ABB 1SBL347001N1100 Block Contactor - IEC/EN 60947-4-1

Part Number: 1SBL347001N1100
Manufacturer
ABB
Part number
1SBL347001N1100

Quick Summary

The 1SBL347001N1100 Block Contactor by ABB is designed to reliably switch three‑phase motors up to 690 V in industrial control panels. Operators often contend with space constraints, complex wiring, and downtime; this compact 3‑pole design simplifies installation and reduces maintenance overhead. It complies with key standards such as IEC/EN 60947‑1, IEC/EN 60947‑4‑1, and UL/CSA listings, while RoHS and REACH declarations support safe, compliant operation. With DIN rail mounting options and robust terminal engineering, it scales easily for growing automation projects and helps you predict lifecycle costs more accurately.

Product Information

Extended Description

1SBL347001N1100 ABB: AF40N2 NEMA contactors are mainly used for controlling 3-phase motors and power circuits up to 600 VAC. These contactors are of the block type design with 3 main poles.
Minimum Order Quantity
1 piece
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
55 mm
Product Net Depth / Length
111 mm
Product Net Height
125.5 mm
Product Net Weight
0.97 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 60 A | (690 V) 40 °C 70 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE Category
Product Not in WEEE Scope
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09N ... AF80N NEMA contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09N ... AF80N NEMA contactors
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
97 mm
Package Level 1 Gross Weight
1.07 kg
Package Level 2 Units
10 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: 3 main NO contacts across 3 poles deliver reliable high‑current motor control for compact panel layouts, reducing footprint and wiring complexity in machine building and HVAC installations. Application: ideal for 3‑phase motors up to 600 VAC, enabling space‑efficient control within evolving manufacturing lines. Feature → Business Impact → Application: Rated Main Circuit up to 690 V supports broad voltage compatibility, easing changes to powered equipment and reducing rerouting costs in retrofit projects. Application: suitable for large conveyors and pumps in industrial plants that demand versatile voltage handling. Feature → Business Impact → Application: Control Circuit voltage range of 24–60 V (AC/DC) provides flexible PLC integration and simplifies stock management for spares. Application: plug‑and‑play control from standard PLC outputs without adapter complexity. Feature → Business Impact → Application: DIN rail mounting TH35‑15 or TH35‑7.5 enables fast, vibration‑resistant installation. Application: ideal for new enclosures or cabinet retrofits where quick deployment matters. Feature → Business Impact → Application: Screw terminals and defined conductor capacities streamline wiring and reduce commissioning time. Application: supports reliable terminations with both ferrule and rigid conductors in demanding environments. Feature → Business Impact → Application: Coil IP20 with main terminals IP10 delivers practical protection in control environments, improving safety margins in panel assemblies. Application: suitable for factory floors and control rooms with standard ambient conditions. Feature → Business Impact → Application: Comprehensive certification suite (UL/CSA/CE, IEC standards) lowers procurement risk and speeds compliance approvals. Application: supports regulated industries and multinational deployments with consistent safety benchmarks.

Get a Quick Quote for a ABB 1SBL347001N1100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL347001N1100? Enquire Now

FAQs

Install on a TH35‑15 or TH35‑7.5 DIN rail with the indicated 2 x M4 or M6 screws placed diagonally. Ensure main circuit wiring uses 1/2x 6..35 mm² conductors and control wiring uses 0.75..2.5 mm² as specified, then tighten to the recommended torque values for reliable operation.
For AC‑3, ratings include up to 40 A at 415–440 V and 25–40 A at 690 V depending on temperature and duration. For AC‑1, the device is rated up to 60 A at 60°C when used at 690 V. Always verify exact values for your motor case and ambient temperature.
Yes, it is designed for motor control up to 690 V and 3P operation, which covers many high‑inertia and driven HVAC applications. When selecting, confirm your motor’s starting current and duty cycle, and ensure the contactor’s Ie and Pu ratings meet or exceed those requirements.
The 1SBL347001N1100 carries IEC/EN 60947‑1 and 60947‑4‑1 marks, UL and CSA listings, and CE compliance. It also aligns with RoHS and REACH requirements, supporting global integration across regulated markets.
Key benefits include low per‑pole power loss (3 W AC‑1, 1 W AC‑3) which reduces heat and energy consumption, and robust screw‑terminal connections that lower commissioning time. The compact footprint and DIN rail mounting simplify replacements and upgrades, improving overall maintenance ROI.