ABB 1SBL301001R8500 Block Contactor - IEC/UL/CSA
Part Number: 1SBL301001R8500
Quick Summary
ABB 1SBL301001R8500 is a high-capacity 3-pole block contactor designed for motor control in industrial automation. This device enables reliable switching of inductive loads at up to 690 V mains with 50/60 Hz operation, helping keep critical machinery running. The design addresses common downtime challenges by combining robust contact insulation, precise coil voltage compatibility, and compact DIN-rail mounting. Key certifications such as IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 60947-4-1, and CE/UKCA declarations provide clear compliance for global installations. In addition to meeting strict standards, the unit offers straightforward installation and maintenance advantages, delivering operational efficiency and predictable performance for OEMs and panel builders alike. This makes it a practical choice for modern industrial control panels needing dependable motor control.
Product Information
Extended Description
1SBL301001R8500 ABB: AFC78-30-00-85 380-400V50Hz 400-415V60Hz Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
55 mm
Product Net Depth / Length
119.5 mm
Product Net Height
111 mm
Product Net Weight
0.98 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 105 A | (690 V) 60 °C 90 A | (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 70 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(400 V) 60 °C 80 A | (415 V) 60 °C 70 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 380 ... 400 V | 50 Hz 380 ... 400 V | 60 Hz 400 ... 415 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 4 W
Operate Time
Between Coil De-energization and NC Contact Closing 6 ... 19 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 3 ... 16 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 90 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 5 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 7-1/2 hp | (440 ... 480 V AC) Three Phase 60 hp
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 56 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 g | Closed, Shock Direction: B1 25 g | Closed, Shock Direction: B2 15 g | Closed, Shock Direction: C1 25 g | Closed, Shock Direction: C2 25 g | Open, Shock Direction: B1 5 g
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AFC40 ... AFC96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AFC40 ... AFC96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC78 3-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC78 3-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC78 3-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
3471523026414
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application ABB 3P contactor with main circuit rated up to 690 V enables reliable motor starting and protection for pumps, fans, and conveyors. This translates to reduced nuisance trips, improved uptime, and safer, controlled switching in demanding environments. Application: suitable for AC-1 and AC-3 duty on 380/400 V and 415 V systems, supporting standard IEC 60947-4-1 control schemes in manufacturing lines. Feature → Compact DIN-rail mounting TH35-15 or TH35-7.5 reduces panel depth and speeds deployment in new builds and refurbishments. Benefit: faster assembly, easier retrofits, and cleaner wiring in compact control cabinets. Application: ideal for space-constrained OEM panels where mounting flexibility matters. Feature → Screw terminals on main and coil circuits with IP ratings (Main Terminals IP10, Coil Terminals IP20) improve wiring integrity and safety. Benefit: robust connections reduce maintenance cycles and improve reliability in harsh factory floors. Application: suitable for high-vibration environments and environments requiring strict protection levels. Feature → High thermal and current ratings including Ith at 105 A and Ie up to 105 A (AC-1) / 80 A (AC-3) at 60 °C. Benefit: supports heavier motor loads with predictable thermal performance, lowering risk of overheating and nuisance trips. Application: motor starters for conveyors and hoists with dense loading. Feature → Low coil consumption and defined pull-in/holding values (50/60 Hz hold 20 VA; pull-in around 150–151 VA). Benefit: reduced coil energy costs and improved energization efficiency in control circuits, enabling smaller control transformers. Application: energy-conscious panel designs in continuous operation. Feature → Comprehensive compatibility with UL/CSA/CE declarations and multiple certifications. Benefit: simplifies procurement and ensures conformity across markets, accelerating project approvals. Application: global deployments requiring certified components. Feature → Clear wiring capacity for flexible/ferrule and rigid conductors (4–35 mm² main; 0.75–2.5 mm² control). Benefit: versatile wiring options reduce termination labor and allow fast, secure installations. Application: large scale panel builds and retrofit projects. Feature → Wide operating temperature and altitude tolerance, with -40 to 70 °C ambient range and up to 3000 m altitude without derating. Benefit: resilience for outdoor or industrial spaces with temperature swings and high elevations. Application: mining, water treatment, and outdoor equipment enclosures. Feature → Rich documentation and data access (datasheets, installation instructions, contactors guides). Benefit: supports faster engineering validation and safer commissioning. Application: design-validation workflows inside engineering teams.
Get a Quick Quote for a ABB 1SBL301001R8500
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL301001R8500?
Enquire Now
FAQs
Install on DIN rail TH35-15 or TH35-7.5 as per IEC 60715. Use 2 x M4 or 2 x M6 screws diagonally if mounting screws are used. Main circuit connections accept flexible ferrule 1/2 x 4–35 mm² or rigid 1/2 x 6–35 mm², with a 16 mm wire strip length for the main circuit.
Main circuit rated at 690 V with 50/60 Hz. Rated operational current AC-1 is 105 A at 40 °C, 90 A at 60 °C, and 80 A at 70 °C. AC-3 current is 80 A at 415 V (and similar values at other voltages). Short-time withstand and breaking capacities support reliable motor starting in demanding loads.
The device carries IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and CE/UKCA declarations. It also has UL/CSA household appliance compatibility certifications and distributor-ready declarations for global deployment in markets requiring UL/CE/UKCA compliance.
Yes. It supports maximum operating altitude without derating up to 3000 meters and operates over a wide ambient temperature range from -40 to 70 °C (with storage conditions extending further). This makes it suitable for outdoor or harsh industrial environments.
Main terminals accept flexible or rigid conductors with screw terminals rated IP10, while control terminals are IP20. The unit supports easy wiring with ferrule options and provides clear torque values (Main 4 N·m, Control 1.2 N·m).-IP ratings and robust mounting reduce maintenance needs and improve reliability in vibration-prone environments.