,AF30,AF38, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, AFS26, AFS30, AFS38 Made in France | CCC Declaration of Conformity, Contactor, AF26, AF30, AF38, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
KC Certificate
KC Certificate AF26...AF38 3-pole contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF(S)09...AF(S)96 contactors, NF contactor relays and accessories with screw,spring and push-in terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block | UL-CA Certificate of Compliance AF(C)(S)09(R/M/N)-..(L)(S)(K)...AF(C)(S)38(R/M/N)..(K) 3-pole contactors screw, spring and push-in spring terminals; LDC4 additional coil terminal block; LF16-4, LG16-4, LF38-4 and LH38-4 connecting strips, LD38-4 additional terminal block
UL Listing Card
E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
87 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.31 kg
Package Level 1 EAN
3471523111530
Package Level 2 Units
box 21 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
13.95 kg
Package Level 3 Units
1080 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706309
E-Number (Sweden)
3211386
Feature → AF38 AF technology with a wide control voltage range of 100-250 V (AC/50/60 Hz and DC) reduces panel energy consumption and simplifies wiring. Business Impact → Stable operation across voltage variations lowers nuisance trips and improves line uptime. Application → Suitable for AC-3 motor control in manufacturing lines and processing plants. The AF38 design offers a compact, block-type footprint and compatibility with add-on auxiliary contact blocks, enabling scalable control architectures. Application → Fast panel integration and future expansion without replacing the core device. Feature → Built-in surge protection enhances protection against voltage spikes and transient events. Business Impact → Minimizes component wear, extends device life, and reduces maintenance costs. Application → Critical in equipment exposed to grid disturbances or in remote installations. Feature → 3-pole construction up to 690 V IEC / 600 UL and load capacity up to 50 A (AC-1). Business Impact → Enables safe, reliable switching of large motors up to 18.5 kW at 400 V AC. Application → Industrial fans, pumps, and conveyors in mid-sized automation lines. Feature → Screw terminals for robust, vibration‑resistant wiring. Business Impact → Improves electrical connection reliability and reduces re‑work during panel commissioning. Application → Harsh factory environments where conductor integrity is essential. Feature → Wide accessory compatibility and straightforward maintenance. Business Impact → Lower total cost of ownership through easier serviceability and reduced downtime. Application → Reliable integration into existing ABB AF38 ecosystems and control panels.

Get a Quick Quote for a ABB 1SBL297001R1300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL297001R1300? Enquire Now

FAQs

The 1SBL297001R1300 supports standard ABB AF38 mounting and screw-terminal wiring, making it straightforward to swap into existing AF38 panel footprints. Verify coil voltage (100-250V AC/DC) and ensure correct auxiliary contact configuration for your control circuit. Use compatible add-on blocks to match required I/O without rewiring the core device.
This 3-pole contactor is rated for up to 690 V IEC / 600 UL, with a control coil range of 100-250V (AC/50/60 Hz and DC). It supports motor control up to 18.5 kW at 400 V AC (AC-3) and 50 A (AC-1) with surge protection built in, enabling reliable starts in fluctuating networks.
Yes. The device is designed for AC-3 motor control, enabling direct switching of motor circuits up to 18.5 kW at 400 V and 50 A for general use. Its AF38 design and surge protection help ensure reliable operation in demanding manufacturing environments.
ABB AF38 contactors are produced to align with major global standards for industrial control devices. While specific certifications can vary by region, typical affirmations include compliance with IEC/NEMA expectations and safety/regulatory requirements embracing CE/UL expectations for control components in EU and US markets.
Expect reduced downtime due to surge protection and voltage tolerance, predictable extension of contact life, and easier maintenance thanks to screw terminals and modular accessory options. The ability to add auxiliary blocks without replacing the core device lowers total cost of ownership while supporting scalable automation architectures.