ABB 1SBL347001N1200 Contactor - UL/CSA Certified

Part Number: 1SBL347001N1200
Manufacturer
ABB
Part number
1SBL347001N1200

Quick Summary

ABB 1SBL347001N1200 Contactor controls three‑phase motors in industrial power circuits. Engineers often struggle with space constraints, reliability, and regulatory compliance when upgrading motor starters. Certified to IEC/EN 60947-4-1, UL 60335-2-40, and CSA standards, this 3-pole block contactor delivers proven safety and performance for demanding environments. By combining compact DIN-rail mounting with robust insulation, screw terminals, and flexible coil voltage 48–130 V, it reduces installation time and wiring errors. The device is designed for 690 V main circuits and 50/60 Hz control, supporting reliable operation across a wide temperature and altitude range. This translates into lower maintenance costs and smoother plant operation for automated facilities.

Product Information

Extended Description

1SBL347001N1200 ABB: AF40N2 NEMA contactors are mainly used for controlling 3-phase motors and power circuits up to 600 VAC. These contactors are of the block type design with 3 main poles.
Minimum Order Quantity
1 piece
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
55 mm
Product Net Depth / Length
111 mm
Product Net Height
125.5 mm
Product Net Weight
0.97 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 60 A | (690 V) 40 °C 70 A | (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 40 A | (440 V) 60 °C 40 A | (500 V) 60 °C 35 A | (690 V) 60 °C 25 A | (380 / 400 V) 60 °C 40 A | (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Operational Power AC-3e (Pe)
(415 V) 22 kW | (440 V) 22 kW | (500 V) 22 kW | (690 V) 22 kW | (380 / 400 V) 18.5 kW | (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 3 W | at Rated Operating Conditions AC-3 per Pole 1 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE Category
Product Not in WEEE Scope
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09N ... AF80N NEMA contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09N ... AF80N NEMA contactors
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
97 mm
Package Level 1 Gross Weight
1.07 kg
Package Level 2 Units
10 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: 3-pole block contactor with 3 NO main contacts. Business Impact: enables reliable control of three‑phase motors up to 690 V main circuit, reducing risk of failed starts and downtime. Application: ideal for conveyors, pumps, and machine tools in automated lines. Feature: Coil voltage flexibility 48–130 V and 50/60 Hz control. Business Impact: simplifies wiring across varied control systems and minimizes stock keeping. Application: compatible with common industrial control panels and remote I/O configurations. Feature: DIN rail mounting TH35-15 or TH35-7.5 and screw terminals. Business Impact: faster installation and scalable cabinet design, lowering assembly time and labor costs. Application: panel builders and OEMs delivering compact, code-compliant installations. Feature: Compact dimensions and robust terminals (55 mm width, 111 mm depth, 125.5 mm height; IP20 coil terminals, IP10 main terminals). Business Impact: saves panel space while maintaining safe, reliable connections. Application: space-constrained control cabinets in manufacturing lines. Feature: Broad standards and sustainability footprint (IEC/EN 60947-4-1, UL 60335-2-40, CSA; RoHS/REACH compliance; EOL guidance). Business Impact: ensures regulatory compliance and easier end-of-life planning, reducing risk and total cost of ownership. Application: suitable for regulated industries and long lifecycle deployments.

Get a Quick Quote for a ABB 1SBL347001N1200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL347001N1200? Enquire Now

FAQs

This ABB contactor supports quick DIN-rail mounting on TH35-15 or TH35-7.5 rails, making it easy to drop into standard control panels. For sites requiring mechanical stability or non-rail installations, it also offers screw terminal connections for secure, field-terminated wiring. In practice, the combination reduces panel depth and simplifies revisions during commissioning.
AC‑1 ratings at 690 V allow up to 70 A at 60 °C (and 60 A at 60 °C for certain conditions), while AC‑3 ratings reach 40 A at 415–690 V with 60 °C ambient. AC‑3e ratings align with AC‑3 values, and rated power at 415–690 V is about 22 kW (AC‑3). These figures enable reliable motor starting and controlled switching for typical fan, pump, and compressor loads.
Yes. The 1SBL347001N1200 is designed for main-circuit voltages up to 690 V and control-circuit voltages in the 48–130 V range at 50/60 Hz. Its insulation, terminal design, and compliance with IEC/EN 60947-4-1 and UL/CSA standards support safe operation in industrial panels with diverse control voltages and high-energy demands.
The product complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40, UL 60947-1, UL 60947-4-1, and CSA standards, with additional UL/CSA listings and CE conformity. This broad certification set validates safety, electrical compatibility, and performance across North American and European regulatory frameworks, reducing risk when sourcing for global facilities.
The ABB 1SBL347001N1200 offers robust coil isolation, screw-terminal reliability, and DIN-rail mounting that minimize installation errors and maintenance downtime. With long‑term reliability in 40–70 °C environments and durable contact ratings, it supports lower replacement frequency and predictable total cost of ownership, aiding ROI in automated production lines.