ABB 1SBL301001R8100 Block Contactor - IEC 60947-4-1
Part Number: 1SBL301001R8100
Quick Summary
Block Contactor 1SBL301001R8100 is engineered to reliably switch motor circuits in industrial automation. This solution addresses downtime and wiring complexity by delivering robust performance and straightforward wiring in control panels. It carries IEC/EN 60947-4-1 and UL 60335-2-40 certifications, with CSA and CE/UKCA declarations that support global compliance in equipment builds. For panel builders and machine integrators, the compact DIN-rail footprint and 24 V control coil translate to faster installations, easier field maintenance, and lower total cost of ownership. With 3 NO main contacts and a 690 V main circuit rating, it supports a wide range of motors while maintaining safety and efficiency in demanding environments.
Product Information
Extended Description
1SBL301001R8100 ABB: AFC78-30-00-81 24V 50/60Hz Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
55 mm
Product Net Depth / Length
119.5 mm
Product Net Height
111 mm
Product Net Weight
0.98 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 105 A | (690 V) 60 °C 90 A | (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 70 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(400 V) 60 °C 80 A | (415 V) 60 °C 70 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 50 Hz 24 V | 60 Hz 24 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 4 W
Operate Time
Between Coil De-energization and NC Contact Closing 6 ... 19 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 3 ... 16 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 90 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 5 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 7-1/2 hp | (440 ... 480 V AC) Three Phase 60 hp
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 56 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 g | Closed, Shock Direction: B1 25 g | Closed, Shock Direction: B2 15 g | Closed, Shock Direction: C1 25 g | Closed, Shock Direction: C2 25 g | Open, Shock Direction: B1 5 g
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AFC40 ... AFC96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AFC40 ... AFC96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC78 3-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC78 3-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC78 3-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
3471523026360
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three-pole, three NO main contacts rated up to 690 V. Business Impact: Enables reliable, high-current motor switching with ample headroom for peak loads. Application: Conveyor drives, pumps, and machine tools in harsh factory floors. Feature: 24 V control coil with measured coil consumption. Business Impact: Lower control power and energy use reduces wiring heat and panel cooling needs. Application: Control circuits in compact control panels and PLC interfaces. Feature: IEC/EN 60947-1, IEC/EN 60947-4-1 and UL/CSA certifications. Business Impact: Simplifies global compliance, speeding approvals and time-to-market. Application: Equipment destined for multi-region installations. Feature: High mechanical and electrical switching frequency. Business Impact: Extends service life in high-cycle applications, reducing maintenance intervals. Application: Packaging lines, stamping machines, and material handling systems. Feature: DIN rail mounting (TH35-15 or TH35-7.5) and screw terminals. Business Impact: Fast, flexible installation with versatile wiring options, minimizing field commissioning time. Application: Electrical cabinets and automation panels across modern factories. Feature: Compact footprint (55 mm width) with defined dimensions and weight. Business Impact: Optimizes panel space and simplifies enclosure design. Application: OEM panel build-outs and retrofits where space is at a premium. Feature: Robust environmental ratings and IP considerations. Business Impact: Reliable operation from -40 to 70 °C and up to 3000 m altitude with appropriate clearances. Application: Outdoor or harsh indoor environments where temperature variation is common.
Get a Quick Quote for a ABB 1SBL301001R8100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL301001R8100?
Enquire Now
FAQs
Mount the device on a TH35-15 or TH35-7.5 DIN rail. Use 2 x M4 or 2 x M6 screws placed diagonally for secure mounting. Main circuit terminals accept flexible with ferrule 1/2x4...35 mm² or rigid 1/2x6...35 mm²; control circuit accepts 1/2x0.75...2.5 mm² or rigid 1/2x1...2.5 mm². Wire stripping length is 16 mm for the main circuit and 10 mm for the control circuit. Terminals are IP10 (main) and IP20 (aux/main) with standard tightening torques of 4 N·m (main) and 1.2 N·m (control).
Main circuit rated voltage is 690 V with a 50/60 Hz frequency. The coil is 24 V (control circuit). Rated operational currents include AC-1 up to 105 A at 690 V (40 °C) and AC-3 up to 80 A at 415–440 V (60 °C). Coil power includes holding value around 20 V·A and pull-in values of 150–151 V·A depending on frequency. Short-time withstand and breaking capacities are designed for robust motor control, with life cycles suited to industrial duty.
Yes. The device supports AC-3 and AC-3e operation with up to 80 A at typical 400–415 V conditions and provides 45 kW at appropriate voltages for AC-3, making it suitable for motor starters in conveyor systems, pumps, and machine tools. With 3 NO main contacts and 3 poles, it is well-matched for three-phase motor control in standard industrial applications.
The contactor complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, CSA C22.2 No. 60947-4-1, CE, and UKCA declarations, along with CCC and other relevant certificates. These certifications streamline global approvals for equipment in multiple regions, reducing the need for multiple device variants and accelerating time-to-market.
Low coil power and defined power losses (7 W per pole at AC-1, 4 W per pole at AC-3) contribute to lower energy consumption in control circuits. Its high mechanical/electrical switching frequency and durable construction reduce downtime and maintenance costs. The compact footprint and DIN rail mounting speed up panel assembly, supporting faster installations and improved overall equipment efficiency (OEE).