ABB 1SBL321074R8410 Block Contactor - CE Certified 690V

Part Number: 1SBL321074R8410
Manufacturer
ABB
Part number
1SBL321074R8410

Quick Summary

Block Contactor ABB 1SBL321074R8410 controls 3-phase motors up to 690 V AC. Engineers often struggle with downtime caused by undersized switchgear and miswired control circuits. Key certifications include CE conformity, UL/CSA recognition, and CCC certification to support global compliance. The compact block design plus 3 main poles and 1 NO auxiliary contact simplifies panel layouts, while add-on auxiliary blocks enable front or side mounting for flexible installation. This combination delivers reliable motor control, reduced wiring costs, and faster maintenance in automation lines. Designed for international markets, it supports 50/60 Hz operation and offers predictable coil voltages. Its Ie ratings at 690 V across AC-3 and AC-1 enable motor control decisions aligned with IEC 60947-4-1.

Product Information

Extended Description

1SBL321074R8410 ABB: AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
54 mm
Product Net Depth / Length
90 mm
Product Net Height
108.3 mm
Product Net Weight
0.667 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 60 A | (690 V) 40 °C 60 A | (690 V) 70 °C 42 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 40 A | (440 V) 55 °C 37 A | (500 V) 55 °C 33 A | (690 V) 55 °C 25 A | (380 / 400 V) 55 °C 40 A | (220 / 230 / 240 V) 55 °C 40 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 0.55 A / 60 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 18.5 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 6 ... 18 ms | Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 2.3 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 60 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 10 hp | (220 ... 240 V AC) Three Phase 15 hp | (240 V AC) Single Phase 7.5 hp | (440 ... 480 V AC) Three Phase 30 hp | (550 ... 600 V AC) Three Phase 40 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 20 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 32.2 A | (220 ... 240 V AC) Three Phase 42 A | (240 V AC) Single Phase 40 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 41 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 32~40A CB certification
CCC Certificate
9AKK107492A7090
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX32, AX40, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
65 mm
Package Level 1 Depth / Length
101 mm
Package Level 1 Height
115 mm
Package Level 1 Gross Weight
0.71 kg
Package Level 1 EAN
3471522401847
Package Level 2 Units
12 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
8.52 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707352
The 1SBL321074R8410 uses a robust 3-pole block design with three main NO contacts and a built-in auxiliary NO contact, reducing panel depth and simplifying wiring, which translates to faster installation and lower labor costs on the shop floor. Business impact: streamlined assemblies and improved reliability in motor control and power circuits up to 690 V AC. Application: ideal for 3-phase conveyors, pumps, and machine tools in automated lines, where consistent switching performance lowers downtime and extends motor life. The coil is AC operated with a control circuit voltage of 110 V at 50 Hz or 110–120 V at 60 Hz, enabling straightforward integration with regional control systems. This compatibility minimizes stock variety and improves changeover efficiency during maintenance windows. Feature: add-on auxiliary contact blocks allow front or side mounting and a wide range of accessories, enabling scalable control schemes without rewiring. Business impact: modular flexibility supports future expansion and reduces total cost of ownership. Application: panel builders can tailor the solution to exact control logic while maintaining a compact footprint. The contactor delivers rated operational currents (AC-1 and AC-3) compatible with common motor loads while maintaining low power loss per pole (3 W AC-1, 1.3 W AC-3), contributing to cooler cabinets and energy efficiency. Application: line-side protection with predictable thermal behavior improves overall system reliability. The contactor's electrical and mechanical switching frequencies (AC-1 up to 600 cycles/hour, mechanical up to 3600 cycles/hour) support demanding automation sequences without premature wear. This translates to reduced maintenance intervals and improved uptime. IP20 protection at terminals plus robust torque specifications ensures secure connections and long-term durability in typical industrial environments. Additional compatibility with AX32–AX40 accessory range provides a consistent family fit for mixed motor control topologies, reducing spare parts complexity. Certifications across CE, UL/CSA, and CCC reinforce global compliance with mounting in diverse production sites and supplier audits. The result is a dependable, scalable solution that balances performance, installation ease, and lifecycle cost.

Get a Quick Quote for a ABB 1SBL321074R8410

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL321074R8410? Enquire Now

FAQs

The 1SBL321074R8410 is designed as a 3-pole block contactor in the AX32–AX40 family. It supports add-on auxiliary blocks for front or side mounting, enabling flexible integration into existing control cabinets. When pairing with AX32 or AX40 devices, ensure matching coil voltage (110 V 50 Hz or 110–120 V 60 Hz) and use compatible auxiliary contact blocks to extend logic without rewiring. Proper torque settings and IP20 terminal protection help maintain reliability in dynamic industrial environments.
For 690 V operation, AC-1 current is rated up to 60 A, and AC-3 is rated up to 40 A (depending on ambient temperature). The control coil operates at 110 V for 50 Hz or 110–120 V for 60 Hz. Rated insulation voltage is 690 V, and the unit supports standard control and auxiliary circuits with low power loss per pole. These ratings align with IEC 60947-4-1, ensuring safe and predictable performance in motor control tasks.
The contactor is rated IP20 for terminals, coils, and main terminations, which suits indoor industrial panels with moderate dust exposure. For harsher environments, use enclosure protection or additional filtration to maintain reliability. The device also features a compact 54 mm width and 90 mm depth footprint, enabling flexible installation in tight control cabinets. For elevated altitudes or extreme temperatures, verify ambient conditions in the environmental specifications and consider protective housing if needed.
Key certifications include CE conformity, UL/CSA recognition, and CCC certification, reflecting compliance with European, North American, and Chinese market requirements. These validations support global supply chains and customer audits, reduce compliance risk, and simplify cross-border procurement. When selecting this contactor for multi-region deployments, reference the CCC and CE declarations for documentation and ensure your installation follows IEC 60947-4-1 derivative guidelines for consistent performance.
The 1SBL321074R8410 offers a compact, modular design with three main contacts plus one auxiliary contact, enabling faster panel assembly and reduced wiring complexity. With low power loss per pole and durable switching performance (high mechanical cycling and acceptable electrical switching frequency), maintenance intervals can be extended and downtime reduced. Availability of front/side mounting options and AX32–AX40 accessory compatibility lowers spare parts variety, contributing to lower total cost of ownership and faster implementation in production lines.