ABB 1SBL321074R8301 Block Contactor - 690V UL/CE

Part Number: 1SBL321074R8301
Manufacturer
ABB
Part number
1SBL321074R8301

Quick Summary

ABB 1SBL321074R8301 block contactor is designed to control three-phase motors and power circuits up to 690 V AC in demanding industrial environments. This solution helps engineers avoid downtime by delivering a compact, reliable switching device that fits standard control panels. The family carries CE, UL/CSA, and CCC declarations, plus CB certificates and RoHS/REACH compliance to support global deployment. With a 54 mm width, 90 mm depth, and 108.3 mm height and a 48 V control coil, it reduces wiring complexity while delivering robust operating performance for automotive, material handling, and process automation applications.

Product Information

Extended Description

1SBL321074R8301 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 60 A | (690 V) 40 °C 60 A | (690 V) 70 °C 42 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 40 A | (440 V) 55 °C 37 A | (500 V) 55 °C 33 A | (690 V) 55 °C 25 A | (380 / 400 V) 55 °C 40 A | (220 / 230 / 240 V) 55 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 60 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 15 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 30 hp | (550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 42 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 41 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522402837
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main NO contacts and one NC auxiliary contact enable straightforward motor control and status feedback. Business Impact: Reduces external relays and wiring, lowering panel cost and potential fault points. Application: Ideal for 3-phase motors in conveyors and pumps up to 690 V AC with reliable auxiliary feedback. Feature: 48 V control circuit voltage at 50/60 Hz and AC-operated coil. Business Impact: Simplifies control wiring from PLCs and safety circuits while delivering fast, repeatable coil energization. Application: Compatible with standard 48 V control logic in industrial PLC environments. Feature: Compact footprint 54 mm wide, 90 mm deep, 108.3 mm high and mass of 0.667 kg. Business Impact: Saves panel space and allows flexible mounting in tight control cabinets. Application: Easy retrofits into existing enclosures without reworking layout. Feature: Rated Operational Currents (AC-1 up to 60 A; AC-3 up to 25 A at 690 V). Business Impact: Supports efficient motor control with predictable start/stop profiles, reducing component counts and energy loss. Application: Suitable for high-performance drives and mechanical load switching. Feature: Power loss as low as 3 W per pole (AC-1) and 1.3 W per pole (AC-3). Business Impact: Lower heat generation in panels and improved energy efficiency during continuous operation. Application: Long-term reliability in continuous-duty conveyor and pump stations. Feature: Screw terminals with IP20 protection and specified tightening torques. Business Impact: Ensures secure connections and straightforward installation, minimizing maintenance calls. Application: Quick field wiring and robust performance in harsh factory environments.

Get a Quick Quote for a ABB 1SBL321074R8301

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL321074R8301? Enquire Now

FAQs

The unit uses screw terminals with a compact 54 mm width, 90 mm depth, and 108.3 mm height. Plan space for 3 NO main contacts and 1 NC auxiliary contact, ensure IP20 protection, and tighten connections to 1 N·m for auxiliary/control and 2.3 N·m for main circuits. This design supports quick retrofit into standard cabinets and minimizes wiring complexity.
At 690 V, AC-3 rated current is 25 A, and AC-1 rated current is up to 60 A. Other voltage points show higher AC-3 ratings at lower voltages (e.g., 40 A at 415 V, 37 A at 440 V, 33 A at 500 V, and 40 A at 380/400 V). These figures guide safe, compliant motor control for diverse industrial loads.
Yes. The device is designed for three-phase motor control up to 690 V AC, with 3 NO main contacts and 1 NC auxiliary contact, 48 V coil, and AC-3 power ratings suitable for motor starting and switching in conveyor systems. Its compact footprint and robust ratings support reliable, space-efficient automation crawls and line-side switching.
The product carries CE, UL/CSA, and CCC declarations, along with CB-related certifications and RoHS/REACH compliance. Confirm CCC and UL certificates for local market access, and ensure RoHS/REACH conformity for restricted substances in your region. These certifications help simplify cross-border procurement and maintenance planning.
With a low coil power loss of 3 W per pole (AC-1) and 1.3 W per pole (AC-3), heat generation is minimized, supporting longer intervals between replacements. Mechanical switching frequency up to 3600 cycles per hour and electrical endurance for regular start/stop cycles contribute to favorable total cost of ownership in continuous-running applications like conveyors and pumps.