ABB 1SBL321074R3601 Block Contactor - 690V 60A

Part Number: 1SBL321074R3601
Manufacturer
ABB
Part number
1SBL321074R3601

Quick Summary

Block Contactor ABB 1SBL321074R3601 provides robust motor control for 3‑phase systems in demanding industrial environments. Many facilities struggle with motor startup surges and unplanned downtime, which can accelerate wear and reduce throughput. This device switches main circuits up to 690 V AC with 3 main poles and a built‑in auxiliary contact, and supports add‑on auxiliary blocks for flexible control configurations. It carries CE conformity with RoHS compliance and is listed for UL/CSA and CCC in applicable variants, with IP20 protection on terminals. For engineers, this combination translates to easier installation, reduced wiring complexity, and a clearer path to scalable control architectures and spare‑parts inventories.

Product Information

Extended Description

1SBL321074R3601 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 60 A | (690 V) 40 °C 60 A | (690 V) 70 °C 42 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 40 A | (440 V) 55 °C 37 A | (500 V) 55 °C 33 A | (690 V) 55 °C 25 A | (380 / 400 V) 55 °C 40 A | (220 / 230 / 240 V) 55 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V | 60 Hz 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 60 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 15 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 30 hp | (550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 42 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 41 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522402363
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
The 1SBL321074R3601 features a compact block design that reduces panel depth while maintaining high switching capacity, delivering measurable space savings in control cabinets and MCCs. This translates to lower enclosure costs and easier cable routing in confined installations, supporting long‑term maintenance programs and faster commissioning. The 3‑pole main contacts and 1 NC auxiliary contact provide robust motor control for AC‑3 and AC‑1 applications, enabling reliable startup sequences and smoother live‑line switching in conveyors, pumps, and fans. Its rated control circuit voltage of 190 V at 50 Hz or 220 V at 60 Hz aligns with standard European and North American control systems, minimizing the need for voltage adapters and reducing wiring errors. Compatibility with add‑on auxiliary blocks offers front or side mounting flexibility, improving fault diagnostics and expandability. The device’s IP20 protection and screw terminal design simplify installation and field servicing, while low power loss per pole enhances overall system efficiency and reduces heat generation in confined spaces. With wide operating temperatures and a 65 A short‑time current rating, it remains reliable in rugged factory environments where uptime matters most. Industry‑leading certifications, RoHS compliance, and available CAD drawings streamline procurement, engineering validation, and maintenance planning, supporting a lower total cost of ownership. As a result, end users gain improved machine reliability, faster downtime recovery, and a scalable footprint for future motor control needs.

Get a Quick Quote for a ABB 1SBL321074R3601

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL321074R3601? Enquire Now

FAQs

For installation, plan a 3‑pole main circuit with a single NC auxiliary contact and space for add‑on auxiliary blocks if future expansion is expected. Use screw terminals with a torque of 2.3 N·m on main terminals and 1 N·m on auxiliary/control terminals. Ensure IP20 protection is maintained by proper enclosure sealing and clean wiring practices. The unit supports 190 V or 220 V control voltage depending on frequency, simplifying integration with existing controls.
At 690 V AC, the contactor provides a rated operational current Ie of 25 A for AC‑3 loads with a 55 °C ambient limit, and a rated pole power capacity of up to 22 kW (AC‑3). It also supports 60 A Ie in lower‑voltage configurations and up to 60 A for AC‑1 operations at 690 V. These ratings enable reliable motor starts for medium‑size fans, pumps, and small compressors, with margin for short‑time surge currents as defined in the datasheet.
Yes, the AX40 family supports add‑on auxiliary contact blocks for front or side mounting. This compatibility simplifies control logic expansion without changing the main wiring, enabling additional signaling or interlocks as systems scale. The benefit is reduced debugging time, easier customization for different motor startup schemes, and a cleaner, modular control cabinet design that accommodates evolving control strategies without major rewiring.
The AX32/AX40 range, including 1SBL321074R3601, carries CE conformity with EU declarations and RoHS compliance. It is listed with UL/CSA in applicable variants and has CCC documentation for the Chinese market. Documentation includes CCC Declaration of Conformity and UL Certificates for related AX models. This mix supports global procurement, regulatory alignment, and smoother cross‑border deployment in mixed compliance environments.
Maintenance benefits from a compact footprint, IP20 terminals for protection, and screw‑type terminals that simplify field servicing. With low power loss per pole (3 W AC‑1, 1.3 W AC‑3) and a 65 A Ith rating, cooling needs are modest, reducing energy waste and extending device life. The modular design with add‑on auxiliary blocks reduces spare parts variety, lowering inventory costs and improving MTTR during maintenance windows.