ABB 1SBL321074R2610 Block Contactor - 690 V CE UL

Part Number: 1SBL321074R2610
Manufacturer
ABB
Part number
1SBL321074R2610

Quick Summary

Block Contactor from ABB is a robust AC switch that controls 3-phase motors in industrial power circuits. Engineers often face panel space constraints and retrofit challenges when upgrading motor control in existing machines. This design carries CE and UL certifications and an IP20 protection rating for coil terminals, aligning with safety and regulatory requirements. With its compact block form and broad accessory availability, it offers installation efficiency and scalable automation potential. By selecting this device, machinery builders reduce wiring complexity and improve downtime resilience across applications in process and packaging lines. In short, it supports reliable, compliant motor control in demanding industrial environments.

Product Information

Extended Description

1SBL321074R2610 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 60 A | (690 V) 40 °C 60 A | (690 V) 70 °C 42 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 40 A | (440 V) 55 °C 37 A | (500 V) 55 °C 33 A | (690 V) 55 °C 25 A | (380 / 400 V) 55 °C 40 A | (220 / 230 / 240 V) 55 °C 40 A
Rated Operational Current AC-15 (Ie)
(690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 105 V | 60 Hz 110 ... 127 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 60 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 15 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 30 hp | (550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 42 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 41 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522401267
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main poles and one built-in auxiliary contact simplify wiring and fault isolation. Benefit: Reduces panel wiring complexity while increasing reliability for 3-phase motor circuits. Application: Useful in conveyor systems and machine controls where space is at a premium and robust interlocks are required. Feature: Control circuit is AC operated with a 50/60 Hz coil voltage option. Benefit: Seamless integration with standard low-voltage automation and PLC outputs, minimizing control panel redesign. Application: Widely used in automated packaging lines and process equipment. Feature: Add-on auxiliary contact blocks support front or side mounting and a wide range of accessories. Benefit: Scales the control logic without replacing the main device, reducing downtime during upgrades. Application: Ideal for customized control schemes in now-versus-next generation machines. Feature: Rated insulation voltage 690 V and multiple current ratings (AC-1, AC-3, AC-15) across voltages. Benefit: Enables one device to serve diverse motor loads, improving spare part commonality. Application: Suitable for motors up to 690 V in heavy-duty industrial plants. Feature: IP20 protection on coil terminals and low power loss per pole. Benefit: Safer operating conditions inside control cabinets with cooler, energy-efficient operation. Application: Fits in compact panels with tight thermal management. Feature: Compact block design with 54 mm width, 90 mm depth, and 108.3 mm height; weight 0.667 kg. Benefit: Easier installation, reduced cabinet footprint, and straightforward handling during maintenance. Application: Preferred in space-constrained installations across manufacturing floors.

Get a Quick Quote for a ABB 1SBL321074R2610

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL321074R2610? Enquire Now

FAQs

The ABB block contactor uses screw terminals and supports front or side mounting for add-on auxiliary contacts. This allows straightforward installation in space-constrained panels and easy integration with existing AX32/AX40 accessory ecosystems, reducing wiring complexity and enabling quick upgrades in machine controls.
For AC-3 operation at 690 V and 55 °C, the contactor provides up to 25 A; at 415 V it reaches around 40 A. AC-1 ratings reach up to 60 A (at lower voltages) depending on line voltage and ambient conditions. These figures support reliable motor switching for common industrial loads.
Yes. The AX40 family carries CE conformity and UL certifications, with rated insulation voltage of 690 V and IP20 coil terminal protection, making it appropriate for motor circuits up to 690 V in compliance-driven environments.
The coil variants include 50 Hz at 105 V and 60 Hz at 110–127 V, enabling compatibility with common control circuits and PLC outputs. This supports reliable energization across regional power profiles without panel rewiring.
Key factors include low power loss per pole (3 W AC-1, 1.3 W AC-3), tight terminal torque values (auxiliary 1 N·m, main 2.3 N·m), and IP20 protection. These features reduce energy use, simplify maintenance, and extend service intervals, delivering lower total cost of ownership in automation projects.