ABB 1SBL341201R5100 Block Contactor - IEC 60947-4-1

Part Number: 1SBL341201R5100
Manufacturer
ABB
Part number
1SBL341201R5100

Quick Summary

Block Contactor 1SBL341201R5100 provides four-pole power switching for motor and process control. In demanding panel builds, space constraints and reliability concerns can derail timelines and increase maintenance costs. It complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1/4-1, and CSA standards, with CE and UKCA declarations for global deployment. Designed for easy integration with add-on auxiliary blocks and DIN rail mounting, it delivers scalable control capabilities, reduced wiring complexity, and a clear path to predictable lifecycle costs for OEMs and service teams.

Product Information

Extended Description

1SBL341201R5100 ABB: The AFC40-40-00-51 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 70 A (IEC AC-1) or 60 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 70 A | (690 V) 60 °C 60 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 60 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523024410
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature is four-pole main switching with 690 V rated main circuit and 70 A at 40 °C (60 A at 60 °C, 50 A at 70 °C) enabling reliable AC-1 and AC-3 motor control. Business Impact: supports high-load applications with rated power and defined thermal behavior, reducing downtime and maintenance intervals. Application: ideal for conveyors, pumps, and fans in industrial automation. Feature is coil voltage 400–415 V at 50 Hz / 480 V at 60 Hz, enabling flexible control from common regional grids. Business Impact: simplifies panel design and lowers stocking requirements. Application: cross-region machine builds. Feature is four NO main contacts in a 4P configuration with screw terminals, improving circuit separation and wiring reliability. Business Impact: lowers fault rates and allows straightforward field troubleshooting. Application: large-motor starters and process lines. Feature is DIN rail mounting (TH35-15 or TH35-7.5) and screw mounting options, streamlining installation. Business Impact: reduces commissioning time and enables modular panel layouts. Application: OEM control panels and retrofit projects. Feature is compatibility with add-on auxiliary contact blocks and a broad accessory ecosystem. Business Impact: enables future expansion without replacing the base device. Application: scalable control architectures. Feature is robust standards and declarations program (IEC/EN 60947-1, 60947-4-1; UL/CSA; CE/UKCA). Business Impact: minimizes compliance risk and accelerates approvals in multi-region deployments. Application: any global machine build requiring certified control components.

Get a Quick Quote for a ABB 1SBL341201R5100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL341201R5100? Enquire Now

FAQs

Install via the TH35 mounting options (TH35-15 or TH35-7.5) on a standard 35 mm DIN rail. The device supports screw mounting with 2 x M4 or 2 x M6 screws placed diagonally if DIN rail mounting is not used. Ensure the main terminals are accessible for wiring and tighten to the specified torque. This enables quick, secure installation and simplified panel design.
The 1SBL341201R5100 supports a main circuit rated up to 690 V and a conventional current (Ie) of 70 A at 40 °C, 60 A at 60 °C, or 50 A at 70 °C for AC-1 loads. For AC-3, ratings vary by voltage, with typical values around 40 A at 415 V and similar ranges at other voltages. It also offers a maximum breaking capacity suitable for high-power control tasks.
Yes. The device is designed for a control circuit voltage of 400–415 V at 50 Hz or 480 V at 60 Hz, allowing straightforward integration into regions using standard 400–480 V control supplies. This flexibility reduces the need for additional transformers and simplifies panel design.
The contactor complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, and CSA equivalents. It also carries CE and UKCA declarations, and product certifications such as BV, UL, and DNV where applicable. This broad certification footprint supports global deployments and minimizes regulatory risks in multinational projects.
The 1SBL341201R5100 offers robust mechanical and electrical endurance, including high short-time withstand ratings and low coil consumption, which helps reduce energy use in holding states. Its modular accessory ecosystem allows future expansion with auxiliary contacts without swapping the base unit, lowering lifecycle costs and simplifying spare-part logistics for maintenance teams.