ABB 1SBL351074R2600 Block Contactor - 690V CE/UL

Part Number: 1SBL351074R2600
Manufacturer
ABB
Part number
1SBL351074R2600

Quick Summary

ABB 1SBL351074R2600 Block Contactor is used to switch three‑phase motors and heavy power circuits up to 690 V. Maintaining uptime demands a device that matches coil voltage, thermal ratings, and regulatory compliance in a single package. This unit delivers a 3‑pole main circuit, AC‑operated control, and optional add‑on auxiliary blocks, backed by CE, UL, and RoHS declarations. Ith is rated 100 A in open air, with AC‑3 performance and a compact footprint that keeps panel space efficient. Choosing this ABB block contactor simplifies procurement and maintenance, supporting reliable operation across manufacturing lines. It also supports standard wiring with screw terminals and easy field installation, reducing commissioning time.

Product Information

Extended Description

1SBL351074R2600 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 50 A | (440 V) 55 °C 45 A | (500 V) 55 °C 45 A | (690 V) 55 °C 35 A | (380 / 400 V) 55 °C 50 A | (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW | (440 V) 25 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 105 V | 60 Hz 110 ... 127 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 5 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522403261
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Three main NO contacts and no NC contacts simplify motor control, reducing panel complexity and wiring time while delivering reliable 3‑phase switching for conveyors, pumps, and fans. The business impact is lower installation costs and improved reliability in demanding environments, with clear compatibility for AC‑3 duty at up to 690 V. The coil voltage is 105 V at 50 Hz and 110–127 V at 60 Hz, ensuring regional compatibility and flexible integration with common control circuits in automation panels across global sites. The device features a rated insulation voltage of 690 V and a thermal current (Ith) of 100 A, enabling robust performance in thermal environments and reducing the risk of nuisance trips during heavy load starts. With 5 W power loss per pole in AC‑1 and 1.3 W per pole in AC‑3, energy efficiency is improved and heat generation is kept within panel design limits. The compact footprint (82 mm wide, 110 mm deep, 108 mm high) and a weight of 1.05 kg support space‑constrained installations in machine control cabinets. Screw terminals simplify wiring and maintenance, while the option to add auxiliary contact blocks provides scalable control logic without replacing the base device. This combination aligns with industry standards and CAD workflows, streamlining spare parts planning and field upgrades for contract manufacturers and system integrators. The unit’s IP20 protection class and wide operating temperature range (-25 to 55 C with thermal overload relay) help ensure dependable performance in typical industrial environments and reduce the need for frequent maintenance. With 3 NO main contacts and no NC contacts, the AX50‑80A family’s modular design supports straightforward expansion and easier spare parts management, reducing total cost of ownership when upgrading legacy systems. The device’s documentation set, including a data sheet, CAD drawings, and installation instructions, accelerates the commissioning process and minimizes risk during startup. This makes the ABB contactor an ideal choice for panel builders seeking predictable performance and quick time‑to‑value in motor control applications.

Get a Quick Quote for a ABB 1SBL351074R2600

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL351074R2600? Enquire Now

FAQs

Install with the screw terminals provided for the main and control circuits. Ensure the coil voltage matches your supply (105 V at 50 Hz or 110–127 V at 60 Hz). Tighten control circuit terminals to 1 N·m and main circuit terminals to 4 N·m. If needed, add an auxiliary contact block to expand control logic, then verify IP20 protection and cooling conditions to prevent overheating.
The coil operates at 105 V for 50 Hz and 110–127 V for 60 Hz. This enables compatibility with regional control circuits in global installations, reducing the need for additional power converters or relays.
Rated operational current AC‑3 is up to 35 A at 690 V (55 °C) and up to 50–53 A at lower voltages per table. Maximum breaking capacity at 690 V is 630 A cos φ 0.45, enabling robust motor start‑up for common industrial loads.
Yes. The device carries CE and UL certifications with RoHS compliance, and ABB provides the associated DoCs and declarations to support manufacturer and safety compliance in international installations.
Product net width is 82 mm, depth 110 mm, and height 108 mm, with a net weight of 1.05 kg. The compact footprint supports easy installation in standard electrical enclosures and reduces panel space usage, beneficial for retrofit projects and compact machine designs.