ABB 1SBL341201R8100 Block Contactor - 690V IEC/UL

Part Number: 1SBL341201R8100
Manufacturer
ABB
Part number
1SBL341201R8100

Quick Summary

The AFC40 family 4-pole block contactor 1SBL341201R8100 delivers reliable 690 V AC power switching with a 24 V coil for control in industrial panels and machines. It addresses common wiring and compatibility challenges by offering screw terminals, a block-type design, and easy expansion with add-on auxiliary contact blocks. This device is listed under CE and UL/CSA with protection ratings appropriate for industrial environments, including IP20 on auxiliary terminals and IP10 on main terminals, plus compliance to IEC/EN 60947-4-1 and related standards. The combination of robust performance, DIN-rail mounting readiness, and wide accessory compatibility translates into lower install time and reduced total cost of ownership while keeping future scalability in view.

Product Information

Extended Description

1SBL341201R8100 ABB: The AFC40-40-00-81 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 70 A (IEC AC-1) or 60 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 24 V AC 50 Hz / 24 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 70 A | (690 V) 60 °C 60 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 0 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Operate Time
Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 60 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 3 A | (200 ... 208 V AC) Three Phase 10 A | (220 ... 240 V AC) Three Phase 15 A | (240 V AC) Single Phase 7-1/2 A | (440 ... 480 V AC) Three Phase 30 A | (550 ... 600 V AC) Three Phase 40 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
CQC Certificate
CQC Certificate, Contactor, AF40, AF52, AF65, AFC40, AFC52, AFC65, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523019072
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 4-pole 690 V main circuit supports high-load machine applications up to 70 A AC-1 (40 °C) and 60 A AC-1 (60 °C), enabling compact motor control panels without oversizing components, which reduces panel footprint and material costs. This translates to faster assembly and improved efficiency in conveyors, pumps, and hoisting systems. Feature → Application → Benefit: 24 V coil at 50/60 Hz with coil consumption of 20 V·A holding and 150/151 V·A pull-in ensures predictable energize/de-energize dynamics for reliable control of automation devices and drives, minimizing nuisance tripping and extending equipment life. Feature → Compatibility → Installation: Screw terminals and DIN-rail mounting TH35-15 simplify wiring and mounting, supporting quick retrofits and modular expansions in existing control cabinets with minimal tooling. Feature → Compliance → Risk Management: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1 certification lineage provides regulatory assurance for global deployments, reducing compliance workload for manufacturers and integrators. Feature → Expandability → Future-Proofing: Block design with add-on auxiliary contact blocks and range of accessories enables scalable control architectures without replacing the base component, lowering lifecycle costs in evolving machinery. Feature → Mechanical & Electrical Performance → Reliability: Maximum mechanical 3600 cycles/h and electrical switching up to 600–950 A peak (depending on cos φ) ensure durable operation in demanding automation environments, supporting maintenance planning and uptime targets. Feature → Safety & Handling → Installation Comfort: Screw terminals for main and flexible/rigid conductor options (4–35 mm² flexible; 6–35 mm² rigid) provide robust, vibration-resistant connections suitable for panel installations, reducing rework and warranty issues.

Get a Quick Quote for a ABB 1SBL341201R8100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL341201R8100? Enquire Now

FAQs

The 1SBL341201R8100 supports TH35-15 DIN rail mounting for quick installation in control cabinets and can also be mounted with 2 x M4 or 2 x M6 screws placed diagonally if preferred. This dual mounting compatibility reduces install time and simplifies retrofit projects in existing cabinets.
Main circuit is rated up to 690 V with a conventional AC-1 current of up to 70 A (40 °C) and 60 A (60 °C). AC-3 ratings vary by voltage, with 40 A at 415 V (60 °C) and other combinations up to 25 A at 690 V (60 °C). Coil voltage is 24 V AC (50/60 Hz). These ratings support motor and general power switching in industrial panels.
Yes, the AFC40 family is designed for easy extension with add-on auxiliary contact blocks. This enables expanded control logic without replacing the base device. Wiring remains straightforward since the main terminals use screw connections and the coordination with auxiliary circuits remains consistent, preserving compact panel layouts.
This contactor carries CE and UL/CSA certifications, with conformity to IEC 60947-1 and IEC 60947-4-1. UKCA, CB, CCC, and other certificates are noted in the product story as part of the broader AFC40 family, supporting compliance in multiple regions and simplifying cross-border deployments.
Expect a maximum mechanical switching frequency of 3600 cycles per hour and electrical switching up to 600–950 A cos φ depending on voltage. Coil consumption is defined for holding and pull-in at 50/60 Hz, with 3 W per pole at AC-1 and 1 W per pole at AC-3. Regular inspection of terminal torque (4 N·m main, 1.2 N·m control) helps sustain reliability and minimizes downtime.