ABB 1SBL321074R8001 Block Contactor - CE/UL Certified

Part Number: 1SBL321074R8001
Manufacturer
ABB
Part number
1SBL321074R8001

Quick Summary

ABB Block Contactor 1SBL321074R8001 enables efficient control of 3-phase motors up to 690 V in industrial equipment. Engineers often face startup transients and a need for reliable auxiliary signaling; this device addresses those challenges with a robust three-pole design and a single NC auxiliary contact for clear feedback. The product carries CE, UL, and CB/CCC conformity markings, ensuring regulatory alignment across global markets. For OEMs and panel builders, its compact footprint and compatibility with add-on auxiliary blocks translate into faster assemblies, easier wiring, and reduced panel depth, delivering tangible uptime and lifecycle savings without compromising safety.

Product Information

Extended Description

1SBL321074R8001 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 60 A | (690 V) 40 °C 60 A | (690 V) 70 °C 42 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 40 A | (440 V) 55 °C 37 A | (500 V) 55 °C 33 A | (690 V) 55 °C 25 A | (380 / 400 V) 55 °C 40 A | (220 / 230 / 240 V) 55 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 60 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 15 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 30 hp | (550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 42 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 41 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522402806
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707346
Feature → Business Impact → Application: Three main NO contacts plus one NC auxiliary contact simplifies motor control logic and feedback, reducing wiring complexity and potential fault points in control circuits; ideal for standard 3-phase motor drives in packaging, conveyors, and factory automation. Feature → Operational voltage and frequency compatibility → Ensures reliable actuation across 50/60 Hz mains and 690 V systems, supporting global installations and scalable machine designs. Feature → 3-pole block design with optional add-on auxiliary blocks → Enhances expandability for front or side mounting, enabling tailored control schemes and future-proofing panels. Feature → Rated operational currents AC-3 up to 40 A at 690 V and AC-1 up to 60 A (varies by voltage) → Delivers predictable switching performance for motor reviews and load profiles, improving equipment uptime and reducing maintenance costs. Feature → Insulation voltage 690 V and high short-time withstand capability → Meets stringent safety standards and supports high inrush conditions common in hoisting, extruders, and pumps. Feature → Compact dimensions (54 mm wide, 90 mm deep, 108.3 mm high) and 0.667 kg weight → Facilitates dense panel layouts and easier installation in tight electrical cabinets. Feature → Operate time and mechanical switching frequency → Ensures responsive control in high-cycle applications while maintaining reliability over long-term operation.

Get a Quick Quote for a ABB 1SBL321074R8001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL321074R8001? Enquire Now

FAQs

The contactor supports coil voltages of 220–230 V at 50 Hz and 230–240 V at 60 Hz. This dual-range coil enables operation with standard European mains without additional adapters, simplifying replacement in existing installations and reducing inventory needs.
Yes. It is designed to switch main circuits up to 690 V AC and provides a rated insulation voltage of 690 V, along with appropriate current ratings (AC-3 up to 40 A at 690 V). This makes it suitable for many standard motor control applications in industrial automation.
This ABB contactor carries CE and UL certifications, with additional conformance marks such as CB and CCC. These certifications support global deployment, simplify supplier declarations, and help meet local electrical and safety regulations in many manufacturing regions.
Yes. The AX32/AX40 family design permits add-on auxiliary contact blocks for front or side mounting, enabling expanded signaling and control options without replacing the base unit. This helps tailor the device to specific control architectures and future upgrades.
The unit uses screw terminals with a tightening torque of 2.3 N·m for main circuits and 1 N·m for auxiliary and control circuits, ensuring secure connections. Its IP20 protection and compact 54 mm width support reliable operation in protected industrial cabinets, while its thermal/current ratings guide appropriate panel cooling and lifecycle planning.