ABB 1SBL351074R3600 Block Contactor - CE Declaration of Conformity
Part Number: 1SBL351074R3600
Quick Summary
Block Contactor ABB 1SBL351074R3600 delivers reliable motor control for 3‑phase drives up to 690 V. In demanding environments, coil voltage compatibility and downtime drive maintenance costs, so selecting the right control device matters. This unit carries CE conformity, UL/CSA recognition, and CCC certification, with IP20 coil terminals and IP10 main terminals to bolster safety and regulatory compliance. Built for the AX50–AX80 family, it streamlines installation, reduces spare parts complexity, and supports scalable motor-control strategies across multiple production lines.
Product Information
Extended Description
1SBL351074R3600 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 50 A | (440 V) 55 °C 45 A | (500 V) 55 °C 45 A | (690 V) 55 °C 35 A | (380 / 400 V) 55 °C 50 A | (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW | (440 V) 25 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V | 60 Hz 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 5 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522403360
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Three main contacts operated from an AC control circuit up to 690 V enables efficient three-phase motor control with minimized wiring complexity. Business impact: robust performance with reliable switching at high voltages, reducing unplanned downtime in conveying and pump applications. Applications: suitable for machines and processes requiring consistent AC-3 and AC-1 operation with 50/60 Hz control. The coil is available in 190 V at 50 Hz or 220 V at 60 Hz, simplifying control-system integration and improving reliability in mixed-voltage facilities. Features IP20 coil terminals and IP10 main terminals improve protection and ease of maintenance, especially during panel wiring and field service. This design provides a compact 70 mm width, 110 mm depth footprint and 108 mm height, enabling efficient panel layout and quicker installation in confined electrical cabinets. Power loss is rated at 5 W per pole (AC-1) and 1.3 W per pole (AC-3), contributing to cooler operation and better energy efficiency over long-running cycles. With screw-terminal connections, installation torque is straightforward at 1 N·m for the control circuit and 4 N·m for the main circuit, delivering secure, vibration-resistant connections in demanding environments. The device supports the AX50–AX80 power-contacting family, ensuring compatibility with a wide range of accessories and add-on blocks for auxiliary contacts and side mounting, reducing total cost of ownership and simplifying spare parts stocking.
Get a Quick Quote for a ABB 1SBL351074R3600
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL351074R3600?
Enquire Now
FAQs
Ensure proper wiring to the screw terminals, observe the coil voltage (190 V at 50 Hz or 220 V at 60 Hz), and verify IP20 coil terminals with IP10 main terminals. Tighten control circuit terminals to 1 N·m and main circuit terminals to 4 N·m, then test with a low-power trial run to confirm normal operation before full-load service.
For AC-1, Ie is up to 100 A at 690 V, and for AC-3, Ie ranges from 35–53 A depending on voltage (e.g., 50–53 A at 380–440 V, 45 A at 500–690 V). P_e ranges accordingly (e.g., up to 30 kW at 690 V). These ratings guide whether the device is suitable for running or starting larger motors in your line.
Yes, it is rated for 690 V main circuit operation with a rated insulation voltage of 690 V and a rated impulse withstand voltage of 6 kV on the auxiliary circuit. The device also offers IP20 protection at coil terminals and IP10 at main terminals, satisfying common industrial safety requirements.
The unit features CE conformity, UL/CSA listings, and CCC certificates, indicating compliance with European, North American, and Chinese safety standards. Additional RoHS and REACH declarations support environmental compliance, while the product’s WEEE B2B classification ensures appropriate end-of-life handling.
Plan panel layout to fit the 70 mm width and 110 mm depth footprint, group control and main wiring to minimize voltage drop, and stock compatible accessory blocks for add-on auxiliary contacts if your machine requires expanded control. Ensuring proper torque and secure screw-term connections reduces maintenance calls and extends service intervals.