ABB Block Contactor 1SBL321074R8310 controls 3‑phase motors up to 690 V in industrial power circuits. Engineers often face reliability and installation challenges when switching high‑voltage motor loads, especially in compact layouts. This device carries CE, UL and CCC certifications, plus RoHS/REACH compliance, ensuring regulatory adherence and long‑term reliability. With a 3 NO main contact and 1 NO auxiliary contact, a 48 V coil at 50/60 Hz, and screw terminals for straightforward installation, it delivers cost‑effective, scalable motor control for demanding industrial environments.

Product Information

Extended Description

1SBL321074R8310 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 60 A | (690 V) 40 °C 60 A | (690 V) 70 °C 42 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 40 A | (440 V) 55 °C 37 A | (500 V) 55 °C 33 A | (690 V) 55 °C 25 A | (380 / 400 V) 55 °C 40 A | (220 / 230 / 240 V) 55 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 60 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 15 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 30 hp | (550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 42 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 41 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522401830
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3-pole main NO contacts with 1 auxiliary NO contact. Benefit: Enables reliable control of 3-phase motors with a compact footprint, reducing panel space and wiring complexity. Application: Conveyor systems and pump drives where space is at a premium and dependable switching is essential. Feature: Coil voltage 48 V at 50/60 Hz. Benefit: Compatible with common automation control circuits, simplifying integration with PLCs and control relays. Application: Factory automation and process lines using standard control voltages. Feature: Rated main and auxiliary voltages up to 690 V. Benefit: Supports high‑voltage motor loads and broad integration with equipment across industrial plants. Application: Heavy machinery, machine tools, and material handling. Feature: Conventional Free-air Thermal Current Ith of 65 A. Benefit: Higher tolerance to startup and load surges, improving reliability in open ambient environments. Application: Outdoor or exposed control panels where cooling is limited. Feature: Rated Operational Current AC-3 at 690 V up to 25 A. Benefit: Efficiently handles motor start/stop duties with predictable thermal performance. Application: Drivetrains and fans in HVAC, pumps, and compact machinery. Feature: IP20 protection on terminals. Benefit: Dust protection and safe operation in typical indoor cabinets. Application: Control panels and electrical cabinets in manufacturing plants. Feature: Screw terminals and straightforward mounting. Benefit: Simplifies installation, testing, and future upgrades. Application: Retrofit projects and new panel builds with standard terminal hardware. Feature: Add-on auxiliary contact blocks for front or side mounting. Benefit: Flexible control logic expansion without redesigning the panel. Application: Systems requiring expanded interlock or signaling functions. Feature: Certifications and compliance including CE, UL, CCC, RoHS. Benefit: Ensures market acceptance across regions and regulatory compliance for global deployments. Application: Global machinery and equipment deployments requiring multi‑region approvals.

Get a Quick Quote for a ABB 1SBL321074R8310

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL321074R8310? Enquire Now

FAQs

Installation involves wiring the three main NO contacts and the single auxiliary NO contact to your motor control circuit using screw terminals. Tighten main circuit terminals to 2.3 N·m and auxiliary/control terminals to 1 N·m as specified. Mount the unit in a compliant enclosure with IP20 protection on exposed connections to ensure safe operation and ease of maintenance.
For AC-3 operation at 690 V, the device is rated up to 25 A per pole. This supports motor start/stop duty with predictable performance, suitable for drives, conveyors, and other high‑voltage motor loads while maintaining thermal integrity under typical ambient conditions.
Yes. The product carries CE declarations, UL certificates, and CCC documentation, along with RoHS/REACH compliance. These certifications support global deployments, ensuring conformity with European, North American, and Chinese regulatory requirements.
The control coil operates at 48 V with a frequency of 50 Hz or 60 Hz, allowing compatibility with standard control circuits and PLC logic without additional adapters or power supplies.
Best suited for controlling 3-phase motors in conveyors, pumps, and machine tools, particularly where 690 V line voltage, 3-pole main contacts, and a built‑in auxiliary contact are advantageous. Its compact form, accessible screw terminals, and optional auxiliary blocks simplify integration into existing control panels and new equipment.