ABB AFC40-22-00-34 Contactor is a four-pole power switch designed for AC-1 and AC-3 motor control up to 70 A at 690 V. In practice, field wiring, coil compatibility, and panel space can stall projects; this device mitigates those risks with screw terminals and compact DIN-rail mounting. The product carries CE and UKCA marks along with UL/CSA approvals, plus third-party certifications (BV, CB, DNV, RINA) to support global compliance and audit readiness, while remaining compatible with AFC contactors’ modular accessories. For automation panels and industrial drives, its compact footprint and scalable accessory options deliver efficient, reliable control in demanding environments.
Product Information
Extended Description
1SBL341501R3400 ABB: The AFC40-22-00-34 is a 4-pole (2 N.O + 2 N.C) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 70 A (IEC AC-1) or 60 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 175 V AC 50 Hz / 208 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 70 A | (690 V) 60 °C 60 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 175 V | 60 Hz 208 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 60 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523024427
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 4-pole main contacts (2 NO + 2 NC) with rated operational current up to 70 A at 690 V. Business Impact: Enables robust motor and load control with reduced risk of contact wear and misoperation, lowering downtime in conveyors and pumps. Application: Industrial automation panels requiring reliable AC-1/AC-3 switching for moderate to heavy loads. Feature: Coil voltage options 175 V AC at 50 Hz and 208 V AC at 60 Hz. Business Impact: Simplifies control wiring by matching standard line frequencies, reducing mismatch errors and wiring complexity. Application: Control circuits in regions with 50/60 Hz supply, enabling seamless integration with existing PLCs and relays. Feature: Screw terminals for main and control circuits. Business Impact: Provides secure, vibration-resistant connections and straightforward field assembly, lowering maintenance time. Application: Cabinet wiring in process lines and packaging equipment where reliability matters. Feature: DIN rail mounting (TH35-15 or TH35-7.5). Business Impact: Fast, clean installation with minimal panel modification, improving deployment speed and serviceability. Application: New machine builds and retrofit projects inside control panels. Feature: Add-on auxiliary contact blocks and accessories compatibility. Business Impact: Extends signaling and interlock capabilities without replacing the base device, reducing total cost of ownership. Application: Complex control logic for multi-loop controls and safety circuits. Feature: IEC/UL approvals and EN standards compliance. Business Impact: Ensures regulatory conformity across markets, accelerating procurement cycles and supplier audits. Application: Global manufacturing environments with cross-border sourcing and compliance requirements.
Get a Quick Quote for a ABB 1SBL341501R3400
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL341501R3400?
Enquire Now
FAQs
Mount the device on a TH35-15 or TH35-7.5 DIN rail per IEC 60715. Use two M4 or two M6 screws diagonally for secure fixation. Connect the main circuit with flexible or rigid conductors in the 1/2x 4 to 35 mm² range, tightened to 4 N·m. For the control circuit, use 0.75 to 2.5 mm² conductors and tighten to 1.2 N·m. Ensure IP10 protection at main terminals and IP20 at coil terminals.
The coil supports 175 V AC at 50 Hz and 208 V AC at 60 Hz, enabling compatibility with common control schemes. This affects wiring by aligning the control supply with the specified coil voltage, reducing miswiring risk and preventing coil damage. Plan the control circuit accordingly and verify PLC or relay outputs match the 50/60 Hz coil requirements.
Yes, the AFC family is designed for extension with add-on auxiliary contact blocks and various accessories. Adding auxiliary contacts enhances signaling and interlocking in multi-loop or safety circuits without replacing the base device. This is particularly useful in conveyors, pumps, and machine controls where additional feedback is required for sequencing and protection.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, and carries CE, UKCA marks along with UL/CSA certifications. It also aligns with BV, CB, CCC, DNV, and RINA attestations, supporting regulatory conformity across markets and simplifying cross-border procurement and audits.
4-pole contactors reduce wiring complexity and enable reliable motor drives with fewer components, contributing to lower installation time and maintenance costs. With a robust 70 A at 690 V rating, long-term life is supported by appropriate control of inrush and switching frequency, while modular add-ons help tailor signaling and safety without frequent part replacements.